HyGeoWorks
🔒 Previews run in your browser (WebAssembly) · Inputs are sent only when you formally export
FHWA HEC-18 Scour · Taiwan Freeboard Classes · SI Units

Bridge Crossing: Backwater and Scour

Pier backwater (Yarnell), flow-area obstruction ratio, low-chord freeboard, contraction scour (live-bed and clear-water), local pier scour (with skew and woody-debris equivalent pier width), maximum probable scour depth, stream pressure on piers and riprap at piers.

Design basis for this page ▾
FHWA HEC-18 5th Ed. (2012) Eqs. 6.1–6.4, 7.1–7.4, 7.32, 7.34; HEC-RAS Hydraulic Reference Manual Eq. 5-4 (Yarnell); FHWA HEC-23 Design Guideline 11

Design basis as reported by the calculation core: FHWA HEC-18 5th Ed. (2012) Eqs. 6.1–6.4, 7.1–7.4, 7.32, 7.34; HEC-RAS Hydraulic Reference Manual Eq. 5-4 (Yarnell); FHWA HEC-23 Design Guideline 11
Scour and backwater are computed with the FHWA equations named in the basis line. The low-chord freeboard classes in the input list and the obstruction-ratio note in the results are Taiwan rules; check the requirements of your own authority separately.

Recalculates in your browser as you edit inputs; Free sample Word report and DXF for this calculator; With a license: formal Word and DXF export, plus online project reports from the Project List.

Interactive Engineering Workstation (SI Units, Reference Calculation)
SI units (reference calculation)
Free Samples and Pricing
A public sample produced by the production service from this page's standard example and sealed with a verification code: open it in Word or AutoCAD and check it on the Verify page. Not for PE sealing or submittal.
Single-export pass: US$19 for one calculator, 3 formal exports in total within 24 hours of the first; full credit toward an upgrade within 30 days, full refund before the first export
Single-export passes (one calculator, 3 exports within 24 hours), 30-day passes, annual plans and perpetual licenses; printable quotes for purchase orders.
Formal export and the Project List are on the workbench toolbar above:
Licensed users can formally export this calculator's Word report (with a verification code and server time witness) and AutoCAD DXF drawing, or add several calculators to the free Project List and export a multi-chapter project report online, with nothing to install on a Mac. Projects with DEM terrain or GIS files can run in the heavy cloud computation or in the HydroStudio desktop edition.
The summary lists the basis, key results and check verdicts; its first line marks it as an online preview, not for PE sealing or submittal.
Download the Offline Workbench (Single HTML File, 39 Tools)
No install and no email required. It contains the same calculation core as this site; results are also a preview, not for sealed submittals.

Check Summary Preview (Software Format; Auto-Populated)

Bridge Crossing: Backwater and Scour: check summary (software format)
Calculation basis: FHWA HEC-18 5th Ed. (2012) Eqs. 6.1–6.4, 7.1–7.4, 7.32, 7.34; HEC-RAS Hydraulic Reference Manual Eq. 5-4 (Yarnell); FHWA HEC-23 Design Guideline 11
Check item Trial value Status
Pier backwater0.020 mCalculated value
Flow area obstruction ratio5.0 %Calculated value
Contraction scour depth0.00 mCalculated value
Local pier scour depth (max)3.47 mCalculated value

Summary of the online calculation (software format) for checking by the designer and an independent checker. Final submittals require review and seal by the licensed Professional Engineer in responsible charge.

Desktop edition: calculation reports and cross-module quantity reconciliation

1. Calculation reports: with a license, the desktop edition writes Word (.docx) and Excel (.xlsx) calculation reports and DXF drawings without the trial watermark, listing the inputs, the equations used and the results; in trial mode the step-by-step detail is hidden. For this calculator alone, licensed users can also sign in on the calculator above and formally export a single-tool Word report (with a verification code) and DXF drawing. The Pro plan (all modules) is US$990 per year; see Pricing for monthly, perpetual and team plans.
2. Cross-module reconciliation: desktop project runs carry the design peak flow into downstream channel, culvert and bridge hydraulics; terrain cut/fill into the earthwork balance, cost and carbon tables; structural concrete, formwork and rebar take-off into the cost and carbon tables; slope and excavation safety-factor thresholds into construction monitoring trigger levels.
3. Agency plan reviewers and university faculty can request a complimentary review or teaching license (link below).

Desktop pricing (Pro US$990/yr) Download the desktop trial Complimentary license for agency reviewers and faculty
Scope and responsibility: This page is a single-calculator trial run; cross-module quantity reconciliation is done in desktop project runs. Problems outside this calculator's scope (see the FAQ) need an appropriate analysis method. Final submittals require review and seal by a licensed Professional Engineer. Federal public-domain datasets cited pursuant to 17 U.S.C. § 105 (FHWA HEC-18, FHWA HEC-23; no official U.S. Government endorsement implied). Backwater at a bridge in a regulatory floodway is subject to 44 CFR 60.3(d)(3) (no increase in base flood levels); this calculator reports the backwater but is not a floodway analysis. The scour condition rating (NBI Item 113) is assigned by the engineers under the FHWA coding guide and is not computed by this calculator.

Standard example (calculation core defaults)

The worked example below was computed by the calculation core when this page was built; entering the same inputs above reproduces it. Verification cases, tolerances and actual differences for the calculation core are listed on the Benchmarks page.

The standard example uses the default inputs of the calculation core. Every number below was produced by the core when this page was built; nothing on this page is computed by hand.

Every number in this example was produced by the calculation core (WebAssembly) when this page was built. This calculator computes to the documents named in its basis line and works in SI units; use the unit button in the calculator to view US customary equivalents. Basis reported by the core: FHWA HEC-18 5th Ed. (2012) Eqs. 6.1–6.4, 7.1–7.4, 7.32, 7.34; HEC-RAS Hydraulic Reference Manual Eq. 5-4 (Yarnell); FHWA HEC-23 Design Guideline 11

1. Input Parameters

Design ParameterValueUnit
Design Discharge Q600cms
River Width at Bridge B80m
Flow Depth at Bridge y3.5m
Upstream Main Channel Width W1(blank)m
Upstream Approach Depth y1(blank)m
Flow Angle of Attack0°
Pier Width a2m
Pier Length L8m
Pier Nose ShapeRound nose—
Number of Piers in Channel2—
Yarnell Pier TypeFrom pier nose shape (conservative value where no unique match)—
Pier Riprap Velocity Adjustment Factor K2(blank)—
Minimum Pier Centre Spacing(blank)m
Woody Debris on PierNot considered—
Bed Material D5030mm
Bed Material D84(blank)mm
Bed ConditionPlane bed and antidune flow 1.1—
Upstream Energy Slope S1(blank)—
Fall Velocity of D50, T(blank)m/s
Long-Term Bed Degradation1m
Mobile Bed Layer Thickness0m
Low Chord Height(blank)m
River ClassTaiwan central / special-municipality rivers 1.5 m—
Custom Minimum Low-Chord Clearance(blank)m
Flow Area Obstruction Ratio Limit(blank)%
Reach Freeboard Fb(blank)m
Pier Backwater AnalysisOne-dimensional analysis (Yarnell backwater)—
Foundation Embedment(blank)m
Falsework in Flood SeasonNo—
Cumulative Falsework Width(blank)m
River Width(blank)m

2. Computed Results (calculation core output)

OutputResult
Pier backwater0.020 m
Flow area obstruction ratio5.0 %
Contraction scour depth0.00 m
Local pier scour depth (max)3.47 m
Maximum probable scour depth4.47 m

3. Calculation Steps (calculation core output, SI units)

[HyGeoWorks online preview - not for PE sealing or submittal]
Velocity at bridge V = 2.14 m/s, Froude number Fr = 0.37, velocity head 0.234 m
Total projected pier width 4.00 m; flow area obstruction ratio 5.0%; backwater 0.020 m (Yarnell); upstream depth after bridging 3.52 m
Approach velocity V1 = 2.14 m/s, critical velocity Vc = 2.37 m/s → clear-water scour
Contraction scour: live-bed y2 = 3.63 m (k1 = 0.69)→ 0.13 m; clear-water y2 = 3.09 m → 0.00 m; adopted 0.00 m
Maximum probable scour depth = long-term 1.00 + mobile layer 0.00 + contraction 0.00 + local 3.47 = 4.47 m
Local pier scour (HEC-18 Eq. 7.1) (1 rows)
NosePier width a (m)Effective width (m)K1K2K3ys (m)Rule-of-thumb limit (m)Coarse-bed eq. (m)KwScour hole top width each side (m)
Round-nose pier2.002.001.001.0001.103.474.80——6.95
Stream pressure and pier riprap (1 rows)
NoseStream pressure resultant (kN)Height of action (m)Riprap K2Riprap d50 (m)Extent (m)Thickness (m)
Round-nose pier11.72.351.700.6384.001.91

Assumptions and Limits Stated by the Calculation Core

Frequently Asked Questions

Common questions about this calculator and its basis are answered below. Final submittals require review and seal by a licensed Professional Engineer.

Which design basis does this calculator apply?

FHWA HEC-18 5th Ed. (2012) Eqs. 6.1–6.4, 7.1–7.4, 7.32, 7.34; HEC-RAS Hydraulic Reference Manual Eq. 5-4 (Yarnell); FHWA HEC-23 Design Guideline 11. Scour and backwater are computed with the FHWA equations named in the basis line. The low-chord freeboard classes in the input list and the obstruction-ratio note in the results are Taiwan rules; check the requirements of your own authority separately.

What assumptions and limits does the calculation core state for this tool?

Platform scour screening hint (not an official FHWA NBI Item 113 code): Item 113 must be coded by hydraulic, geotechnical and structural engineers from a scour analysis under the FHWA Recording and Coding Guide (FHWA-PD-96-001), which defines the codes descriptively (for example 8: calculated scour is above top of footing; 5: scour within limits of footing or piles and foundations stable; 3: scour critical, foundations unstable; U: unknown foundation) and gives no numeric depth thresholds. This platform therefore outputs no code and makes no pass/fail judgement. Calculated total scour depth 4.47 m; foundation embedment depth not provided. Pier riprap: where the velocity adjustment factor K2 for the pier location is not given, the upper bound 1.7 of the HEC-23 DG 11 Eq. 11.2 range is used (main current around a sharp bend; conservative). It may be as low as 0.9 for a pier near the bank in a straight reach; enter riprap_k2 according to the pier location in the channel. The minimum pier riprap thickness is the greatest of 3·d50, contraction scour plus long-term degradation, and the bedform trough depth (HEC-23 DG 11 §11.6.1, Fig. 11.15); increase the thickness by 50% where placed under water, and provide a filter beneath the riprap (geotextile extending over 2/3 of the riprap extent). No abutments entered: local abutment scour was not checked in this run, and the results do not indicate that the abutment foundations have been checked. Where an abutment is in or near the main channel, or the embankment obstructs overbank flow, enter the abutment data for a check per HEC-18 Chapter 8. Flow area obstruction ratio 5.0% (projected pier width 4.00 m). MOTC (Taiwan) Highway Drainage Design Code (2018) 7.4 only requires spans as long as practicable to reduce obstruction and sets no numeric limit; the Taiwan Directions for Reviewing River-Crossing Structures (amended 2024-01-09) define the flow area obstruction ratio in Point 2(11) without a limit, and the 7% in the former notice was a condition for omitting the hydraulic analysis that the current directions have deleted, so the ratio is listed only. Hydraulics use an equivalent rectangular section at the bridge; the Yarnell equation reflects pier losses only, without abutment contraction or approach embankments (where abutments clearly contract the channel, use a multi-section energy or momentum analysis). Long-term bed degradation and mobile bed layer thickness are input values.

Where is the calculation performed, and can the result be sealed or submitted?

The calculation runs in your browser, in the same WebAssembly calculation core this page loads. The result is an online preview: its first line reads "[HyGeoWorks online preview - not for PE sealing or submittal]".

Can I recalculate without a network connection?

Yes. "Download the offline workbench" on this page saves one HTML file that contains the workbench and the same calculation core; opened from disk it recalculates without a network connection.

USD Pricing · Checkout by Stripe · Printable USD Quotation

From the Online Preview to the HydroStudio Desktop Edition: Reports Without the Trial Watermark

The free online preview is not for PE sealing or submittal and has no Word report, DXF drawing or verification code. Licensed users can sign in on the calculator and formally export a single-tool Word report (with a verification code) and DXF drawing. Several calculators can be combined in the Project List and exported online as a multi-chapter project report, and projects with terrain or GIS files can run in the heavy cloud computation. For interactive 2D models and large simulations, the HydroStudio desktop edition (Windows 10/11, 64-bit) opens the exported .toml project and, with a license, writes report.docx, a report.xlsx with live formulas and DXF drawings without the trial watermark. Sealing and submittal remain the responsibility of the licensed engineer.

Monthly
Pro monthly
$119 / month
One discipline: $69 / month. Renews monthly until canceled; cancel any time before the next renewal and keep using it to the end of the paid month.
Buy monthly ($119/mo)
30 days
30-day pass
$79 / 30 days, one discipline
All modules: $135. One payment; it does not renew. The pass fee can be credited once toward an annual or perpetual license of the same discipline or a higher plan bought within 30 days after the pass ends, with the same email and in the same currency.
Buy a 30-day pass (from $79)
Quotation
Printable USD quotation
For any plan, including Firm (from 3 seats) and Enterprise (from 10 seats), which are sold only to businesses and other organizations, not to individual buyers: print the quotation or save it as a PDF for your purchasing process.
Request a printable USD quotation

Compare all plans, including 90-day passes and perpetual licenses

Checkout is processed by Stripe; a tax ID can be entered at checkout, and for one-time payments Stripe issues an invoice showing the buyer's name and tax ID. Procurement follows your organization's own rules.

Explore All 31 Tools (20 US Customary + 11 Reference: Basis Stated on Each Page)

Need to edit terrain, 2D flood models and design alternatives interactively on your computer, or see 3D views drawn from your project data? Use the HydroStudio desktop edition:
Download the Desktop Trial
No credit card or phone number is needed to download. Without a license it runs as a trial: local calculation and 3D viewing work, exported reports and drawings carry a trial watermark (not for submittal), and some built-in data libraries are limited. Plans and prices are on the Pricing page.