Pile Cap Shear and Reinforcement
Pile reactions of a rigid cap, moments at the column face and two-way bottom reinforcement, one-way shear, two-way shear around the column (including moment transfer), punching by a single pile, and bar development.
Design basis as reported by the calculation core: Taiwan Design Code for Concrete Structures (2023; ACI 318-19 framework) Arts. 13.4.6, 13.2.7, 22.5, 22.6 (Table 22.6.5.2), 8.4.4.2, 25.4
Design follows the Taiwan concrete code named in the basis line (ACI 318-19 framework). This calculator covers the pile cap only; it does not compute a P–M interaction diagram for the piles. Bar sizes are D13–D32 and strengths are entered in kgf/cm².
Recalculates in your browser as you edit inputs; Free sample Word report and DXF for this calculator; With a license: formal Word and DXF export, plus online project reports from the Project List.
Check Summary Preview (Software Format; Auto-Populated)
| Check item | Trial value | Status |
|---|---|---|
| x-direction bottom steel flexure (section at column face) | 1613.2 kN·m ≥ 1200.0 | OK |
| x-direction bottom steel development (column face to bar end) | 112.5 cm ≥ 72.6 | OK |
| y-direction bottom steel flexure (section at column face) | 1574.6 kN·m ≥ 1200.0 | OK |
| y-direction bottom steel development (column face to bar end) | 112.5 cm ≥ 72.6 | OK |
| x-direction one-way shear (at d = 81.5 cm) | 570.8 kN ≥ 281.8 | OK |
| x-direction shear limit at column face (piles within d of the face) | 7978.6 kN ≥ 2000.0 | OK |
Summary of the online calculation (software format) for checking by the designer and an independent checker. Final submittals require review and seal by the licensed Professional Engineer in responsible charge.
Desktop edition: calculation reports and cross-module quantity reconciliation
1. Calculation reports: with a license, the desktop edition writes Word (.docx) and Excel (.xlsx) calculation reports and DXF drawings without the trial watermark, listing the inputs, the equations used and the results; in trial mode the step-by-step detail is hidden. For this calculator alone, licensed users can also sign in on the calculator above and formally export a single-tool Word report (with a verification code) and DXF drawing. The Pro plan (all modules) is US$990 per year; see Pricing for monthly, perpetual and team plans.
2. Cross-module reconciliation: desktop project runs carry the design peak flow into downstream channel, culvert and bridge hydraulics; terrain cut/fill into the earthwork balance, cost and carbon tables; structural concrete, formwork and rebar take-off into the cost and carbon tables; slope and excavation safety-factor thresholds into construction monitoring trigger levels.
3. Agency plan reviewers and university faculty can request a complimentary review or teaching license (link below).
Standard example (calculation core defaults)
The worked example below was computed by the calculation core when this page was built; entering the same inputs above reproduces it. Verification cases, tolerances and actual differences for the calculation core are listed on the Benchmarks page.
The standard example uses the default inputs of the calculation core. Every number below was produced by the core when this page was built; nothing on this page is computed by hand.
Every number in this example was produced by the calculation core (WebAssembly) when this page was built. This calculator computes to the documents named in its basis line and works in SI units; use the unit button in the calculator to view US customary equivalents. Basis reported by the core: Taiwan Design Code for Concrete Structures (2023; ACI 318-19 framework) Arts. 13.4.6, 13.2.7, 22.5, 22.6 (Table 22.6.5.2), 8.4.4.2, 25.4
1. Input Parameters
| Design Parameter | Value | Unit |
|---|---|---|
| Piles in x Direction | 2 | — |
| Piles in y Direction | 2 | — |
| Pile Spacing in x (centre to centre) | 1.8 | m |
| Pile Spacing in y (centre to centre) | 1.8 | m |
| Pile Diameter | 0.6 | m |
| Outermost Pile Centre to Cap Edge | 0.6 | m |
| Cap Thickness | 1 | m |
| Pile Head Embedment into Cap | 0.1 | m |
| Column Dimension in x | 0.6 | m |
| Column Dimension in y | 0.6 | m |
| Concrete Strength f'c | 280 | kgf/cm² |
| Rebar Yield Strength fy | 4200 | kgf/cm² |
| Bottom Bar Size | Selected by program | — |
| Factored Column Axial Load Pu | 4000 | kN |
| Factored Moment Mux | 0 | kN·m |
| Factored Moment Muy | 0 | kN·m |
2. Computed Results (calculation core output)
| Output | Result |
|---|---|
| Max factored pile reaction | 1000.0 kN |
| Max utilization (demand / capacity) | 0.814 |
| Concrete | 9.00 m³ |
| Bottom steel weight | 244 kg |
Verification Checks (calculation core output)
| Verification Item | Computed Result | Governing Limit / Criterion | Status | Basis |
|---|---|---|---|---|
| x-direction bottom steel flexure (section at column face) | 1613.2 kN·m | ≥ 1200.0 | PASS | Taiwan Design Code for Concrete Structures (2023) Art. 13.4.6.2, Table 13.2.7.1 |
| x-direction bottom steel development (column face to bar end) | 112.5 cm | ≥ 72.6 | PASS | Taiwan Design Code for Concrete Structures (2023) 13.2.8, 25.4 |
| y-direction bottom steel flexure (section at column face) | 1574.6 kN·m | ≥ 1200.0 | PASS | Taiwan Design Code for Concrete Structures (2023) Art. 13.4.6.2, Table 13.2.7.1 |
| y-direction bottom steel development (column face to bar end) | 112.5 cm | ≥ 72.6 | PASS | Taiwan Design Code for Concrete Structures (2023) 13.2.8, 25.4 |
| x-direction one-way shear (at d = 81.5 cm) | 570.8 kN | ≥ 281.8 | PASS | Taiwan Design Code for Concrete Structures (2023) Arts. 13.4.6.3(a), 13.4.6.5, Table 22.5.5.1(c) |
| x-direction shear limit at column face (piles within d of the face) | 7978.6 kN | ≥ 2000.0 | PASS | Taiwan Design Code for Concrete Structures (2023) Art. 13.4.6.5 commentary, Art. 9.9.2.1 |
| y-direction one-way shear (at d = 79.6 cm) | 567.0 kN | ≥ 345.5 | PASS | Taiwan Design Code for Concrete Structures (2023) Arts. 13.4.6.3(a), 13.4.6.5, Table 22.5.5.1(c) |
| y-direction shear limit at column face (piles within d of the face) | 7791.7 kN | ≥ 2000.0 | PASS | Taiwan Design Code for Concrete Structures (2023) Art. 13.4.6.5 commentary, Art. 9.9.2.1 |
| Two-way shear at column (d/2 from face) | 9.15 kgf/cm² | ≥ 7.46 | PASS | Taiwan Design Code for Concrete Structures (2023) Arts. 13.4.6.3(b), 13.4.6.5, Table 22.6.5.2, Art. 8.4.4.2 |
| Punching by a single pile (pile no. 1) | 1835.9 kN | ≥ 1000.0 | PASS | Taiwan Design Code for Concrete Structures (2023) Art. 13.2.7.2 commentary, Art. 22.6.4.1, Table 22.6.5.2 |
| Effective depth of bottom steel | 79.6 cm | ≥ 30.0 | PASS | Taiwan Design Code for Concrete Structures (2023) 13.4.6.1 |
3. Calculation Steps (calculation core output, SI units)
[HyGeoWorks online preview - not for PE sealing or submittal] Pile cap 3.00 × 3.00 × 1.00 m; effective depth d: x 81.5, y 79.6, average 80.6 cm; size effect λs = 0.688 Factored pile reactions: max 1000.0 kN, min 1000.0 kN (4 piles; rigid-cap distribution)
Checks (demand / capacity) (11 rows)
| Feature | Demand | Capacity or available | Unit | Ratio | Verdict | Reference / Applicability |
|---|---|---|---|---|---|---|
| x-direction bottom steel flexure (section at column face) | 1200.0 | 1613.2 | kN·m | 0.744 | PASS | 19-D19 (spacing 15.7 cm); As 54.4 ≥ max(required 40.3, minimum 54.0) cm² |
| x-direction bottom steel development (column face to bar end) | 72.6 | 112.5 | cm | 0.646 | PASS | available length 112.5 cm ≥ straight development length ℓd 72.6 cm |
| y-direction bottom steel flexure (section at column face) | 1200.0 | 1574.6 | kN·m | 0.762 | PASS | 19-D19 (spacing 15.7 cm); As 54.4 ≥ max(required 41.3, minimum 54.0) cm² |
| y-direction bottom steel development (column face to bar end) | 72.6 | 112.5 | cm | 0.646 | PASS | available length 112.5 cm ≥ straight development length ℓd 72.6 cm |
| x-direction one-way shear (at d = 81.5 cm) | 281.8 | 570.8 | kN | 0.494 | PASS | bw 300 cm, ρw 0.0022, λs 0.685 |
| x-direction shear limit at column face (piles within d of the face) | 2000.0 | 7978.6 | kN | 0.251 | PASS | The code commentary only refers to the CRSI Handbook and gives no expression; this check uses the deep-beam dimensional limit φ·2.65√fc'·bw·d as engineering judgement |
| y-direction one-way shear (at d = 79.6 cm) | 345.5 | 567.0 | kN | 0.609 | PASS | bw 300 cm, ρw 0.0023, λs 0.691 |
| y-direction shear limit at column face (piles within d of the face) | 2000.0 | 7791.7 | kN | 0.257 | PASS | The code commentary only refers to the CRSI Handbook and gives no expression; this check uses the deep-beam dimensional limit φ·2.65√fc'·bw·d as engineering judgement |
| Two-way shear at column (d/2 from face) | 7.46 | 9.15 | kgf/cm² | 0.814 | PASS | Vu 3313.7 kN, bo 562.4 cm, d 80.6 cm: direct shear stress 7.46 + moment transfer 0.00 kgf/cm²; vc eq. (a), λs 0.688 |
| Punching by a single pile (pile no. 1) | 1000.0 | 1835.9 | kN | 0.545 | PASS | equivalent square side 53.2 cm; critical section continuous on 2 sides, bo 253.8 cm; vc eq. (a) |
| Effective depth of bottom steel | 30.0 | 79.6 | cm | 0.377 | PASS | cap thickness 100 − pile embedment 10 − cover 7.5 − bar |
Bottom steel (2 rows)
| Direction | Mu (kN·m) | d (cm) | Required As (cm²) | Bars (spacing cm) | Provided As (cm²) | φMn (kN·m) | End anchorage |
|---|---|---|---|---|---|---|---|
| x-direction | 1200.0 | 81.5 | 54.0 | 19-D19 (@15.7) | 54.4 | 1613.2 | Straight |
| y-direction | 1200.0 | 79.6 | 54.0 | 19-D19 (@15.7) | 54.4 | 1574.6 | Straight |
Assumptions and Limits Stated by the Calculation Core
- Pile reactions are distributed for a rigid cap from the factored column loads; cap self-weight and overburden are excluded from cap moments and shears. The size effect factor λs of Art. 22.5.5.1.3 is applied (the exemption of Art. 13.2.6.2 does not cover pile caps): two-way shear λs = 0.688
- Not covered: strut-and-tie model (Art. 13.2.6.5), top and side reinforcement, pile head moments (pinned heads assumed), special seismic provisions
Frequently Asked Questions
Common questions about this calculator and its basis are answered below. Final submittals require review and seal by a licensed Professional Engineer.
Which design basis does this calculator apply?
Taiwan Design Code for Concrete Structures (2023; ACI 318-19 framework) Arts. 13.4.6, 13.2.7, 22.5, 22.6 (Table 22.6.5.2), 8.4.4.2, 25.4. Design follows the Taiwan concrete code named in the basis line (ACI 318-19 framework). This calculator covers the pile cap only; it does not compute a P–M interaction diagram for the piles. Bar sizes are D13–D32 and strengths are entered in kgf/cm².
What assumptions and limits does the calculation core state for this tool?
Pile reactions are distributed for a rigid cap from the factored column loads; cap self-weight and overburden are excluded from cap moments and shears. The size effect factor λs of Art. 22.5.5.1.3 is applied (the exemption of Art. 13.2.6.2 does not cover pile caps): two-way shear λs = 0.688. Not covered: strut-and-tie model (Art. 13.2.6.5), top and side reinforcement, pile head moments (pinned heads assumed), special seismic provisions.
Where is the calculation performed, and can the result be sealed or submitted?
The calculation runs in your browser, in the same WebAssembly calculation core this page loads. The result is an online preview: its first line reads "[HyGeoWorks online preview - not for PE sealing or submittal]".
Can I recalculate without a network connection?
Yes. "Download the offline workbench" on this page saves one HTML file that contains the workbench and the same calculation core; opened from disk it recalculates without a network connection.
From the Online Preview to the HydroStudio Desktop Edition: Reports Without the Trial Watermark
The free online preview is not for PE sealing or submittal and has no Word report, DXF drawing or verification code. Licensed users can sign in on the calculator and formally export a single-tool Word report (with a verification code) and DXF drawing. Several calculators can be combined in the Project List and exported online as a multi-chapter project report, and projects with terrain or GIS files can run in the heavy cloud computation. For interactive 2D models and large simulations, the HydroStudio desktop edition (Windows 10/11, 64-bit) opens the exported .toml project and, with a license, writes report.docx, a report.xlsx with live formulas and DXF drawings without the trial watermark. Sealing and submittal remain the responsibility of the licensed engineer.