Stormwater Detention Orifice & Rectangular Weir Sizing Calculator
Outlet sizing for detention basins and vaults: the calculation core solves the orifice equation Q = N·Cd·(πD²/4)·√(2g(H − D/2)) or the rectangular weir equation Q = Cw·L·H^1.5 for the size that passes the allowable release, rounds the size down to your increment and reports the actual outflow of the adopted size.
Standards and references (context for this calculation; the basis the calculator applies is the one stated below):
Design basis as reported by the calculation core: Orifice Q = Cd·A·√(2gH) & Sharp/Broad-Crested Rectangular Weir Q = Cw·L·H^1.5
Recalculates in your browser as you edit inputs; Free sample Word report and DXF for this calculator; With a license: formal Word and DXF export, plus online project reports from the Project List; 3D schematic: fixed example, not drawn from your inputs.
Check Summary Preview (Software Format; Auto-Populated)
| Check item | Trial value | Status |
|---|---|---|
| Required Orifice Diameter D_req | 0.3993 m | Calculated value |
| Adopted Orifice Diameter D | 0.381 m | Calculated value |
| Actual Outflow Q | 0.3878 m³/s | Calculated value |
Summary of the online calculation (software format) for checking by the designer and an independent checker. Final submittals require review and seal by the licensed Professional Engineer in responsible charge.
Desktop edition: calculation reports and cross-module quantity reconciliation
1. Calculation reports: with a license, the desktop edition writes Word (.docx) and Excel (.xlsx) calculation reports and DXF drawings without the trial watermark, listing the inputs, the equations used and the results; in trial mode the step-by-step detail is hidden. For this calculator alone, licensed users can also sign in on the calculator above and formally export a single-tool Word report (with a verification code) and DXF drawing. The Pro plan (all modules) is US$990 per year; see Pricing for monthly, perpetual and team plans.
2. Cross-module reconciliation: desktop project runs carry the design peak flow into downstream channel, culvert and bridge hydraulics; terrain cut/fill into the earthwork balance, cost and carbon tables; structural concrete, formwork and rebar take-off into the cost and carbon tables; slope and excavation safety-factor thresholds into construction monitoring trigger levels.
3. Agency plan reviewers and university faculty can request a complimentary review or teaching license (link below).
Governing Equations (US Customary Notation) & Basis Reported by the Calculation Core
The equations and limits the calculation core applies are listed below for independent checking.
Worked Example: Single Circular Orifice for Q_allow = 15.0 cfs at 6.0 ft Head
The worked example below was computed by the calculation core when this page was built; entering the same inputs above reproduces it. Verification cases, tolerances and actual differences for the calculation core are listed on the Benchmarks page.
Size a single sharp-edged circular orifice (C_d = 0.60) with 6.0 ft of head above the orifice invert so that the outflow does not exceed 15.0 cfs, rounded down to a 0.25-ft increment.
Every number in this example was produced by the calculation core (WebAssembly) when this page was built. The calculation core works in SI units: the US customary inputs below are converted with exact NIST SP 811 factors before the calculation, and results are shown in US customary units with the core's SI value in parentheses. Check values, criteria and calculation steps are the core's own SI output. Basis reported by the core: Orifice Q = Cd·A·√(2gH) & Sharp/Broad-Crested Rectangular Weir Q = Cw·L·H^1.5
1. Input Parameters
| Design Parameter | US Customary Value | Unit |
|---|---|---|
| Outlet Control Type | Circular Orifice | — |
| Max Allowable Release Q_allow | 15 | cfs |
| Design Head H (above Invert/Crest) | 6 | ft |
| Orifice Coefficient C_d | 0.6 | — |
| Number of Orifices N | 1 | — |
| Fabrication Increment (Round Down) | 0.25 | ft |
2. Computed Results (calculation core output)
| Output | Result |
|---|---|
| Required Orifice Diameter D_req | 1.31 ft (0.3993 m) |
| Adopted Orifice Diameter D | 1.25 ft (0.381 m) |
| Actual Outflow Q | 13.7 cfs (0.3878 m³/s) |
3. Calculation Steps (calculation core output, SI units)
[HyGeoWorks online preview - not for PE sealing or submittal] Submerged / full orifice flow: Q = N·Cd·(πD²/4)·√(2g(H − D/2)), N = 1, Cd = 0.6, H = 1.8288 m → D = 0.3993 m (check Q = 0.4248 m³/s) Adopt D = 0.381 m (to the nearest 0.0762 m, rounded down) -> Q = 0.3878 m³/s ≤ 0.424753
US customary equivalents (NIST SP 811 conversion of the SI values reported by the core above; the core summary itself is unchanged) Required Orifice Diameter D_req = 1.31 ft Adopted Orifice Diameter D = 1.25 ft Actual Outflow Q = 13.7 cfs
Frequently Asked Questions (Basis, Scope & Limits)
Common questions about this calculator and its basis are answered below. Final submittals require review and seal by a licensed Professional Engineer.
Why does this tool round the orifice size down while pipe sizing rounds up?
A conveyance pipe is rounded up so that its capacity is at least the design flow. A detention outlet limits the release, so the size is rounded down: the adopted size passes an outflow no greater than the allowable release. The worked example lists the actual outflow of the adopted orifice.
Why use (H − D/2) instead of H in the orifice equation?
H is entered relative to the orifice invert (bottom edge), which is how stage-storage-discharge tables are usually set up. Subtracting D/2 refers the head to the centroid of the circular opening.
Is there a minimum orifice size?
The calculator applies none. Small orifices clog easily; minimum sizes and trash-rack requirements are set by local stormwater manuals, so check the adopted diameter against your agency's rule.
Can the HydroStudio desktop edition route a detention pond through the outlet?
Yes. The HydroStudio desktop edition includes level-pool routing of detention storage through orifice and weir outlets, with a time-varying downstream water level (submergence) and flap gates. Verification cases are listed on the Benchmarks page.
From the Online Preview to the HydroStudio Desktop Edition: Reports Without the Trial Watermark
The free online preview is not for PE sealing or submittal and has no Word report, DXF drawing or verification code. Licensed users can sign in on the calculator and formally export a single-tool Word report (with a verification code) and DXF drawing. Several calculators can be combined in the Project List and exported online as a multi-chapter project report, and projects with terrain or GIS files can run in the heavy cloud computation. For interactive 2D models and large simulations, the HydroStudio desktop edition (Windows 10/11, 64-bit) opens the exported .toml project and, with a license, writes report.docx, a report.xlsx with live formulas and DXF drawings without the trial watermark. Sealing and submittal remain the responsibility of the licensed engineer.
Compare all plans, including 90-day passes and perpetual licenses