Circular Pipe Diameter & Channel Bottom Width Sizing Calculator (Manning)
Inverse Manning sizing: the calculation core solves by bisection for the exact pipe diameter (at the target y/D) or channel bottom width (at the target depth) that carries the design discharge, rounds it up to the size increment you enter and reports the normal depth and velocity of the adopted size. The default depth ratio and freeboard note follow the Taiwan Soil and Water Conservation Technical Regulations Arts. 87 and 86. No minimum (self-cleansing) velocity check is applied.
Standards and references (context for this calculation; the basis the calculator applies is the one stated below):
Design basis as reported by the calculation core: Manning Uniform Flow Bisection Sizing; default pipe depth ratio and freeboard note per Taiwan Soil and Water Conservation Technical Regulations Arts. 87 and 86
Recalculates in your browser as you edit inputs; Free sample Word report and DXF for this calculator; With a license: formal Word and DXF export, plus online project reports from the Project List.
Check Summary Preview (Software Format; Auto-Populated)
| Check item | Trial value | Status |
|---|---|---|
| Exact Required Diameter D_req | 0.7461 m | Calculated value |
| Adopted Pipe Diameter D | 0.762 m | Calculated value |
| Normal Depth yn | 0.5456 m | Calculated value |
| Flow Velocity V | 2.026 m/s | Calculated value |
Summary of the online calculation (software format) for checking by the designer and an independent checker. Final submittals require review and seal by the licensed Professional Engineer in responsible charge.
Desktop edition: calculation reports and cross-module quantity reconciliation
1. Calculation reports: with a license, the desktop edition writes Word (.docx) and Excel (.xlsx) calculation reports and DXF drawings without the trial watermark, listing the inputs, the equations used and the results; in trial mode the step-by-step detail is hidden. For this calculator alone, licensed users can also sign in on the calculator above and formally export a single-tool Word report (with a verification code) and DXF drawing. The Pro plan (all modules) is US$990 per year; see Pricing for monthly, perpetual and team plans.
2. Cross-module reconciliation: desktop project runs carry the design peak flow into downstream channel, culvert and bridge hydraulics; terrain cut/fill into the earthwork balance, cost and carbon tables; structural concrete, formwork and rebar take-off into the cost and carbon tables; slope and excavation safety-factor thresholds into construction monitoring trigger levels.
3. Agency plan reviewers and university faculty can request a complimentary review or teaching license (link below).
Governing Equations (US Customary Notation) & Basis Reported by the Calculation Core
The equations and limits the calculation core applies are listed below for independent checking.
Worked Example: Circular Storm Drain for Q = 25 cfs (S = 0.005, y/D = 0.75)
The worked example below was computed by the calculation core when this page was built; entering the same inputs above reproduces it. Verification cases, tolerances and actual differences for the calculation core are listed on the Benchmarks page.
Find the circular pipe diameter that carries Q = 25 cfs at S = 0.005 ft/ft and n = 0.013 at a depth ratio of 0.75, rounded up to a 0.5-ft (6-in.) increment, and report the normal depth and velocity of the adopted size.
Every number in this example was produced by the calculation core (WebAssembly) when this page was built. The calculation core works in SI units: the US customary inputs below are converted with exact NIST SP 811 factors before the calculation, and results are shown in US customary units with the core's SI value in parentheses. Check values, criteria and calculation steps are the core's own SI output. Basis reported by the core: Manning Uniform Flow Bisection Sizing; default pipe depth ratio and freeboard note per Taiwan Soil and Water Conservation Technical Regulations Arts. 87 and 86
1. Input Parameters
| Design Parameter | US Customary Value | Unit |
|---|---|---|
| Conduit / Channel Type | Circular Pipe | — |
| Manning's Roughness n | 0.013 | — |
| Invert Slope S | 0.005 | m/m |
| Design Peak Flow Q | 25 | cfs |
| Target Depth Ratio y/D | 0.75 | — |
| Size Rounding Increment | 0.5 | ft |
2. Computed Results (calculation core output)
| Output | Result |
|---|---|
| Exact Required Diameter D_req | 2.448 ft (0.7461 m) |
| Adopted Pipe Diameter D | 2.5 ft (0.762 m) |
| Normal Depth yn | 1.79 ft (0.5456 m) |
| Flow Velocity V | 6.646 ft/s (2.026 m/s) |
3. Calculation Steps (calculation core output, SI units)
[HyGeoWorks online preview - not for PE sealing or submittal] Given: Q = 0.707921 m³/s, n = 0.013, S = 0.005, y = 0.75D Solve D for Q(D, y = 0.75D) = A·R^(2/3)·S^(1/2)/n = 0.707921 → D = 0.7461 m Adopt D = 0.762 m (to the nearest 0.1524 m, rounded up) -> normal depth yn = 0.5456 m, yn/D = 0.716, V = 2.026 m/s
US customary equivalents (NIST SP 811 conversion of the SI values reported by the core above; the core summary itself is unchanged) Exact Required Diameter D_req = 2.448 ft Adopted Pipe Diameter D = 2.5 ft Normal Depth yn = 1.79 ft Flow Velocity V = 6.646 ft/s
Assumptions and Limits Stated by the Calculation Core
- Select the pipe diameter from the pipe manufacturer's catalogue (e.g. CNS 483 reinforced concrete pipe)
Pipe Sizes Selected by the Calculation Core for Other Design Flows (n = 0.013, S = 0.005, y/D = 0.75, 0.5-ft increment)
Inputs and outputs are listed with their units; conversion to and from SI is done by the calculation core.
| Design Flow Q (input) | Exact Required Diameter | Adopted Diameter | Normal Depth y_n | Velocity V |
|---|---|---|---|---|
| 10 cfs | 1.736 ft (0.5291 m) | 2 ft (0.610 m) | 1.146 ft (0.3492 m) | 5.373 ft/s (1.638 m/s) |
| 25 cfs (worked example) | 2.448 ft (0.7461 m) | 2.5 ft (0.762 m) | 1.79 ft (0.5456 m) | 6.646 ft/s (2.026 m/s) |
| 50 cfs | 3.174 ft (0.9676 m) | 3.5 ft (1.067 m) | 2.164 ft (0.6595 m) | 8.007 ft/s (2.441 m/s) |
| 100 cfs | 4.117 ft (1.2548 m) | 4.5 ft (1.372 m) | 2.825 ft (0.8611 m) | 9.513 ft/s (2.900 m/s) |
Frequently Asked Questions (Basis, Scope & Limits)
Common questions about this calculator and its basis are answered below. Final submittals require review and seal by a licensed Professional Engineer.
Why size a gravity storm drain below full depth?
A depth ratio below 1.0 keeps an air space above the water surface and leaves some reserve for debris and for flows above the design flow. The worked example uses y/D = 0.75; the default depth ratio of the calculation core follows the Taiwan Soil and Water Conservation Technical Regulations Art. 87, so enter the ratio your agency requires.
Which pipe sizes does the calculator choose?
It rounds the exact diameter up to a multiple of the increment you enter (0.5 ft = 6 in. in the worked example). It holds no manufacturer's size list; the calculation core notes that the diameter should be selected from the pipe manufacturer's catalog, so confirm that the adopted size is available from your pipe supplier.
Does the calculator check a minimum self-cleansing velocity?
No. The core reports the velocity of the adopted size but applies no minimum-velocity check; compare it with the minimum velocity your agency specifies.
Can this tool also size trapezoidal swales or concrete ditches?
Yes. Switch 'Conduit / Channel Type' to Trapezoidal or Rectangular, enter the target flow depth y (ft) and side slope z, and the calculation core returns the required bottom width rounded up to your increment.
From the Online Preview to the HydroStudio Desktop Edition: Reports Without the Trial Watermark
The free online preview is not for PE sealing or submittal and has no Word report, DXF drawing or verification code. Licensed users can sign in on the calculator and formally export a single-tool Word report (with a verification code) and DXF drawing. Several calculators can be combined in the Project List and exported online as a multi-chapter project report, and projects with terrain or GIS files can run in the heavy cloud computation. For interactive 2D models and large simulations, the HydroStudio desktop edition (Windows 10/11, 64-bit) opens the exported .toml project and, with a license, writes report.docx, a report.xlsx with live formulas and DXF drawings without the trial watermark. Sealing and submittal remain the responsibility of the licensed engineer.
Compare all plans, including 90-day passes and perpetual licenses