Gravity Check Dam Spillway, Freeboard & Downstream Apron Calculator
Hydraulic layout calculator for gravity check dams with US customary inputs (cfs, ft). The calculation core applies the Taiwan Soil and Water Conservation Handbook (2017) §2.1 (trapezoidal spillway, freeboard and apron equations) and Technical Regulations Art. 65: it computes the sediment-laden design discharge, the overflow depth, freeboard, apron length, end sill height and sub-dam spacing, and checks the overflow depth against the handbook limit.
Standards and references (context for this calculation; the basis the calculator applies is the one stated below):
Design basis as reported by the calculation core: Taiwan Soil and Water Conservation Handbook (2017) §2.1 Eqs. 2.1.2–2.1.4, 2.1.46–2.1.50 (trapezoidal spillway, freeboard, apron); Taiwan Soil and Water Conservation Technical Regulations Art. 65
Recalculates in your browser as you edit inputs; Free sample Word report and DXF for this calculator; With a license: formal Word and DXF export, plus online project reports from the Project List.
Check Summary Preview (Software Format; Auto-Populated)
| Check item | Trial value | Status |
|---|---|---|
| Spillway Overflow Depth h | 1.484 m ≤ 3.0 m | OK |
Summary of the online calculation (software format) for checking by the designer and an independent checker. Final submittals require review and seal by the licensed Professional Engineer in responsible charge.
Desktop edition: calculation reports and cross-module quantity reconciliation
1. Calculation reports: with a license, the desktop edition writes Word (.docx) and Excel (.xlsx) calculation reports and DXF drawings without the trial watermark, listing the inputs, the equations used and the results; in trial mode the step-by-step detail is hidden. For this calculator alone, licensed users can also sign in on the calculator above and formally export a single-tool Word report (with a verification code) and DXF drawing. The Pro plan (all modules) is US$990 per year; see Pricing for monthly, perpetual and team plans.
2. Cross-module reconciliation: desktop project runs carry the design peak flow into downstream channel, culvert and bridge hydraulics; terrain cut/fill into the earthwork balance, cost and carbon tables; structural concrete, formwork and rebar take-off into the cost and carbon tables; slope and excavation safety-factor thresholds into construction monitoring trigger levels.
3. Agency plan reviewers and university faculty can request a complimentary review or teaching license (link below).
Governing Equations (US Customary Notation) & Basis Reported by the Calculation Core
The equations and limits the calculation core applies are listed below for independent checking.
Worked Example: 20-ft Effective Height Check Dam (Q_p = 1,000 cfs)
The worked example below was computed by the calculation core when this page was built; entering the same inputs above reproduces it. Verification cases, tolerances and actual differences for the calculation core are listed on the Benchmarks page.
Size the trapezoidal spillway overflow depth, freeboard and downstream apron length for a check dam (effective height 20 ft, total height 25 ft) on an 8.0% channel carrying a clear-water peak of 1,000 cfs with a 10% sediment allowance, spillway bottom width 30 ft and side slope 1:0.5.
Every number in this example was produced by the calculation core (WebAssembly) when this page was built. The calculation core works in SI units: the US customary inputs below are converted with exact NIST SP 811 factors before the calculation, and results are shown in US customary units with the core's SI value in parentheses. Check values, criteria and calculation steps are the core's own SI output. Basis reported by the core: Taiwan Soil and Water Conservation Handbook (2017) §2.1 Eqs. 2.1.2–2.1.4, 2.1.46–2.1.50 (trapezoidal spillway, freeboard, apron); Taiwan Soil and Water Conservation Technical Regulations Art. 65
1. Input Parameters
| Design Parameter | US Customary Value | Unit |
|---|---|---|
| Clear-Water Peak Flow Q_p | 1000 | cfs |
| Sediment Allowance α | 0.1 | — |
| Spillway Bottom Width b_o | 30 | ft |
| Spillway Side Slope Z (1:Z) | 0.5 | — |
| Channel Bed Slope S_o | 0.08 | m/m |
| Effective Dam Height H_e | 20 | ft |
| Total Dam Height H | 25 | ft |
| Sound Rock Foundation | No | — |
| Dam Body Stability Check | Not calculated | — |
2. Computed Results (calculation core output)
| Output | Result |
|---|---|
| Design Discharge Qd | 1100 cfs (31.149 m³/s) |
| Spillway Overflow Depth h | 4.868 ft (1.484 m) |
| Spillway Freeboard hf | 1.969 ft (0.600 m) |
| Downstream Apron Length L | 49.74 ft (15.16 m) |
Verification Checks (calculation core output)
| Verification Item | Computed Result | Governing Limit / Criterion | Status | Basis |
|---|---|---|---|---|
| Spillway Overflow Depth h | 1.484 m | ≤ 3.0 m | PASS | Taiwan Soil and Water Conservation Handbook (2017) §2.1 (p. 321) |
3. Calculation Steps (calculation core output, SI units)
[HyGeoWorks online preview - not for PE sealing or submittal] Design debris-laden peak discharge Qd = (1 + 0.1) × 28.3168 = 31.149 m³/s Trapezoidal spillway depth: Qd = 0.354·bu·(2 + 3χ)·h^1.5 → overflow depth h = 1.484 m, top width bu = 10.628 m, freeboard hf = 0.600 m Downstream apron length L = 15.16 m, end sill height = 1.22 m, sub-dam spacing = 11.37–15.16 m
US customary equivalents (NIST SP 811 conversion of the SI values reported by the core above; the core summary itself is unchanged) Design Discharge Qd = 1100 cfs Spillway Overflow Depth h = 4.868 ft Spillway Freeboard hf = 1.969 ft Downstream Apron Length L = 49.74 ft
Frequently Asked Questions (Basis, Scope & Limits)
Common questions about this calculator and its basis are answered below. Final submittals require review and seal by a licensed Professional Engineer.
Which design basis does this calculator follow?
The calculation core reports the Taiwan Soil and Water Conservation Handbook (2017) §2.1 (Eqs. 2.1.2–2.1.4 and 2.1.46–2.1.50) and the Taiwan Soil and Water Conservation Technical Regulations Art. 65. The inputs and results are shown in US customary units, but no US agency method (for example a debris-yield or debris-basin method) is applied; check against the requirements of your agency.
Does this web calculator check the stability of the dam body?
No — it sizes the spillway, freeboard and downstream apron only. The HydroStudio desktop edition includes gravity check-dam body stability (self-weight, water and sediment pressure, uplift, seismic forces, and debris-flow fluid force and boulder impact) per the Taiwan Soil and Water Conservation Technical Regulations Arts. 102–104 and the handbook §2.1.
Why should the wings rise toward the abutments with generous freeboard?
If debris or boulders partly block the spillway, flow overtopping the wings at the abutment contact can outflank and erode the dam. Keeping the flow in a recessed spillway notch with freeboard on the wings reduces this risk.
When is a sub-dam (counter-dam) used instead of a simple end sill?
A sub-dam creates a tailwater pool that submerges the jump below the main dam. The core reports the main-to-sub-dam spacing range of the handbook, (1.5 to 2.0) times (H_e + h); whether a sub-dam is needed depends on the bed material and the criteria of your agency.
From the Online Preview to the HydroStudio Desktop Edition: Reports Without the Trial Watermark
The free online preview is not for PE sealing or submittal and has no Word report, DXF drawing or verification code. Licensed users can sign in on the calculator and formally export a single-tool Word report (with a verification code) and DXF drawing. Several calculators can be combined in the Project List and exported online as a multi-chapter project report, and projects with terrain or GIS files can run in the heavy cloud computation. For interactive 2D models and large simulations, the HydroStudio desktop edition (Windows 10/11, 64-bit) opens the exported .toml project and, with a license, writes report.docx, a report.xlsx with live formulas and DXF drawings without the trial watermark. Sealing and submittal remain the responsibility of the licensed engineer.