Circular Slope Stability Calculator — USACE EM 1110-2-1902 & Simplified Bishop Method
Automated circular slip-surface grid search using Bishop's Simplified Method of Slices with US customary inputs (ft, pcf, psf); the calculation core compares the minimum factor of safety with USACE EM 1110-2-1902 Table 3-1 (long-term steady seepage) as an advisory reference. Verification cases of the calculation core are listed on the Benchmarks page.
Standards and references (context for this calculation; the basis the calculator applies is the one stated below):
Design basis as reported by the calculation core: USACE EM 1110-2-1902 Table 3-1
Recalculates in your browser as you edit inputs; Free sample Word report and DXF for this calculator; With a license: formal Word and DXF export, plus online project reports from the Project List; 3D schematic: fixed example, not drawn from your inputs.
Check Summary Preview (Software Format; Auto-Populated)
| Check item | Trial value | Status |
|---|---|---|
| Slope Factor of Safety (Long-Term (steady seepage / in service)) | 1.993 ≥ 1.500 | ◇ Not judged Not judged: The selected code treats this item as advisory, so no pass/fail judgement is made; the reference comparison is met. |
Summary of the online calculation (software format) for checking by the designer and an independent checker. Final submittals require review and seal by the licensed Professional Engineer in responsible charge.
Desktop edition: calculation reports and cross-module quantity reconciliation
1. Calculation reports: with a license, the desktop edition writes Word (.docx) and Excel (.xlsx) calculation reports and DXF drawings without the trial watermark, listing the inputs, the equations used and the results; in trial mode the step-by-step detail is hidden. For this calculator alone, licensed users can also sign in on the calculator above and formally export a single-tool Word report (with a verification code) and DXF drawing. The Pro plan (all modules) is US$990 per year; see Pricing for monthly, perpetual and team plans.
2. Cross-module reconciliation: desktop project runs carry the design peak flow into downstream channel, culvert and bridge hydraulics; terrain cut/fill into the earthwork balance, cost and carbon tables; structural concrete, formwork and rebar take-off into the cost and carbon tables; slope and excavation safety-factor thresholds into construction monitoring trigger levels.
3. Agency plan reviewers and university faculty can request a complimentary review or teaching license (link below).
Governing Equations (US Customary Notation) & Basis Reported by the Calculation Core
The equations and limits the calculation core applies are listed below for independent checking.
Worked Example: 30.0-ft Embankment (2H:1V) Long-Term Steady Seepage Stability
The worked example below was computed by the calculation core when this page was built; entering the same inputs above reproduces it. Verification cases, tolerances and actual differences for the calculation core are listed on the Benchmarks page.
Evaluate the minimum circular-slip factor of safety for an H = 30.0 ft compacted embankment sloped at 2H:1V (γ = 120 pcf, γ_sat = 130 pcf, c' = 250 psf, φ' = 30°) with a steady-seepage phreatic surface at 6.0 ft above the toe level at the crest.
Every number in this example was produced by the calculation core (WebAssembly) when this page was built. The calculation core works in SI units: the US customary inputs below are converted with exact NIST SP 811 factors before the calculation, and results are shown in US customary units with the core's SI value in parentheses. Check values, criteria and calculation steps are the core's own SI output. Basis reported by the core: USACE EM 1110-2-1902 Table 3-1
1. Input Parameters
| Design Parameter | US Customary Value | Unit |
|---|---|---|
| Slope Height H | 30 | ft |
| Side Slope Ratio m (mH:1V) | 2 | — |
| Moist Unit Weight γ | 120 | pcf |
| Saturated Unit Weight γ_sat | 130 | pcf |
| Effective Cohesion c' | 250 | psf |
| Effective Friction Angle φ' | 30 | ° |
| Crest Water Table Height h_w (above Toe) | 6 | ft |
| Pseudo-Static Seismic Coefficient k_h | 0 | — |
| Method | Simplified Bishop | — |
| Design Situation / Stage | Permanent / Long-Term | — |
| Loading Condition | Normal | — |
2. Computed Results (calculation core output)
| Output | Result |
|---|---|
| Minimum Factor of Safety FS | 1.993 |
| Critical Circle Center xc | 75 ft (22.86 m) |
| Critical Circle Center zc | 49.5 ft (15.09 m) |
| Slip Circle Radius R | 56.36 ft (17.18 m) |
Verification Checks (calculation core output)
| Verification Item | Computed Result | Governing Limit / Criterion | Status | Basis |
|---|---|---|---|---|
| Slope Factor of Safety (Long-Term (steady seepage / in service)) | 1.993 | ≥ 1.500 | ◇ Not judged Not judged: The selected code treats this item as advisory, so no pass/fail judgement is made; the reference comparison is met. | USACE EM 1110-2-1902 Table 3-1 |
3. Calculation Steps (calculation core output, SI units)
[HyGeoWorks online preview - not for PE sealing or submittal] Toe x = 18.3 m, Crest x = 36.6 m; Search grid xc [13.7, 41.1], zc [11.0, 27.4], evaluated 901 slip circles Critical circle: center (22.86, 15.09) m, R = 17.18 m; entry x = 14.65 m, exit x = 38.98 m, characteristic FS = 1.993
US customary equivalents (NIST SP 811 conversion of the SI values reported by the core above; the core summary itself is unchanged) Critical Circle Center xc = 75 ft Critical Circle Center zc = 49.5 ft Slip Circle Radius R = 56.36 ft
Method of Slices Summary (30 rows)
| # | x (m) | α (°) | W (kN/m) | u·l | N' | S | c'l + N'tanφ' | z_base | z_top | b (m) |
|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 15.05 | -27.03 | 3.54 | 1.91 | 5.70 | 7.12 | 14.19 | -0.214 | 0.000 | 0.811 |
| 2 | 15.86 | -24.03 | 9.95 | 5.24 | 9.23 | 8.01 | 15.96 | -0.601 | 0.000 | 0.811 |
| 3 | 16.68 | -21.10 | 15.54 | 8.00 | 12.01 | 8.70 | 17.34 | -0.938 | 0.000 | 0.811 |
| 4 | 17.49 | -18.23 | 20.34 | 10.28 | 14.17 | 9.23 | 18.40 | -1.228 | 0.000 | 0.811 |
| 5 | 18.30 | -15.40 | 24.47 | 12.16 | 15.87 | 9.65 | 19.23 | -1.473 | 0.005 | 0.811 |
| 6 | 19.11 | -12.62 | 34.12 | 14.33 | 23.26 | 11.73 | 23.38 | -1.675 | 0.410 | 0.811 |
| 7 | 19.92 | -9.86 | 43.09 | 16.15 | 29.96 | 13.62 | 27.15 | -1.836 | 0.816 | 0.811 |
| 8 | 20.73 | -7.12 | 51.40 | 17.65 | 36.06 | 15.35 | 30.60 | -1.958 | 1.221 | 0.811 |
| 9 | 21.54 | -4.40 | 59.05 | 18.87 | 41.67 | 16.95 | 33.79 | -2.039 | 1.627 | 0.811 |
| 10 | 22.35 | -1.69 | 66.07 | 19.81 | 46.83 | 18.44 | 36.75 | -2.083 | 2.032 | 0.811 |
| 11 | 23.16 | 1.01 | 72.45 | 20.49 | 51.63 | 19.83 | 39.51 | -2.087 | 2.438 | 0.811 |
| 12 | 23.97 | 3.72 | 78.20 | 20.91 | 56.08 | 21.13 | 42.11 | -2.054 | 2.843 | 0.811 |
| 13 | 24.78 | 6.43 | 83.31 | 21.07 | 60.25 | 22.35 | 44.55 | -1.982 | 3.248 | 0.811 |
| 14 | 25.60 | 9.16 | 87.77 | 20.96 | 64.15 | 23.52 | 46.87 | -1.871 | 3.654 | 0.811 |
| 15 | 26.41 | 11.92 | 91.57 | 20.58 | 67.81 | 24.62 | 49.07 | -1.720 | 4.059 | 0.811 |
| 16 | 27.22 | 14.70 | 94.70 | 19.91 | 71.25 | 25.68 | 51.17 | -1.528 | 4.465 | 0.811 |
| 17 | 28.03 | 17.51 | 97.12 | 18.92 | 74.50 | 26.69 | 53.19 | -1.294 | 4.870 | 0.811 |
| 18 | 28.84 | 20.37 | 98.82 | 17.57 | 77.56 | 27.66 | 55.14 | -1.016 | 5.276 | 0.811 |
| 19 | 29.65 | 23.29 | 99.74 | 15.82 | 80.45 | 28.61 | 57.01 | -0.691 | 5.681 | 0.811 |
| 20 | 30.46 | 26.27 | 99.84 | 13.61 | 83.16 | 29.52 | 58.84 | -0.317 | 6.087 | 0.811 |
| 21 | 31.27 | 29.32 | 99.06 | 10.84 | 85.70 | 30.41 | 60.61 | 0.111 | 6.492 | 0.811 |
| 22 | 32.08 | 32.48 | 97.33 | 7.39 | 88.07 | 31.29 | 62.35 | 0.596 | 6.898 | 0.811 |
| 23 | 32.89 | 35.74 | 94.53 | 3.09 | 90.25 | 32.14 | 64.06 | 1.146 | 7.303 | 0.811 |
| 24 | 33.71 | 39.15 | 90.84 | 0.00 | 90.64 | 32.54 | 64.85 | 1.767 | 7.709 | 0.811 |
| 25 | 34.52 | 42.73 | 86.28 | 0.00 | 87.83 | 32.07 | 63.93 | 2.470 | 8.114 | 0.811 |
| 26 | 35.33 | 46.53 | 80.24 | 0.00 | 83.62 | 31.30 | 62.39 | 3.271 | 8.520 | 0.811 |
| 27 | 36.14 | 50.62 | 72.39 | 0.00 | 77.42 | 30.10 | 60.00 | 4.190 | 8.925 | 0.811 |
| 28 | 36.95 | 55.11 | 59.36 | 0.00 | 64.69 | 27.25 | 54.32 | 5.261 | 9.144 | 0.811 |
| 29 | 37.76 | 60.16 | 39.80 | 0.00 | 41.81 | 21.90 | 43.65 | 6.540 | 9.144 | 0.811 |
| 30 | 38.57 | 66.15 | 15.31 | 0.00 | 6.41 | 13.90 | 27.71 | 8.143 | 9.144 | 0.811 |
Assumptions and Limits Stated by the Calculation Core
- USACE EM 1110-2-1902 Table 3-1 gives minimum factors of safety for new embankment dams; per §3-1b(2) they are advisory for existing dams and other slopes, so this judgement is for reference only.
USACE EM 1110-2-1902 Table 3-1 Minimum Required Factors of Safety (New Earth and Rock-Fill Dams)
Inputs and outputs are listed with their units; conversion to and from SI is done by the calculation core.
| USACE Loading Condition | Applicable Slope | Minimum Required FS | Use on This Page |
|---|---|---|---|
| End-of-Construction (including staged construction) | Upstream & Downstream | 1.3 | Reference value (not checked) |
| Long-Term (Steady Seepage, Maximum Storage Pool) | Downstream | 1.5 | Checked by the calculation core |
| Maximum Surcharge Pool | Downstream | 1.4 | Reference value (not checked) |
| Rapid Drawdown (from Maximum Storage Pool / from Maximum Surcharge Pool) | Upstream | 1.3 / 1.1 | Reference value (not checked) |
Frequently Asked Questions (Basis, Scope & Limits)
Common questions about this calculator and its basis are answered below. Final submittals require review and seal by a licensed Professional Engineer.
How does Simplified Bishop compare with rigorous methods for circular slip surfaces?
For circular slip surfaces the Simplified Bishop method, which satisfies moment equilibrium and vertical force equilibrium of the slices, generally gives factors of safety close to methods that satisfy full equilibrium (Spencer, Morgenstern–Price), while the Ordinary Method of Slices tends to be conservative where pore pressures are high. The HydroStudio desktop edition includes Spencer, Morgenstern–Price and Janbu solutions for comparison.
How is the critical slip circle searched?
The calculation core searches a grid of circle centers and radii over a range it sets from the slope geometry (the range is not an input; the calculation steps list the grid and the number of circles evaluated) and reports the circle with the minimum factor of safety. The HydroStudio desktop edition adds user-defined search ranges and a minimum slip-depth filter that screens out shallow surface raveling on cohesionless slopes.
How does USACE 'rapid drawdown' differ from storm rainfall infiltration?
Rapid drawdown applies to submerged upstream slopes of reservoirs or detention basins when the external water level drops faster than internal pore pressures can dissipate (USACE Table 3-1 lists FS 1.1 to 1.3 for drawdown conditions). It is not checked on this page. For slopes above water exposed to intense rainfall, use the Green–Ampt infinite slope calculator or a 2D seepage analysis.
Does the HydroStudio desktop edition support non-circular slip surfaces and slope reinforcement?
Yes. The HydroStudio desktop edition supports multi-layer stratigraphy, Spencer, Morgenstern–Price and Janbu solutions with general (non-circular) slip surfaces, and reinforcement by ground anchors, soil nails, geosynthetic reinforcement and stabilizing piles. Open the model through 'Export .toml' and complete the fields marked as placeholders.
From the Online Preview to the HydroStudio Desktop Edition: Reports Without the Trial Watermark
The free online preview is not for PE sealing or submittal and has no Word report, DXF drawing or verification code. Licensed users can sign in on the calculator and formally export a single-tool Word report (with a verification code) and DXF drawing. Several calculators can be combined in the Project List and exported online as a multi-chapter project report, and projects with terrain or GIS files can run in the heavy cloud computation. For interactive 2D models and large simulations, the HydroStudio desktop edition (Windows 10/11, 64-bit) opens the exported .toml project and, with a license, writes report.docx, a report.xlsx with live formulas and DXF drawings without the trial watermark. Sealing and submittal remain the responsibility of the licensed engineer.
Compare all plans, including 90-day passes and perpetual licenses