HyGeoWorks
🔒 Previews run in your browser (WebAssembly) · Inputs are sent only when you formally export
ISO 80000-4 / NIST SP 811 Exact Factors · International Foot (0.3048 m)

US Customary & SI Civil Engineering Unit Converter (NIST SP 811)

Unit converter for seven quantities — pressure, force, line load, unit weight, bending moment, discharge and area — using the exact factors reported by the calculation core (1 ft = 0.3048 m, 1 lbf = 4.4482216 N, gn = 9.80665 m/s²). The conversion table lists every unit of the selected quantity to seven significant figures, including gravitational metric units (kgf, tf).

Standards and references (context for this calculation; the basis the calculator applies is the one stated below):

Design basis for this page ▾
ISO 80000-4 / NIST SP 811 Exact Conversion Factors (gn = 9.80665 m/s², 1 ft = 0.3048 m, 1 lbf = 4.4482216 N)

Design basis as reported by the calculation core: ISO 80000-4 / NIST SP 811 Exact Conversion Factors (gn = 9.80665 m/s², 1 ft = 0.3048 m, 1 lbf = 4.4482216 N)

Recalculates in your browser as you edit inputs; Free sample Word report and DXF for this calculator; With a license: formal Word and DXF export, plus online project reports from the Project List.

Interactive US Customary Engineering Workstation
US customary inputs, shown as US (SI) in the results
Free Samples and Pricing
A public sample produced by the production service from this page's standard example and sealed with a verification code: open it in Word or AutoCAD and check it on the Verify page. Not for PE sealing or submittal.
Single-export pass: US$19 for one calculator, 3 formal exports in total within 24 hours of the first; full credit toward an upgrade within 30 days, full refund before the first export
Single-export passes (one calculator, 3 exports within 24 hours), 30-day passes, annual plans and perpetual licenses; printable quotes for purchase orders.
Formal export and the Project List are on the workbench toolbar above:
Licensed users can formally export this calculator's Word report (with a verification code and server time witness) and AutoCAD DXF drawing, or add several calculators to the free Project List and export a multi-chapter project report online, with nothing to install on a Mac. Projects with DEM terrain or GIS files can run in the heavy cloud computation or in the HydroStudio desktop edition.
The summary lists the basis, key results and check verdicts; its first line marks it as an online preview, not for PE sealing or submittal.
Download the Offline Workbench (Single HTML File, 39 Tools)
No install and no email required. It contains the same calculation core as this site; results are also a preview, not for sealed submittals.

Check Summary Preview (Software Format; Auto-Populated)

Civil, Hydraulic & Geotechnical Engineering Unit Converter (US Customary ↔ SI): check summary (software format)
Calculation basis: ISO 80000-4 / NIST SP 811 Exact Conversion Factors (gn = 9.80665 m/s², 1 ft = 0.3048 m, 1 lbf = 4.4482216 N)
Check item Trial value Status
kPa (kN/m²)27579.03Calculated value
MPa (N/mm²)27.57903Calculated value
Pa27579029Calculated value
psi (lbf/in²)4000Calculated value

Summary of the online calculation (software format) for checking by the designer and an independent checker. Final submittals require review and seal by the licensed Professional Engineer in responsible charge.

Desktop edition: calculation reports and cross-module quantity reconciliation

1. Calculation reports: with a license, the desktop edition writes Word (.docx) and Excel (.xlsx) calculation reports and DXF drawings without the trial watermark, listing the inputs, the equations used and the results; in trial mode the step-by-step detail is hidden. For this calculator alone, licensed users can also sign in on the calculator above and formally export a single-tool Word report (with a verification code) and DXF drawing. The Pro plan (all modules) is US$990 per year; see Pricing for monthly, perpetual and team plans.
2. Cross-module reconciliation: desktop project runs carry the design peak flow into downstream channel, culvert and bridge hydraulics; terrain cut/fill into the earthwork balance, cost and carbon tables; structural concrete, formwork and rebar take-off into the cost and carbon tables; slope and excavation safety-factor thresholds into construction monitoring trigger levels.
3. Agency plan reviewers and university faculty can request a complimentary review or teaching license (link below).

Desktop pricing (Pro US$990/yr) Download the desktop trial Complimentary license for agency reviewers and faculty
Scope and responsibility: This page is a single-calculator trial run; cross-module quantity reconciliation is done in desktop project runs. Problems outside this calculator's scope (see the FAQ) need an appropriate analysis method. Final submittals require review and seal by a licensed Professional Engineer.

Governing Equations (US Customary Notation) & Basis Reported by the Calculation Core

The equations and limits the calculation core applies are listed below for independent checking.

Exact Base Definitions Used by the Calculation Core
1 ft = 0.3048 m (exact); 1 lbf = 4.4482216152605 N (exact); gn = 9.80665 m/s²; 1 acre = 43,560 sq ft
Derived factors: 1 kip = 4.448222 kN; 1 ksf = 47.88026 kPa; 1 pcf = 0.1570875 kN/m³; 1 cfs = 0.02831685 m³/s = 448.831 US gpm; 1 kgf = 9.80665 N.
International Foot vs. US Survey Foot
International foot = 0.3048 m (exact) vs. US survey foot = 1200 / 3937 m ≈ 0.3048006096 m (2 ppm longer)
The calculation core converts with the international foot only. The 2 ppm difference matters for large coordinates: on a State Plane easting of 2,000,000 ft it amounts to about 4 ft.

Worked Example: Converting a 4,000 psi Concrete Strength to SI and Gravitational Units

The worked example below was computed by the calculation core when this page was built; entering the same inputs above reproduces it. Verification cases, tolerances and actual differences for the calculation core are listed on the Benchmarks page.

Convert f'c = 4,000 psi to the pressure units listed by the calculation core: kPa, MPa, Pa, psf, ksf, bar, tf/m², kgf/cm², kgf/m² and meters of water head.

Every number in this example was produced by the calculation core (WebAssembly) when this page was built. The calculation core works in SI units: the US customary inputs below are converted with exact NIST SP 811 factors before the calculation, and results are shown in US customary units with the core's SI value in parentheses. Check values, criteria and calculation steps are the core's own SI output. Basis reported by the core: ISO 80000-4 / NIST SP 811 Exact Conversion Factors (gn = 9.80665 m/s², 1 ft = 0.3048 m, 1 lbf = 4.4482216 N)

1. Input Parameters

Design ParameterUS Customary ValueUnit
Physical QuantityStress / Bearing Pressure (psi, psf, ksf, kPa, MPa, bar, kgf/cm², tf/m², m of water)—
Input Magnitude4000—
Input Unitpsi (lbf/in.²)—

2. Computed Results (calculation core output)

OutputResult
kPa (kN/m²)27579.03
MPa (N/mm²)27.57903
Pa27579029
psi (lbf/in²)4000
psf (lbf/ft²)576000
ksf (kip/ft²)576
bar275.7903
tf/m²2812.278
kgf/cm²281.2278
kgf/m²2812278
mH2O (m water head at 4°C)2812.278

3. Calculation Steps (calculation core output, SI units)

[HyGeoWorks online preview - not for PE sealing or submittal]
4000 psi = 27579.03 kPa
Unit Conversion Table (11 rows)
UnitConverted Value
kPa (kN/m²)27579.03
MPa (N/mm²)27.57903
Pa27579029
psi (lbf/in²)4000(Input)
psf (lbf/ft²)576000
ksf (kip/ft²)576
bar275.7903
tf/m²2812.278
kgf/cm²281.2278
kgf/m²2812278
mH2O (m water head at 4°C)2812.278

Common US Customary Values Converted by the Calculation Core (computed when this page was built)

Inputs and outputs are listed with their units; conversion to and from SI is done by the calculation core.

US Customary Value (input)Converted by the Calculation CoreTypical Use
120 pcf18.8505 kN/m³Soil unit weight
150 pcf23.56312 kN/m³Normal-weight reinforced concrete
2 ksf (= 1 tsf)95.76052 kPa = 2000 psfBearing pressure
1 cfs448.8312 US gpm = 28.31685 L/sDischarge
10 acre40468.56 m² = 4.046856 haSite or catchment area

Frequently Asked Questions (Basis, Scope & Limits)

Common questions about this calculator and its basis are answered below. Final submittals require review and seal by a licensed Professional Engineer.

Why does the 2 ppm difference between the international foot and the US survey foot matter?

Over a 15-ft wall the difference is negligible, but State Plane coordinates often carry eastings above 2,000,000 ft, where 2 ppm is about 4 ft. Linework in international feet overlaid on survey-foot topography can therefore be offset by several feet. NIST and NOAA's National Geodetic Survey deprecated the US survey foot at the end of 2022, but it remains in older State Plane data. The calculation core converts with the international foot (0.3048 m) only.

Why does the converter also list tf/m², kgf/cm² and meters of water head?

The core's conversion table includes gravitational metric units (kgf, tf, with gn = 9.80665 m/s²) and water head, which appear in Taiwanese and Japanese codes and in older drawings. They help when checking references prepared in those units.

Does the converter round intermediate values?

The core converts through SI with the exact factors above and reports each converted value to seven significant figures in the conversion table.

Is tsf based on short tons (2,000 lbf) or metric tonnes?

In US geotechnical practice 1 tsf is one short ton per square foot: 2,000 psf = 2.0 ksf (95.76 kPa), close to atmospheric pressure (1 atm = 101.3 kPa ≈ 1.058 tsf). tsf is not in the core's unit list; enter twice the tsf value in ksf.

USD Pricing · Checkout by Stripe · Printable USD Quotation

From the Online Preview to the HydroStudio Desktop Edition: Reports Without the Trial Watermark

The free online preview is not for PE sealing or submittal and has no Word report, DXF drawing or verification code. Licensed users can sign in on the calculator and formally export a single-tool Word report (with a verification code) and DXF drawing. Several calculators can be combined in the Project List and exported online as a multi-chapter project report, and projects with terrain or GIS files can run in the heavy cloud computation. For interactive 2D models and large simulations, the HydroStudio desktop edition (Windows 10/11, 64-bit) opens the exported .toml project and, with a license, writes report.docx, a report.xlsx with live formulas and DXF drawings without the trial watermark. Sealing and submittal remain the responsibility of the licensed engineer.

Monthly
Pro monthly
$119 / month
One discipline: $69 / month. Renews monthly until canceled; cancel any time before the next renewal and keep using it to the end of the paid month.
Buy monthly ($119/mo)
30 days
30-day pass
$79 / 30 days, one discipline
All modules: $135. One payment; it does not renew. The pass fee can be credited once toward an annual or perpetual license of the same discipline or a higher plan bought within 30 days after the pass ends, with the same email and in the same currency.
Buy a 30-day pass (from $79)
Quotation
Printable USD quotation
For any plan, including Firm (from 3 seats) and Enterprise (from 10 seats), which are sold only to businesses and other organizations, not to individual buyers: print the quotation or save it as a PDF for your purchasing process.
Request a printable USD quotation

Compare all plans, including 90-day passes and perpetual licenses

Checkout is processed by Stripe; a tax ID can be entered at checkout, and for one-time payments Stripe issues an invoice showing the buyer's name and tax ID. Procurement follows your organization's own rules.

Explore All 31 Tools (20 US Customary + 11 Reference: Basis Stated on Each Page)

Need to edit terrain, 2D flood models and design alternatives interactively on your computer, or see 3D views drawn from your project data? Use the HydroStudio desktop edition:
Download the Desktop Trial
No credit card or phone number is needed to download. Without a license it runs as a trial: local calculation and 3D viewing work, exported reports and drawings carry a trial watermark (not for submittal), and some built-in data libraries are limited. Plans and prices are on the Pricing page.