Check Summary Preview (Software Format; Auto-Populated)
| Check item | Trial value | Status |
|---|---|---|
| Spillway Overflow Depth h | 1.754 m ≤ 3.0 m | OK |
Summary of the online calculation (software format) for checking by the designer and an independent checker. Final sign-off remains the responsibility of the chartered or registered engineer.
Desktop edition: calculation reports and cross-module quantity reconciliation
1. Calculation reports: with a licence, the desktop edition writes Word (.docx) and Excel (.xlsx) calculation reports and DXF drawings without the trial watermark, listing the inputs, the equations used and the results; in trial mode the step-by-step detail is hidden. For this calculator alone, licensed users can also sign in on the calculator above and formally export a single-tool Word report (with a verification code) and DXF drawing. The Pro plan (all modules) is US$990 per year; see Pricing for monthly, perpetual and team plans.
2. Cross-module reconciliation: desktop project runs carry the design peak flow into downstream channel, culvert and bridge hydraulics; terrain cut/fill into the earthwork balance, cost and carbon tables; structural concrete, formwork and rebar take-off into the cost and carbon tables; slope and excavation safety-factor thresholds into construction monitoring trigger levels.
3. Independent checking engineers, authority reviewers and academics can request a complimentary review or teaching licence (link below).
1. Governing Equations & SI Nomenclature
The equations the calculation core applies are summarised below for independent checking.
The equations below summarise the method that the calculation core applies on this page. The design basis it reports is: Taiwan Soil and Water Conservation Handbook (2017) §2.1 Eqs. 2.1.2–2.1.4, 2.1.46–2.1.50 (trapezoidal spillway, freeboard, apron); Taiwan Soil and Water Conservation Technical Regulations Art. 65. The worked example further down lists the core's own calculation steps for the standard example.
2. Worked Standard Example (Computed by the Calculation Core)
The worked example below was computed by the calculation core when this page was built; entering the same inputs above reproduces it.
Design Scenario — 9.5 m Gravity Check Dam on a 10% Torrent Bed (Qp = 40 m³/s): Determine the bulked design discharge (α = 0.10), overflow depth, spillway freeboard and downstream apron length for a check dam with a total height of 9.5 m and an effective height of 8.0 m on a torrent bed of slope 0.10, with a trapezoidal spillway 10.0 m wide at the bottom and side slopes of 1:0.5 on a gravel foundation.
The inputs below were passed to the calculation core (WebAssembly) when this page was built; every step, result and check shown here is the core's own output. Basis reported by the core: Taiwan Soil and Water Conservation Handbook (2017) §2.1 Eqs. 2.1.2–2.1.4, 2.1.46–2.1.50 (trapezoidal spillway, freeboard, apron); Taiwan Soil and Water Conservation Technical Regulations Art. 65
Inputs Passed to the Calculation Core
| Parameter | Value | Unit |
|---|---|---|
| Clear-Water Peak Flow Qp | 40 | m³/s |
| Debris Bulking Factor α | 0.1 | — |
| Spillway Bottom Width bo | 10 | m |
| Spillway Side Slope 1:Z | 0.5 | — |
| Original Torrent Bed Slope So | 0.1 | m/m |
| Effective Dam Height He | 8 | m |
| Total Dam Height H | 9.5 | m |
| Sound Rock Foundation | No | — |
| Dam Body Stability Check | Not calculated | — |
Calculation Steps (calculation core output)
[HyGeoWorks online preview - not for PE sealing or submittal]
- Design debris-laden peak discharge Qd = (1 + 0.1) × 40 = 44.000 m³/s
- Trapezoidal spillway depth: Qd = 0.354·bu·(2 + 3χ)·h^1.5 → overflow depth h = 1.754 m, top width bu = 11.754 m, freeboard hf = 0.702 m
- Downstream apron length L = 19.51 m, end sill height = 1.60 m, sub-dam spacing = 14.63–19.51 m
Computed Results (calculation core output)
| Output Parameter | Calculated Value | SI Unit |
|---|---|---|
| Design Discharge Qd | 44.000 | m³/s |
| Spillway Overflow Depth h | 1.754 | m |
| Spillway Freeboard hf | 0.702 | m |
| Downstream Apron Length L | 19.51 | m |
Verification Checks (calculation core output)
| Verification Check | Computed Value | Criterion | Verdict | Basis |
|---|---|---|---|---|
| Spillway Overflow Depth h | 1.754 m | ≤ 3.0 m | OK | Taiwan Soil and Water Conservation Handbook (2017) §2.1 (p. 321) |
3. Regional Design Options in This Edition: UK, EU, Singapore, Malaysia, Hong Kong & Australia
Symbols and units are SI unless stated otherwise.
- This calculator: the design basis is the one reported by the calculation core: Taiwan Soil and Water Conservation Handbook (2017) §2.1 Eqs. 2.1.2–2.1.4, 2.1.46–2.1.50 (trapezoidal spillway, freeboard, apron); Taiwan Soil and Water Conservation Technical Regulations Art. 65. The options listed below belong to the calculators named in each item.
- United Kingdom, Ireland & European Union: The retaining wall and slope stability calculators default to EN 1997-1:2004 Design Approach 1 (Combination 1 & Combination 2); the UK National Annex and 2nd-Gen EN 1997-1:2024 / EN 1997-3:2025 (MFA, and RFA for retaining walls) are selectable there, as are DA2 for retaining walls and DA3 for slopes. The retaining wall calculator lets γG, γQ and γφ' be overridden for a National Annex and designs metric H-bars (H10–H32) when concrete and steel strengths are entered.
- Singapore & Malaysia: The retaining wall calculator offers SS EN 1997-1:2010 with the Singapore National Annex, and the detention calculator offers a DID Malaysia MSMA 2nd Edition (2012) Equation 2.2 IDF rainfall mode besides directly entered design intensities.
- Hong Kong SAR: HyGeoWorks does not claim Hong Kong Buildings Department pre-accepted program status; the retaining wall calculator's HK GEO Geoguide 1 option shows the calculation core's steps and checks so that the result can be checked independently. With that option the calculation core applies the Geoguide 1 Table 6 and Table 7 partial factors at ULS and the §9.2.4 middle-third eccentricity check at SLS.
- Australia & New Zealand: No ARR 2019 IFD data is built in; design rainfall intensities for any AEP can be entered directly in the detention calculator. The HydroStudio desktop edition supports GDA2020 / MGA2020 zones 46–59 as well as WGS 84 / UTM zones.
4. Frequently Asked Questions
Common questions about this calculator are answered below. Final sign-off remains the responsibility of the chartered or registered engineer.
What does this calculator cover?
The hydraulic proportioning of the spillway and downstream protection: the bulked design discharge, the overflow depth (checked against the handbook limit), the spillway freeboard, the apron length, the end-sill height and the sub-dam spacing, per Taiwan Soil and Water Conservation Handbook (2017) §2.1, as reported by the calculation core. Dam-body stability is not included.
Why is the clear-water peak multiplied by (1 + α)?
Floods in steep torrents carry sediment and woody debris, so the flow passing the spillway is larger than the clear-water runoff. The handbook design discharge is Qd = (1 + α)·Qp, where α is the bulking factor you enter.
Is dam-body stability (sliding, overturning, foundation stress) checked?
Not on this page. The HydroStudio desktop edition includes a gravity check-dam stability module per Taiwan Soil and Water Conservation Technical Regulations Arts. 102–104 and Handbook §2.1 (self-weight, water and sediment pressure, uplift, seismic and debris-flow loads including boulder impact), with an alternative load set following Japan NILIM Technical Note No. 905.
Why provide a downstream apron and sub-dam?
The overflowing nappe falls onto the bed below the dam. An apron with an end sill, or a sub-dam that keeps a water cushion over the apron, absorbs the energy of the falling water and prevents scour from undermining the dam toe.
5. Explore All 30 Calculators (SI Edition; Design Basis Stated on Each Page)
Each calculator below states its own design basis on its page; several apply Taiwan regulations and say so.