FHWA HEC-22 Curb-Opening & Grate Inlet Interception Calculator
Roadway pavement drainage and storm drain inlet calculator with US customary inputs (ft, in., cfs). Evaluates the gutter spread width T, intercepted flow, capture efficiency and bypass carryover per FHWA HEC-22 (3rd/4th Ed.) Ch. 4, as reported by the calculation core.
Standards and references (context for this calculation; the basis the calculator applies is the one stated below):
Design basis as reported by the calculation core: FHWA HEC-22 Urban Drainage Design Manual (3rd/4th Ed.) Ch. 4 & US EPA SWMM 5.2 Inlet Module
Recalculates in your browser as you edit inputs; Free sample Word report and DXF for this calculator; With a license: formal Word and DXF export, plus online project reports from the Project List.
Check Summary Preview (Software Format; Auto-Populated)
| Check item | Trial value | Status |
|---|---|---|
| Gutter Spread Width T | 2.492 m | Calculated value |
| Intercepted Flow Qi | 0.09968 m³/s | Calculated value |
| Total Capture Efficiency E | 0.8801 | Calculated value |
| Bypass Carryover Flow Qb | 0.01358 m³/s | Calculated value |
Summary of the online calculation (software format) for checking by the designer and an independent checker. Final submittals require review and seal by the licensed Professional Engineer in responsible charge.
Desktop edition: calculation reports and cross-module quantity reconciliation
1. Calculation reports: with a license, the desktop edition writes Word (.docx) and Excel (.xlsx) calculation reports and DXF drawings without the trial watermark, listing the inputs, the equations used and the results; in trial mode the step-by-step detail is hidden. For this calculator alone, licensed users can also sign in on the calculator above and formally export a single-tool Word report (with a verification code) and DXF drawing. The Pro plan (all modules) is US$990 per year; see Pricing for monthly, perpetual and team plans.
2. Cross-module reconciliation: desktop project runs carry the design peak flow into downstream channel, culvert and bridge hydraulics; terrain cut/fill into the earthwork balance, cost and carbon tables; structural concrete, formwork and rebar take-off into the cost and carbon tables; slope and excavation safety-factor thresholds into construction monitoring trigger levels.
3. Agency plan reviewers and university faculty can request a complimentary review or teaching license (link below).
Governing Equations (US Customary Notation) & Basis Reported by the Calculation Core
The equations and limits the calculation core applies are listed below for independent checking.
Worked Example: 10-ft Depressed Curb-Opening Inlet on a 2.0% Grade (Q = 4.0 cfs)
The worked example below was computed by the calculation core when this page was built; entering the same inputs above reproduces it. Verification cases, tolerances and actual differences for the calculation core are listed on the Benchmarks page.
Evaluate the pavement spread width T, intercepted flow Q_i and bypass flow Q_b for a 10-ft curb-opening inlet with a 2.0-ft gutter and a 3-in. (0.25-ft) depression on a 2.0% grade with a 2.0% cross slope.
Every number in this example was produced by the calculation core (WebAssembly) when this page was built. The calculation core works in SI units: the US customary inputs below are converted with exact NIST SP 811 factors before the calculation, and results are shown in US customary units with the core's SI value in parentheses. Check values, criteria and calculation steps are the core's own SI output. Basis reported by the core: FHWA HEC-22 Urban Drainage Design Manual (3rd/4th Ed.) Ch. 4 & US EPA SWMM 5.2 Inlet Module
1. Input Parameters
| Design Parameter | US Customary Value | Unit |
|---|---|---|
| Inlet Location | On Continuous Grade | — |
| Inlet Configuration | Curb-Opening Inlet | — |
| Curb-Opening Length L | 10 | ft |
| Curb Throat Height h | 0.5 | ft |
| Curb Opening Throat | Horizontal | — |
| Gutter Approach Flow Q | 4 | cfs |
| Roadway Profile Grade S_L | 0.02 | m/m |
| Pavement Cross-Slope S_x | 0.02 | m/m |
| Pavement Manning's n | 0.016 | — |
| Concrete Gutter Width W | 2 | ft |
| Gutter Depression a | 0.25 | ft |
| Travel Lane / Crown Width | 12 | ft |
| Clogging Reduction Factor | 0 | — |
| Number of Inlets in Series | 1 | — |
2. Computed Results (calculation core output)
| Output | Result |
|---|---|
| Gutter Spread Width T | 8.175 ft (2.492 m) |
| Intercepted Flow Qi | 3.52 cfs (0.09968 m³/s) |
| Total Capture Efficiency E | 0.8801 |
| Bypass Carryover Flow Qb | 0.4797 cfs (0.01358 m³/s) |
3. Calculation Steps (calculation core output, SI units)
[HyGeoWorks online preview - not for PE sealing or submittal] Inlet type: Curb opening (3.05 m × height 0.15 m), On-grade; cross slope Sx = 0.02, pavement n = 0.016, gutter width W = 0.6096 m, gutter depression a = 0.0762 m On-grade S_L = 0.02, approach flow Q = 0.113267 m³/s → spread width T = 2.492 m (HEC-22 Eq. 4-2/4-4) intercepted flow Qi = 0.09968 m³/s (1 inlets in series, clogging = 0); bypass flow Qb = 0.01358 m³/s
US customary equivalents (NIST SP 811 conversion of the SI values reported by the core above; the core summary itself is unchanged) Gutter Spread Width T = 8.175 ft Intercepted Flow Qi = 3.52 cfs Bypass Carryover Flow Qb = 0.4797 cfs
Frequently Asked Questions (Basis, Scope & Limits)
Common questions about this calculator and its basis are answered below. Final submittals require review and seal by a licensed Professional Engineer.
Which HEC-22 edition and equations does this calculator use?
The calculation core reports its basis as FHWA HEC-22 Urban Drainage Design Manual (3rd/4th Ed.) Ch. 4 and uses the same inlet functions as the US EPA SWMM 5.2 inlet module. It reports one result set (spread, intercepted flow, capture efficiency and bypass); it does not produce an edition-by-edition comparison, so check any later-edition or agency-specific curb-opening revisions separately.
What gutter spread is allowed?
The calculator reports the spread T but applies no spread limit. The allowable spread depends on the road class and design storm set by the governing agency (State DOT or municipal drainage criteria); compare T with that limit.
How is inlet clogging handled?
The calculation core multiplies the intercepted flow by (1 − clogging factor). The worked example uses no clogging and one preset uses 20%; the calculator does not choose a factor for you, so use the clogging factor your agency prescribes for the inlet type and location.
Can the inlet be connected to a 2D flood model in the HydroStudio desktop edition?
Yes. In the HydroStudio desktop edition the 2D surface flood model exchanges flow with the 1D drainage network through inlets computed with the HEC-22 relations, and the network can be exported as an EPA SWMM .inp file. Verification cases are listed on the Benchmarks page.
From the Online Preview to the HydroStudio Desktop Edition: Reports Without the Trial Watermark
The free online preview is not for PE sealing or submittal and has no Word report, DXF drawing or verification code. Licensed users can sign in on the calculator and formally export a single-tool Word report (with a verification code) and DXF drawing. Several calculators can be combined in the Project List and exported online as a multi-chapter project report, and projects with terrain or GIS files can run in the heavy cloud computation. For interactive 2D models and large simulations, the HydroStudio desktop edition (Windows 10/11, 64-bit) opens the exported .toml project and, with a license, writes report.docx, a report.xlsx with live formulas and DXF drawings without the trial watermark. Sealing and submittal remain the responsibility of the licensed engineer.
Compare all plans, including 90-day passes and perpetual licenses