Cantilever & Gravity Retaining Wall Calculator — AASHTO LRFD Sec. 11 Strength Ia / Ib, State DOT φ Override & ACI 318
Retaining wall stability and RC check with US customary inputs (ft, in., pcf, psf, psi). The calculation core evaluates AASHTO LRFD Sec. 11 Strength Ia / Ib sliding, eccentricity and bearing (default φ_τ = 0.80, φ_b = 0.55; custom State DOT resistance factors can be entered and are flagged in the basis line of the result), reports the sliding and overturning factors of safety alongside, and tabulates ACI 318 flexural and shear design with ASTM A615 Grade 60 bars (#4 through #9). AASHTO LRFD 4th Ed. (2007) / FHWA-NHI-10-024 and FHWA-NHI-06-089 allowable stress design can be selected as alternative bases in the calculator.
Standards and references (context for this calculation; the basis the calculator applies is the one stated below):
Design basis as reported by the calculation core: FHWA GEC 11 (FHWA-HIF-24-002, 2023) / SCDOT GDM (2022) / MnDOT LRFD BDM — AASHTO LRFD Bridge Design Specifications Sec. 11 (9th Ed. 2020 values as published in these free federal/state manuals; not the 10th Ed. text)
Recalculates in your browser as you edit inputs; Free sample Word report and DXF for this calculator; With a license: formal Word and DXF export, plus online project reports from the Project List; 3D schematic: fixed example, not drawn from your inputs.
Check Summary Preview (Software Format; Auto-Populated)
| Check item | Trial value | Status |
|---|---|---|
| Strength Ia Sliding Resistance φτRn / Hu (φτ = 0.80) | 1.079 (Rd = 129.7, Ed = 120.2) ≥ 1.000 | OK |
| Strength Ia Eccentricity Limit |e|/B | 0.102 ≤ 0.333 | OK |
| Strength Ib Bearing Resistance φbRn / Vu (φb = 0.55) | 2.767 (Rd = 1109.5, Ed = 400.9) ≥ 1.000 | OK |
| Minimum concrete strength | 27.6 MPa — | ◇ Not judged Not judged: The general minimum strengths of ACI 318-19 and EN 1992-1-1 have not been verified against the original text, so no pass/fail judgement is made; the designer may specify a limit with fc_min_mpa. |
Summary of the online calculation (software format) for checking by the designer and an independent checker. Final submittals require review and seal by the licensed Professional Engineer in responsible charge.
Desktop edition: calculation reports and cross-module quantity reconciliation
1. Calculation reports: with a license, the desktop edition writes Word (.docx) and Excel (.xlsx) calculation reports and DXF drawings without the trial watermark, listing the inputs, the equations used and the results; in trial mode the step-by-step detail is hidden. For this calculator alone, licensed users can also sign in on the calculator above and formally export a single-tool Word report (with a verification code) and DXF drawing. The Pro plan (all modules) is US$990 per year; see Pricing for monthly, perpetual and team plans.
2. Cross-module reconciliation: desktop project runs carry the design peak flow into downstream channel, culvert and bridge hydraulics; terrain cut/fill into the earthwork balance, cost and carbon tables; structural concrete, formwork and rebar take-off into the cost and carbon tables; slope and excavation safety-factor thresholds into construction monitoring trigger levels.
3. Agency plan reviewers and university faculty can request a complimentary review or teaching license (link below).
Governing Equations (US Customary Notation) & Basis Reported by the Calculation Core
The equations and limits the calculation core applies are listed below for independent checking.
Worked Example: 15.0-ft CIP Cantilever Retaining Wall (B = 13.0 ft, #6 @ 8 in. o.c.)
The worked example below was computed by the calculation core when this page was built; entering the same inputs above reproduces it. Verification cases, tolerances and actual differences for the calculation core are listed on the Benchmarks page.
AASHTO LRFD Sec. 11 Strength Ia / Ib and ACI 318 check for an H = 15.0 ft cast-in-place RC retaining wall with a B = 13.0 ft base (2.5-ft toe, 1.5-ft stem, 9.0-ft heel), an 18 in. × 18 in. shear key, γ = 120 pcf granular backfill (φ' = 32°), a 250 psf live-load surcharge, f'c = 4,000 psi, and ASTM A615 Grade 60 #6 @ 8 in. o.c. stem steel.
Every number in this example was produced by the calculation core (WebAssembly) when this page was built. The calculation core works in SI units: the US customary inputs below are converted with exact NIST SP 811 factors before the calculation, and results are shown in US customary units with the core's SI value in parentheses. Check values, criteria and calculation steps are the core's own SI output. Basis reported by the core: FHWA GEC 11 (FHWA-HIF-24-002, 2023) / SCDOT GDM (2022) / MnDOT LRFD BDM — AASHTO LRFD Bridge Design Specifications Sec. 11 (9th Ed. 2020 values as published in these free federal/state manuals; not the 10th Ed. text)
1. Input Parameters
| Design Parameter | US Customary Value | Unit |
|---|---|---|
| Wall Structural Type | RC Inverted-T Wall | — |
| Total Wall Height H | 15 | ft |
| Stem Top Thickness | 1 | ft |
| Stem Base Thickness | 1.5 | ft |
| Footing Slab Thickness | 1.5 | ft |
| Toe Projection | 2.5 | ft |
| Heel Projection | 9 | ft |
| RC Unit Weight γc | 150 | pcf |
| Batter on Front Face | No | — |
| Backfill Unit Weight γ | 120 | pcf |
| Backfill Friction Angle φ' | 32 | ° |
| Backfill Surface Slope β | 0 | ° |
| Earth Pressure Theory | Rankine Theory | — |
| Live Load Surcharge q_LS | 250 | psf |
| Include Surcharge on Heel | No | — |
| Water Table Height Behind Wall hw | (blank) | ft |
| Saturated Backfill Unit Weight γsat | (blank) | pcf |
| Base Friction Coeff. μ = tanδ_b | 0.55 | — |
| Base Adhesion ca | 0 | psf |
| Foundation Material | Soil Foundation | — |
| Bearing Capacity Input Mode | Ultimate qu / FS | — |
| Nominal Bearing Resistance q_n | 12000 | psf |
| Front Passive Embedment Depth | 0 | ft |
| Passive Soil γ | 114.5858 | pcf |
| Passive Soil φ' | 30 | ° |
| Passive Mobilization Factor | 0.5 | — |
| Horizontal Seismic Coeff. kh | 0 | — |
| Vertical Seismic Coeff. kv | 0 | — |
| Monolithic Shear Key Depth | 1.5 | ft |
| Shear Key Width | 1.5 | ft |
| Shear Key Offset from Toe | 2.5 | ft |
| Key Base Sliding Plane | Segmented at key base (soil friction in front of the key, base friction behind it) | — |
| Concrete Strength f'c (ACI 318) | 4000 | psi |
| ASTM A615 Rebar Yield f_y | 60000 | psi |
| Stem Main Vertical Rebar | #6 (ASTM) | — |
| Stem Rebar Spacing (o.c.) | 8 | in |
| Toe Slab Rebar Size | #5 (ASTM) | — |
| Toe Rebar Spacing | 6 | in |
| Heel Slab Rebar Size | #6 (ASTM) | — |
| Heel Rebar Spacing | 8 | in |
| Stem Bar Curtailment Height, alternate bars | (blank) | ft |
| Nominal Maximum Aggregate Size | (blank) | in |
| Apply Size Effect λs to Footing Shear | No | — |
| Shear Key Main Bar | Selected by program | — |
| Shear Key Bar Spacing | (blank) | in |
| Key-to-Base Interface | Monolithic (μ = 1.4) | — |
| Key Design Horizontal Force | Automatic (passive pressure where present) | — |
| Wall Length | (blank) | ft |
2. Computed Results (calculation core output)
| Output | Result |
|---|---|
| Sliding Factor of Safety FS_s (static, unfactored) | 2.156 |
| Overturning Factor of Safety FS_o (static, unfactored) | 5.225 |
| Base Width B | 13 ft (3.962 m) |
| Max Toe Bearing Pressure q_max | 1986 psf (95.1 kPa) |
| LRFD Sliding CDR (φRn / Hu) | 1.079 |
| LRFD Bearing CDR (φRn / Vu) | 2.767 |
Verification Checks (calculation core output)
| Verification Item | Computed Result | Governing Limit / Criterion | Status | Basis |
|---|---|---|---|---|
| Strength Ia Sliding Resistance φτRn / Hu (φτ = 0.80) | 1.079 (Rd = 129.7, Ed = 120.2) | ≥ 1.000 | PASS | AASHTO LRFD Table 10.5.5.2.2-1; load factors Table 3.4.1-2 (9th Ed. via MnDOT LRFD BDM p.11-106 to 11-111, FHWA GEC 11 Table 18) |
| Strength Ia Eccentricity Limit |e|/B | 0.102 | ≤ 0.333 | PASS | AASHTO LRFD Art. 11.6.3.3 (9th Ed. via SCDOT GDM p.C-9, MnDOT p.11-52) |
| Strength Ib Bearing Resistance φbRn / Vu (φb = 0.55) | 2.767 (Rd = 1109.5, Ed = 400.9) | ≥ 1.000 | PASS | AASHTO LRFD Art. 11.6.3.2; φb = 0.55 per Table 11.5.7-1 (as reproduced in Colorado DOT BDM Example 11; same value in SCDOT GDM Table 9-6) |
| Minimum concrete strength | 27.6 MPa | — | ◇ Not judged Not judged: The general minimum strengths of ACI 318-19 and EN 1992-1-1 have not been verified against the original text, so no pass/fail judgement is made; the designer may specify a limit with fc_min_mpa. | ACI 318-19 / EN 1992-1-1 |
3. Calculation Steps (calculation core output, SI units)
[HyGeoWorks online preview - not for PE sealing or submittal] Base width B = 3.962 m, Earth pressure height H = 4.572 m [Strength I] Hd = 120.23 kN/m, Rh,d = 129.71 kN/m; Vd = 400.92 kN/m, Rv,d = 1109.47 kN/m; |ed|/B (sliding combination) = 0.102, (bearing combination) = 0.057; φ'd = 32.00°, μd = 0.550
US customary equivalents (NIST SP 811 conversion of the SI values reported by the core above; the core summary itself is unchanged) Base Width B = 13 ft Max Toe Bearing Pressure q_max = 1986 psf
Characteristic Resultants & Base Pressures (1 rows)
| Case | Ka | ΣV (kN/m) | ΣH (kN/m) | Mr (kN·m/m) | Mo (kN·m/m) | e (m) | qmax (kPa) | qmin (kPa) |
|---|---|---|---|---|---|---|---|---|
| Static / Persistent | 0.3073 | 303.24 | 77.35 | 682.90 | 130.70 | 0.160 | 95.1 | 58.0 |
RC Flexural & Shear Design (ACI 318: f'c = 4000 psi / 27.6 MPa, fy = 60000 psi / 414 MPa) (4 rows)
| Member | Mu (kN·m) | Vu (kN) | As,req (cm²) | As,min (cm²) | Rebar | φMn (kN·m) | φVc (kN) | Status |
|---|---|---|---|---|---|---|---|---|
| Stem base | 157.43 | 102.67 | 10.92 | 8.23 | #6 @ 8 in. o.c. | 200.01 | 259.44 | PASS |
| Toe Slab | 34.81 | 46.99 | 2.52 | 8.23 | #5 @ 6 in. o.c. | 176.62 | 148.36 | PASS |
| Heel Slab | 144.67 | 79.14 | 10.01 | 8.23 | #6 @ 8 in. o.c. | 200.01 | 157.86 | PASS |
| Shear key | 0.00 | 0.00 | 0.00 | 8.23 | #4 @ 6 in. o.c. (auto) | 115.75 | 115.02 | PASS |
Resistance Factors Applied by the Calculation Core, State DOT Overrides & ASTM A615 Rebar Reference
Inputs and outputs are listed with their units; conversion to and from SI is done by the calculation core.
| Basis Selected in the Calculator | Sliding φ_τ Used by the Core | Bearing φ_b Used by the Core | Eccentricity Limit on Soil | Where It Appears in the Result |
|---|---|---|---|---|
| AASHTO LRFD Sec. 11, 9th Edition values (default basis of this page) | 0.80 | 0.55 | |e| / B ≤ 1/3 (0.333) | Table 10.5.5.2.2-1 & Art. 11.6.3.3 |
| AASHTO LRFD 4th Ed. (2007) / FHWA-NHI-10-024 (selectable) | 1.00 | 0.65 | |e| / B ≤ 1/4 (0.250) | Table 11.5.7-1 & Art. 11.6.3.3 |
| State DOT Custom Override (entered by the engineer) | Value entered | Value entered | Limit of the selected basis | Basis line of the result is tagged as an override |
| ASTM A615 Gr. 60 Rebar (#4, #5, #6, #7, #8, #9) | f_y = 60,000 psi | A_b = 0.20, 0.31, 0.44, 0.60, 0.79, 1.00 in.² | Spacing entered in inches (e.g. 8 in. o.c.) | ACI 318 flexural / shear design table |
Frequently Asked Questions (Basis, Scope & Limits)
Common questions about this calculator and its basis are answered below. Final submittals require review and seal by a licensed Professional Engineer.
Which AASHTO LRFD edition and eccentricity limit does this calculator apply?
By default the calculation core reports its basis as FHWA GEC 11 (FHWA-HIF-24-002, 2023) / SCDOT GDM (2022) / MnDOT LRFD BDM, which reproduce the AASHTO LRFD Bridge Design Specifications Sec. 11 factors of the 9th Edition (2020); the text of the 10th Edition (2024) is not used. It checks the Strength Ia resultant eccentricity on soil against |e|/B ≤ 1/3 (0.333) with φ_τ = 0.80 and φ_b = 0.55. Selecting AASHTO LRFD 4th Ed. (2007) / FHWA-NHI-10-024 in the design-code selector switches the limit to |e|/B ≤ 1/4 (0.250) and the default factors to φ_τ = 1.00 and φ_b = 0.65. The basis line and every check row of the result name the edition that was actually applied.
What does the State DOT Custom Resistance Factor (φ_τ / φ_b) Override do?
A State DOT manual may specify resistance factors φ_τ and φ_b that differ from AASHTO Table 11.5.7-1. The calculator lets the engineer enter φ_τ, φ_b and the agency name; the calculation core then uses the entered factors, shows them in the check rows, and tags the basis line of the result as an override so the reviewer can see that the national default was not used.
How is the live-load surcharge (q_LS) modeled?
The surcharge is entered as a uniform pressure q_LS (psf) on the backfill; the worked example uses 250 psf. In the Strength I check the calculation core applies γ_LS = 1.75 to the share of the active thrust caused by the surcharge and γ_EH = 1.50 to the earth-pressure share.
Does the tool output US ASTM A615 rebar callouts (#4–#9 at inch spacings) rather than converted metric bars?
Yes. You select ASTM A615 Grade 60 bars (#4, #5, #6, #7, #8, #9) and enter the spacing in inches, and the RC design table of the result lists the bar callout (for example #6 @ 8 in. o.c.), φM_n, φV_c and the status of each member.
From the Online Preview to the HydroStudio Desktop Edition: Reports Without the Trial Watermark
The free online preview is not for PE sealing or submittal and has no Word report, DXF drawing or verification code. Licensed users can sign in on the calculator and formally export a single-tool Word report (with a verification code) and DXF drawing. Several calculators can be combined in the Project List and exported online as a multi-chapter project report, and projects with terrain or GIS files can run in the heavy cloud computation. For interactive 2D models and large simulations, the HydroStudio desktop edition (Windows 10/11, 64-bit) opens the exported .toml project and, with a license, writes report.docx, a report.xlsx with live formulas and DXF drawings without the trial watermark. Sealing and submittal remain the responsibility of the licensed engineer.
Compare all plans, including 90-day passes and perpetual licenses