Shallow Foundation Bearing Capacity Calculator (Meyerhof Equation with Vesić Nγ, FS ≥ 3.0)
Strip and wall footing bearing capacity calculator with US customary inputs (ft, pcf, psf, kip/ft). Evaluates the Meyerhof general bearing capacity equation on the effective width B' = B − 2|e| with the Vesić Nγ factor, Hansen depth factors and Meyerhof load inclination factors, and checks the bearing factor of safety against FS ≥ 3.0 — the core's default required factor of safety per Taiwan Soil and Water Conservation Technical Regulations Art. 120, item 3 (an allowable-stress check; no LRFD resistance-factor check is performed).
Standards and references (context for this calculation; the basis the calculator applies is the one stated below):
Design basis as reported by the calculation core: Meyerhof (1963) general bearing capacity equation with Vesić (1973) Nγ, Hansen (1970) depth factors and Meyerhof inclination factors, eccentricity by effective width; required factor of safety defaults to Taiwan Soil and Water Conservation Technical Regulations Art. 120, item 3
Recalculates in your browser as you edit inputs; Free sample Word report and DXF for this calculator; With a license: formal Word and DXF export, plus online project reports from the Project List.
Check Summary Preview (Software Format; Auto-Populated)
| Check item | Trial value | Status |
|---|---|---|
| Bearing Capacity Factor of Safety | 4.384 ≥ 3 | OK |
Summary of the online calculation (software format) for checking by the designer and an independent checker. Final submittals require review and seal by the licensed Professional Engineer in responsible charge.
Desktop edition: calculation reports and cross-module quantity reconciliation
1. Calculation reports: with a license, the desktop edition writes Word (.docx) and Excel (.xlsx) calculation reports and DXF drawings without the trial watermark, listing the inputs, the equations used and the results; in trial mode the step-by-step detail is hidden. For this calculator alone, licensed users can also sign in on the calculator above and formally export a single-tool Word report (with a verification code) and DXF drawing. The Pro plan (all modules) is US$990 per year; see Pricing for monthly, perpetual and team plans.
2. Cross-module reconciliation: desktop project runs carry the design peak flow into downstream channel, culvert and bridge hydraulics; terrain cut/fill into the earthwork balance, cost and carbon tables; structural concrete, formwork and rebar take-off into the cost and carbon tables; slope and excavation safety-factor thresholds into construction monitoring trigger levels.
3. Agency plan reviewers and university faculty can request a complimentary review or teaching license (link below).
Governing Equations (US Customary Notation) & Basis Reported by the Calculation Core
The equations and limits the calculation core applies are listed below for independent checking.
Worked Example: 6.0-ft Strip Footing at 4.0-ft Embedment on Medium-Dense Sand
The worked example below was computed by the calculation core when this page was built; entering the same inputs above reproduces it. Verification cases, tolerances and actual differences for the calculation core are listed on the Benchmarks page.
Compute the ultimate bearing capacity q_u, the allowable bearing capacity q_a (FS = 3.0) and the bearing factor of safety for a B = 6.0 ft strip footing embedded D_f = 4.0 ft in φ' = 32° granular soil (γ = 120 pcf below the base, 115 pcf above) carrying V = 20 kip/ft and H = 2 kip/ft at an eccentricity of 0.5 ft.
Every number in this example was produced by the calculation core (WebAssembly) when this page was built. The calculation core works in SI units: the US customary inputs below are converted with exact NIST SP 811 factors before the calculation, and results are shown in US customary units with the core's SI value in parentheses. Check values, criteria and calculation steps are the core's own SI output. Basis reported by the core: Meyerhof (1963) general bearing capacity equation with Vesić (1973) Nγ, Hansen (1970) depth factors and Meyerhof inclination factors, eccentricity by effective width; required factor of safety defaults to Taiwan Soil and Water Conservation Technical Regulations Art. 120, item 3
1. Input Parameters
| Design Parameter | US Customary Value | Unit |
|---|---|---|
| Footing Width B | 6 | ft |
| Embedment Depth D_f | 4 | ft |
| Effective Cohesion c' | 0 | psf |
| Soil Friction Angle φ' | 32 | ° |
| Unit Weight Below Base γ | 120 | pcf |
| Overburden Unit Weight γ_above | 115 | pcf |
| Vertical Line Load V | 20 | kip/ft |
| Horizontal Shear Load H | 2 | kip/ft |
| Load Eccentricity e | 0.5 | ft |
| Required Factor of Safety FS | 3 | — |
2. Computed Results (calculation core output)
| Output | Result |
|---|---|
| Bearing Factor Nc | 35.490 |
| Bearing Factor Nq | 23.177 |
| Bearing Factor Nγ | 30.215 |
| Effective Width B' | 5 ft (1.524 m) |
| Ultimate Bearing Capacity qu | 17540 psf (839.59 kPa) |
| Allowable Bearing Capacity qa | 5845 psf (279.86 kPa) |
| Bearing Factor of Safety FS | 4.384 |
Verification Checks (calculation core output)
| Verification Item | Computed Result | Governing Limit / Criterion | Status | Basis |
|---|---|---|---|---|
| Bearing Capacity Factor of Safety | 4.384 | ≥ 3 | PASS | Taiwan Soil and Water Conservation Technical Regulations Art. 120, item 3 |
3. Calculation Steps (calculation core output, SI units)
[HyGeoWorks online preview - not for PE sealing or submittal] Nq = e^(π·tanφ)·tan²(45° + φ/2) = 23.177; Nc = (Nq − 1)·cotφ = 35.490; Nγ = 2(Nq + 1)·tanφ = 30.215 Effective width B' = B − 2|e| = 1.8288 − 2×0.1524 = 1.524 m Df/B' = 0.8000 → k = 0.8000; Fqd = 1 + 2tanφ(1 − sinφ)²k = 1.2209; Fcd = 1.2309; Fγd = 1 ψ = tan⁻¹(H/V) = 5.711°; Fci = Fqi = (1 − ψ/90°)² = 0.8771; Fγi = (1 − ψ/φ)² = 0.6749 q = γ·Df = 22.025 kPa qu = c·Nc·Fcd·Fci + q·Nq·Fqd·Fqi + ½γB'Nγ·Fγd·Fγi = 0.00 + 546.66 + 292.93 = 839.59 kPa qa = qu/FS = 839.59/3 = 279.86 kPa; B' uniform bearing pressure V/B' = 291.878/1.524 = 191.52 kPa; FS = qu/(V/B') = 4.384
US customary equivalents (NIST SP 811 conversion of the SI values reported by the core above; the core summary itself is unchanged) Effective Width B' = 5 ft Ultimate Bearing Capacity qu = 17540 psf Allowable Bearing Capacity qa = 5845 psf
Frequently Asked Questions (Basis, Scope & Limits)
Common questions about this calculator and its basis are answered below. Final submittals require review and seal by a licensed Professional Engineer.
Why does the calculator use the uniform stress V / B' rather than the trapezoidal toe pressure q_max?
Meyerhof (1953) showed that bearing failure beneath an eccentrically loaded footing develops over a reduced effective width B' = B − 2e centered under the load. The calculation core therefore divides the vertical load by B' when it computes the bearing factor of safety.
Does this calculator perform an AASHTO LRFD factored bearing check (φ_b · q_n)?
No. The calculation core reports its basis as the Meyerhof (1963) general bearing capacity equation with Vesić (1973) Nγ, Hansen (1970) depth factors and Meyerhof inclination factors and checks a bearing factor of safety FS ≥ 3.0, a default taken from the Taiwan Soil and Water Conservation Technical Regulations Art. 120, item 3. An LRFD strength check with the resistance factor φ_b of your governing AASHTO edition or State DOT manual has to be made separately from the reported ultimate capacity q_u.
How does shallow groundwater affect γ and γ_above in the bearing equation?
When the water table rises to the footing base, the unit weight in the 0.5·γ·B'·N_γ term should be the buoyant unit weight γ' = γ_sat − 62.4 pcf, roughly halving that term. Enter the unit weights that correspond to the groundwater condition you are checking.
Does passing the bearing check guarantee acceptable settlement?
No. The calculator checks bearing capacity only and does not compute settlement. On granular soils, settlement limits often govern the usable bearing pressure, so check settlement with the method and limits of your governing code or agency.
From the Online Preview to the HydroStudio Desktop Edition: Reports Without the Trial Watermark
The free online preview is not for PE sealing or submittal and has no Word report, DXF drawing or verification code. Licensed users can sign in on the calculator and formally export a single-tool Word report (with a verification code) and DXF drawing. Several calculators can be combined in the Project List and exported online as a multi-chapter project report, and projects with terrain or GIS files can run in the heavy cloud computation. For interactive 2D models and large simulations, the HydroStudio desktop edition (Windows 10/11, 64-bit) opens the exported .toml project and, with a license, writes report.docx, a report.xlsx with live formulas and DXF drawings without the trial watermark. Sealing and submittal remain the responsibility of the licensed engineer.
Compare all plans, including 90-day passes and perpetual licenses