HyGeoWorks
🔒 Previews run in your browser (WebAssembly) · Inputs are sent only when you formally export
Manning Uniform Flow · US Customary Inputs (SI Calculation Core)

Manning's Equation Open Channel Flow & Discharge Calculator (US Customary)

Uniform-flow calculator for trapezoidal, rectangular and circular sections at a given flow depth. US customary inputs (ft, ft/ft) are converted with exact factors to the SI calculation core, which applies the Manning equation V = (1/n)·R^(2/3)·S^(1/2) (Chow, 1959) and reports flow area, wetted perimeter, hydraulic radius, velocity, discharge, top width and Froude number.

Standards and references (context for this calculation; the basis the calculator applies is the one stated below):

Design basis for this page ▾
Manning Uniform Flow Equation V = (1/n)·R^(2/3)·S^(1/2) (SI / Chow, 1959)

Design basis as reported by the calculation core: Manning Uniform Flow Equation V = (1/n)·R^(2/3)·S^(1/2) (SI / Chow, 1959)

Recalculates in your browser as you edit inputs; Free sample Word report and DXF for this calculator; With a license: formal Word and DXF export, plus online project reports from the Project List.

Interactive US Customary Engineering Workstation
US customary inputs, shown as US (SI) in the results
Free Samples and Pricing
A public sample produced by the production service from this page's standard example and sealed with a verification code: open it in Word or AutoCAD and check it on the Verify page. Not for PE sealing or submittal.
Single-export pass: US$19 for one calculator, 3 formal exports in total within 24 hours of the first; full credit toward an upgrade within 30 days, full refund before the first export
Single-export passes (one calculator, 3 exports within 24 hours), 30-day passes, annual plans and perpetual licenses; printable quotes for purchase orders.
Formal export and the Project List are on the workbench toolbar above:
Licensed users can formally export this calculator's Word report (with a verification code and server time witness) and AutoCAD DXF drawing, or add several calculators to the free Project List and export a multi-chapter project report online, with nothing to install on a Mac. Projects with DEM terrain or GIS files can run in the heavy cloud computation or in the HydroStudio desktop edition.
The summary lists the basis, key results and check verdicts; its first line marks it as an online preview, not for PE sealing or submittal.
Download the Offline Workbench (Single HTML File, 39 Tools)
No install and no email required. It contains the same calculation core as this site; results are also a preview, not for sealed submittals.

Check Summary Preview (Software Format; Auto-Populated)

Manning's Equation Open Channel & Pipe Flow Calculator (cfs & fps): check summary (software format)
Calculation basis: Manning Uniform Flow Equation V = (1/n)·R^(2/3)·S^(1/2) (SI / Chow, 1959)
Check item Trial value Status
Flow Area A3.3445 m²Calculated value
Wetted Perimeter P5.9181 mCalculated value
Hydraulic Radius R0.5651 mCalculated value
Flow Velocity V3.222 m/sCalculated value

Summary of the online calculation (software format) for checking by the designer and an independent checker. Final submittals require review and seal by the licensed Professional Engineer in responsible charge.

Desktop edition: calculation reports and cross-module quantity reconciliation

1. Calculation reports: with a license, the desktop edition writes Word (.docx) and Excel (.xlsx) calculation reports and DXF drawings without the trial watermark, listing the inputs, the equations used and the results; in trial mode the step-by-step detail is hidden. For this calculator alone, licensed users can also sign in on the calculator above and formally export a single-tool Word report (with a verification code) and DXF drawing. The Pro plan (all modules) is US$990 per year; see Pricing for monthly, perpetual and team plans.
2. Cross-module reconciliation: desktop project runs carry the design peak flow into downstream channel, culvert and bridge hydraulics; terrain cut/fill into the earthwork balance, cost and carbon tables; structural concrete, formwork and rebar take-off into the cost and carbon tables; slope and excavation safety-factor thresholds into construction monitoring trigger levels.
3. Agency plan reviewers and university faculty can request a complimentary review or teaching license (link below).

Desktop pricing (Pro US$990/yr) Download the desktop trial Complimentary license for agency reviewers and faculty
Scope and responsibility: This page is a single-calculator trial run; cross-module quantity reconciliation is done in desktop project runs. Problems outside this calculator's scope (see the FAQ) need an appropriate analysis method. Final submittals require review and seal by a licensed Professional Engineer.

Governing Equations (US Customary Notation) & Basis Reported by the Calculation Core

The equations and limits the calculation core applies are listed below for independent checking.

Manning Velocity & Discharge (US Customary Form)
V = (1.486 / n) · R^(2/3) · S^(1/2) [fps], Q = A · V [cfs]
The calculation core evaluates the SI form V = (1/n)·R^(2/3)·S^(1/2) with the inputs converted at 1 ft = 0.3048 m; this equals the US form with Kn = 1 / 0.3048^(1/3) = 1.4859 (commonly rounded to 1.486). A = flow area (sq ft); P = wetted perimeter (ft); R = A/P = hydraulic radius (ft); S = bed slope (ft/ft); n = Manning roughness.
Froude Number (as reported by the calculation core)
Fr = V / √(g · A / T)
T = top water-surface width (ft); Fr < 1.0 subcritical, Fr > 1.0 supercritical. The core reports Fr and the flow regime; it does not compute boundary shear stress or freeboard.

Worked Example: Concrete Trapezoidal Channel (b = 6.0 ft, 2H:1V, y = 3.0 ft, S = 0.005)

The worked example below was computed by the calculation core when this page was built; entering the same inputs above reproduces it. Verification cases, tolerances and actual differences for the calculation core are listed on the Benchmarks page.

Compute the uniform-flow discharge, mean velocity and Froude number of a trapezoidal concrete channel with a 6.0-ft bottom width, 2H:1V side slopes, n = 0.015, a flow depth of 3.0 ft and a bed slope of 0.005 ft/ft.

Every number in this example was produced by the calculation core (WebAssembly) when this page was built. The calculation core works in SI units: the US customary inputs below are converted with exact NIST SP 811 factors before the calculation, and results are shown in US customary units with the core's SI value in parentheses. Check values, criteria and calculation steps are the core's own SI output. Basis reported by the core: Manning Uniform Flow Equation V = (1/n)·R^(2/3)·S^(1/2) (SI / Chow, 1959)

1. Input Parameters

Design ParameterUS Customary ValueUnit
Channel Cross-SectionTrapezoidal Channel—
Bottom Width b6ft
Side Slope z (zH:1V)2—
Manning's Roughness n0.015—
Longitudinal Bed Slope S0.005m/m
Flow Depth y3ft

2. Computed Results (calculation core output)

OutputResult
Flow Area A36 ft² (3.3445 m²)
Wetted Perimeter P19.42 ft (5.9181 m)
Hydraulic Radius R1.854 ft (0.5651 m)
Flow Velocity V10.57 ft/s (3.222 m/s)
Discharge Q380.6 cfs (10.7769 m³/s)
Top Width T18 ft (5.486 m)
Froude Number Fr1.318

3. Calculation Steps (calculation core output, SI units)

[HyGeoWorks online preview - not for PE sealing or submittal]
Section: Trapezoidal b = 1.829 m, side slope 1:2; n = 0.015, S = 0.005, depth y = 0.9144 m
A = (b + z·y)·y = (1.8288 + 2×0.9144)×0.9144 = 3.34451 m²
P = b + 2y·√(1 + z²) = 1.8288 + 2×0.9144×√(1 + 2²) = 5.91812 m
T = b + 2z·y = 5.48640 m
R = A/P = 0.56513 m
V = R^(2/3)·S^(1/2)/n = 0.56513^(2/3)×0.005^(1/2)/0.015 = 3.2223 m/s
Q = A·V = 10.77685 m³/s
Fr = V/√(g·A/T) = 3.2223/√(9.81×3.34451/5.48640) = 1.318 (Supercritical)
US customary equivalents (NIST SP 811 conversion of the SI values reported by the core above; the core summary itself is unchanged)
  Flow Area A = 36 ft²
  Wetted Perimeter P = 19.42 ft
  Hydraulic Radius R = 1.854 ft
  Flow Velocity V = 10.57 ft/s
  Discharge Q = 380.6 cfs
  Top Width T = 18 ft

Same Section with Other Manning n Values (computed by the calculation core when this page was built)

Inputs and outputs are listed with their units; conversion to and from SI is done by the calculation core.

Manning n (input)Flow Velocity VDischarge QFroude Number Fr
0.01312.2 ft/s (3.718 m/s)439.1 cfs (12.4348 m³/s)1.520
0.015 (worked example)10.57 ft/s (3.222 m/s)380.6 cfs (10.7769 m³/s)1.318
0.0246.607 ft/s (2.014 m/s)237.9 cfs (6.7355 m³/s)0.824
0.0354.531 ft/s (1.381 m/s)163.1 cfs (4.6187 m³/s)0.565

Frequently Asked Questions (Basis, Scope & Limits)

Common questions about this calculator and its basis are answered below. Final submittals require review and seal by a licensed Professional Engineer.

Does the calculator use the exact US customary Manning factor (1.4859) or the rounded 1.486?

The calculation core works in SI and evaluates V = (1/n)·R^(2/3)·S^(1/2). The US customary inputs are converted with exact factors (1 ft = 0.3048 m) before the calculation and the results are converted back, so the result equals the US form with Kn = 1 / 0.3048^(1/3) = 1.4859 rather than the rounded 1.486. The worked example lists each result in US customary units with the core's SI value in parentheses.

Why check the Froude number of a concrete channel?

Flow close to critical depth (Fr near 1.0) tends to form unstable standing waves, so designers usually keep the design flow clearly subcritical or supercritical. The calculation core reports Fr and the flow regime but applies no near-critical limit; compare Fr with the criterion of your governing drainage manual.

How does a part-full circular pipe behave near the crown?

For a circular pipe the Manning discharge peaks at a depth of about 0.94 D (y/D ≈ 0.938), because near the crown the wetted perimeter grows faster than the flow area. Above that depth the free-surface result is not a reliable capacity. The calculator evaluates the depth y you enter; the design depth ratio for storm drains is set by the governing agency.

Are my inputs uploaded to a server?

Not while you preview. Previews are calculated in your browser in WebAssembly and your inputs are not sent anywhere. Only when you click Formal export are that export's inputs sent over HTTPS to the license server, which builds the file in memory without writing it to disk or logging your values. The free online result is a preview marked as not for PE sealing or submittal; licensed users can formally export a single-tool Word report and DXF drawing, or combine several calculators in the Project List and export a whole-project report online; the HydroStudio desktop edition also produces whole-project reports.

USD Pricing · Checkout by Stripe · Printable USD Quotation

From the Online Preview to the HydroStudio Desktop Edition: Reports Without the Trial Watermark

The free online preview is not for PE sealing or submittal and has no Word report, DXF drawing or verification code. Licensed users can sign in on the calculator and formally export a single-tool Word report (with a verification code) and DXF drawing. Several calculators can be combined in the Project List and exported online as a multi-chapter project report, and projects with terrain or GIS files can run in the heavy cloud computation. For interactive 2D models and large simulations, the HydroStudio desktop edition (Windows 10/11, 64-bit) opens the exported .toml project and, with a license, writes report.docx, a report.xlsx with live formulas and DXF drawings without the trial watermark. Sealing and submittal remain the responsibility of the licensed engineer.

Monthly
Pro monthly
$119 / month
One discipline: $69 / month. Renews monthly until canceled; cancel any time before the next renewal and keep using it to the end of the paid month.
Buy monthly ($119/mo)
30 days
30-day pass
$79 / 30 days, one discipline
All modules: $135. One payment; it does not renew. The pass fee can be credited once toward an annual or perpetual license of the same discipline or a higher plan bought within 30 days after the pass ends, with the same email and in the same currency.
Buy a 30-day pass (from $79)
Quotation
Printable USD quotation
For any plan, including Firm (from 3 seats) and Enterprise (from 10 seats), which are sold only to businesses and other organizations, not to individual buyers: print the quotation or save it as a PDF for your purchasing process.
Request a printable USD quotation

Compare all plans, including 90-day passes and perpetual licenses

Checkout is processed by Stripe; a tax ID can be entered at checkout, and for one-time payments Stripe issues an invoice showing the buyer's name and tax ID. Procurement follows your organization's own rules.

Explore All 31 Tools (20 US Customary + 11 Reference: Basis Stated on Each Page)

Need to edit terrain, 2D flood models and design alternatives interactively on your computer, or see 3D views drawn from your project data? Use the HydroStudio desktop edition:
Download the Desktop Trial
No credit card or phone number is needed to download. Without a license it runs as a trial: local calculation and 3D viewing work, exported reports and drawings carry a trial watermark (not for submittal), and some built-in data libraries are limited. Plans and prices are on the Pricing page.