HyGeoWorks
🔒 Previews run in your browser (WebAssembly) · Inputs are sent only when you formally export
Pipe Diameter & Channel Width Sizing · Rounded Up to Your Size Increment

Circular Pipe Diameter & Channel Bottom Width Sizing Calculator (Manning)

Inverse Manning sizing: the calculation core solves by bisection for the exact pipe diameter (at the target y/D) or channel bottom width (at the target depth) that carries the design discharge, rounds it up to the size increment you enter and reports the normal depth and velocity of the adopted size. The default depth ratio and freeboard note follow the Taiwan Soil and Water Conservation Technical Regulations Arts. 87 and 86. No minimum (self-cleansing) velocity check is applied.

Standards and references (context for this calculation; the basis the calculator applies is the one stated below):

Design basis for this page ▾
Manning Uniform Flow Bisection SizingDefault pipe depth ratio and freeboard note: Taiwan Soil and Water Conservation Technical Regulations Arts. 87 and 86

Design basis as reported by the calculation core: Manning Uniform Flow Bisection Sizing; default pipe depth ratio and freeboard note per Taiwan Soil and Water Conservation Technical Regulations Arts. 87 and 86

Recalculates in your browser as you edit inputs; Free sample Word report and DXF for this calculator; With a license: formal Word and DXF export, plus online project reports from the Project List.

Interactive US Customary Engineering Workstation
US customary inputs, shown as US (SI) in the results
Free Samples and Pricing
A public sample produced by the production service from this page's standard example and sealed with a verification code: open it in Word or AutoCAD and check it on the Verify page. Not for PE sealing or submittal.
Single-export pass: US$19 for one calculator, 3 formal exports in total within 24 hours of the first; full credit toward an upgrade within 30 days, full refund before the first export
Single-export passes (one calculator, 3 exports within 24 hours), 30-day passes, annual plans and perpetual licenses; printable quotes for purchase orders.
Formal export and the Project List are on the workbench toolbar above:
Licensed users can formally export this calculator's Word report (with a verification code and server time witness) and AutoCAD DXF drawing, or add several calculators to the free Project List and export a multi-chapter project report online, with nothing to install on a Mac. Projects with DEM terrain or GIS files can run in the heavy cloud computation or in the HydroStudio desktop edition.
The summary lists the basis, key results and check verdicts; its first line marks it as an online preview, not for PE sealing or submittal.
Download the Offline Workbench (Single HTML File, 39 Tools)
No install and no email required. It contains the same calculation core as this site; results are also a preview, not for sealed submittals.

Check Summary Preview (Software Format; Auto-Populated)

Storm Drain Pipe Diameter & Open Channel Width Sizing Calculator (Manning): check summary (software format)
Calculation basis: Manning Uniform Flow Bisection Sizing; default pipe depth ratio and freeboard note per Taiwan Soil and Water Conservation Technical Regulations Arts. 87 and 86
Check item Trial value Status
Exact Required Diameter D_req0.7461 mCalculated value
Adopted Pipe Diameter D0.762 mCalculated value
Normal Depth yn0.5456 mCalculated value
Flow Velocity V2.026 m/sCalculated value

Summary of the online calculation (software format) for checking by the designer and an independent checker. Final submittals require review and seal by the licensed Professional Engineer in responsible charge.

Desktop edition: calculation reports and cross-module quantity reconciliation

1. Calculation reports: with a license, the desktop edition writes Word (.docx) and Excel (.xlsx) calculation reports and DXF drawings without the trial watermark, listing the inputs, the equations used and the results; in trial mode the step-by-step detail is hidden. For this calculator alone, licensed users can also sign in on the calculator above and formally export a single-tool Word report (with a verification code) and DXF drawing. The Pro plan (all modules) is US$990 per year; see Pricing for monthly, perpetual and team plans.
2. Cross-module reconciliation: desktop project runs carry the design peak flow into downstream channel, culvert and bridge hydraulics; terrain cut/fill into the earthwork balance, cost and carbon tables; structural concrete, formwork and rebar take-off into the cost and carbon tables; slope and excavation safety-factor thresholds into construction monitoring trigger levels.
3. Agency plan reviewers and university faculty can request a complimentary review or teaching license (link below).

Desktop pricing (Pro US$990/yr) Download the desktop trial Complimentary license for agency reviewers and faculty
Scope and responsibility: This page is a single-calculator trial run; cross-module quantity reconciliation is done in desktop project runs. Problems outside this calculator's scope (see the FAQ) need an appropriate analysis method. Final submittals require review and seal by a licensed Professional Engineer.

Governing Equations (US Customary Notation) & Basis Reported by the Calculation Core

The equations and limits the calculation core applies are listed below for independent checking.

Required Diameter at the Target Depth Ratio (solved by bisection)
Q = (1.486 / n) · [k_A(y/D) · D²] · [k_R(y/D) · D]^(2/3) · S^(1/2) => D_req ∝ [Q · n / (1.486 · S^(1/2))]^(3/8)
At y/D = 0.75: k_A = 0.63185, k_R = 0.30169. The core solves Q(D) = Q by bisection and adopts D = ceil(D_req / ΔD) · ΔD.
Normal Depth and Velocity of the Adopted Size
Q(y_n; D_adopted) = Q, V = Q / A(y_n)
The core reports y_n, y_n/D and V for the adopted size. It applies no minimum self-cleansing velocity; compare V with the minimum velocity of your agency.

Worked Example: Circular Storm Drain for Q = 25 cfs (S = 0.005, y/D = 0.75)

The worked example below was computed by the calculation core when this page was built; entering the same inputs above reproduces it. Verification cases, tolerances and actual differences for the calculation core are listed on the Benchmarks page.

Find the circular pipe diameter that carries Q = 25 cfs at S = 0.005 ft/ft and n = 0.013 at a depth ratio of 0.75, rounded up to a 0.5-ft (6-in.) increment, and report the normal depth and velocity of the adopted size.

Every number in this example was produced by the calculation core (WebAssembly) when this page was built. The calculation core works in SI units: the US customary inputs below are converted with exact NIST SP 811 factors before the calculation, and results are shown in US customary units with the core's SI value in parentheses. Check values, criteria and calculation steps are the core's own SI output. Basis reported by the core: Manning Uniform Flow Bisection Sizing; default pipe depth ratio and freeboard note per Taiwan Soil and Water Conservation Technical Regulations Arts. 87 and 86

1. Input Parameters

Design ParameterUS Customary ValueUnit
Conduit / Channel TypeCircular Pipe—
Manning's Roughness n0.013—
Invert Slope S0.005m/m
Design Peak Flow Q25cfs
Target Depth Ratio y/D0.75—
Size Rounding Increment0.5ft

2. Computed Results (calculation core output)

OutputResult
Exact Required Diameter D_req2.448 ft (0.7461 m)
Adopted Pipe Diameter D2.5 ft (0.762 m)
Normal Depth yn1.79 ft (0.5456 m)
Flow Velocity V6.646 ft/s (2.026 m/s)

3. Calculation Steps (calculation core output, SI units)

[HyGeoWorks online preview - not for PE sealing or submittal]
Given: Q = 0.707921 m³/s, n = 0.013, S = 0.005, y = 0.75D
Solve D for Q(D, y = 0.75D) = A·R^(2/3)·S^(1/2)/n = 0.707921 → D = 0.7461 m
Adopt D = 0.762 m (to the nearest 0.1524 m, rounded up) -> normal depth yn = 0.5456 m, yn/D = 0.716, V = 2.026 m/s
US customary equivalents (NIST SP 811 conversion of the SI values reported by the core above; the core summary itself is unchanged)
  Exact Required Diameter D_req = 2.448 ft
  Adopted Pipe Diameter D = 2.5 ft
  Normal Depth yn = 1.79 ft
  Flow Velocity V = 6.646 ft/s

Assumptions and Limits Stated by the Calculation Core

Pipe Sizes Selected by the Calculation Core for Other Design Flows (n = 0.013, S = 0.005, y/D = 0.75, 0.5-ft increment)

Inputs and outputs are listed with their units; conversion to and from SI is done by the calculation core.

Design Flow Q (input)Exact Required DiameterAdopted DiameterNormal Depth y_nVelocity V
10 cfs1.736 ft (0.5291 m)2 ft (0.610 m)1.146 ft (0.3492 m)5.373 ft/s (1.638 m/s)
25 cfs (worked example)2.448 ft (0.7461 m)2.5 ft (0.762 m)1.79 ft (0.5456 m)6.646 ft/s (2.026 m/s)
50 cfs3.174 ft (0.9676 m)3.5 ft (1.067 m)2.164 ft (0.6595 m)8.007 ft/s (2.441 m/s)
100 cfs4.117 ft (1.2548 m)4.5 ft (1.372 m)2.825 ft (0.8611 m)9.513 ft/s (2.900 m/s)

Frequently Asked Questions (Basis, Scope & Limits)

Common questions about this calculator and its basis are answered below. Final submittals require review and seal by a licensed Professional Engineer.

Why size a gravity storm drain below full depth?

A depth ratio below 1.0 keeps an air space above the water surface and leaves some reserve for debris and for flows above the design flow. The worked example uses y/D = 0.75; the default depth ratio of the calculation core follows the Taiwan Soil and Water Conservation Technical Regulations Art. 87, so enter the ratio your agency requires.

Which pipe sizes does the calculator choose?

It rounds the exact diameter up to a multiple of the increment you enter (0.5 ft = 6 in. in the worked example). It holds no manufacturer's size list; the calculation core notes that the diameter should be selected from the pipe manufacturer's catalog, so confirm that the adopted size is available from your pipe supplier.

Does the calculator check a minimum self-cleansing velocity?

No. The core reports the velocity of the adopted size but applies no minimum-velocity check; compare it with the minimum velocity your agency specifies.

Can this tool also size trapezoidal swales or concrete ditches?

Yes. Switch 'Conduit / Channel Type' to Trapezoidal or Rectangular, enter the target flow depth y (ft) and side slope z, and the calculation core returns the required bottom width rounded up to your increment.

USD Pricing · Checkout by Stripe · Printable USD Quotation

From the Online Preview to the HydroStudio Desktop Edition: Reports Without the Trial Watermark

The free online preview is not for PE sealing or submittal and has no Word report, DXF drawing or verification code. Licensed users can sign in on the calculator and formally export a single-tool Word report (with a verification code) and DXF drawing. Several calculators can be combined in the Project List and exported online as a multi-chapter project report, and projects with terrain or GIS files can run in the heavy cloud computation. For interactive 2D models and large simulations, the HydroStudio desktop edition (Windows 10/11, 64-bit) opens the exported .toml project and, with a license, writes report.docx, a report.xlsx with live formulas and DXF drawings without the trial watermark. Sealing and submittal remain the responsibility of the licensed engineer.

Monthly
Pro monthly
$119 / month
One discipline: $69 / month. Renews monthly until canceled; cancel any time before the next renewal and keep using it to the end of the paid month.
Buy monthly ($119/mo)
30 days
30-day pass
$79 / 30 days, one discipline
All modules: $135. One payment; it does not renew. The pass fee can be credited once toward an annual or perpetual license of the same discipline or a higher plan bought within 30 days after the pass ends, with the same email and in the same currency.
Buy a 30-day pass (from $79)
Quotation
Printable USD quotation
For any plan, including Firm (from 3 seats) and Enterprise (from 10 seats), which are sold only to businesses and other organizations, not to individual buyers: print the quotation or save it as a PDF for your purchasing process.
Request a printable USD quotation

Compare all plans, including 90-day passes and perpetual licenses

Checkout is processed by Stripe; a tax ID can be entered at checkout, and for one-time payments Stripe issues an invoice showing the buyer's name and tax ID. Procurement follows your organization's own rules.

Explore All 31 Tools (20 US Customary + 11 Reference: Basis Stated on Each Page)

Need to edit terrain, 2D flood models and design alternatives interactively on your computer, or see 3D views drawn from your project data? Use the HydroStudio desktop edition:
Download the Desktop Trial
No credit card or phone number is needed to download. Without a license it runs as a trial: local calculation and 3D viewing work, exported reports and drawings carry a trial watermark (not for submittal), and some built-in data libraries are limited. Plans and prices are on the Pricing page.