HyGeoWorks
🔒 Previews run in your browser (WebAssembly) · Inputs are sent only when you formally export
FHWA HEC-22 (3rd/4th Ed.) Ch. 4 · EPA SWMM 5.2 Inlet Module · 10-ft Curb Opening Example

FHWA HEC-22 Curb-Opening & Grate Inlet Interception Calculator

Roadway pavement drainage and storm drain inlet calculator with US customary inputs (ft, in., cfs). Evaluates the gutter spread width T, intercepted flow, capture efficiency and bypass carryover per FHWA HEC-22 (3rd/4th Ed.) Ch. 4, as reported by the calculation core.

Standards and references (context for this calculation; the basis the calculator applies is the one stated below):

Design basis for this page ▾
FHWA HEC-22 Urban Drainage Design Manual (3rd/4th Ed.) Ch. 4 & US EPA SWMM 5.2 Inlet Module

Design basis as reported by the calculation core: FHWA HEC-22 Urban Drainage Design Manual (3rd/4th Ed.) Ch. 4 & US EPA SWMM 5.2 Inlet Module

Recalculates in your browser as you edit inputs; Free sample Word report and DXF for this calculator; With a license: formal Word and DXF export, plus online project reports from the Project List.

Interactive US Customary Engineering Workstation
US customary inputs, shown as US (SI) in the results
Free Samples and Pricing
A public sample produced by the production service from this page's standard example and sealed with a verification code: open it in Word or AutoCAD and check it on the Verify page. Not for PE sealing or submittal.
Single-export pass: US$19 for one calculator, 3 formal exports in total within 24 hours of the first; full credit toward an upgrade within 30 days, full refund before the first export
Single-export passes (one calculator, 3 exports within 24 hours), 30-day passes, annual plans and perpetual licenses; printable quotes for purchase orders.
Formal export and the Project List are on the workbench toolbar above:
Licensed users can formally export this calculator's Word report (with a verification code and server time witness) and AutoCAD DXF drawing, or add several calculators to the free Project List and export a multi-chapter project report online, with nothing to install on a Mac. Projects with DEM terrain or GIS files can run in the heavy cloud computation or in the HydroStudio desktop edition.
The summary lists the basis, key results and check verdicts; its first line marks it as an online preview, not for PE sealing or submittal.
Download the Offline Workbench (Single HTML File, 39 Tools)
No install and no email required. It contains the same calculation core as this site; results are also a preview, not for sealed submittals.

Check Summary Preview (Software Format; Auto-Populated)

FHWA HEC-22 Curb & Grate Storm Drain Inlet Calculator: check summary (software format)
Calculation basis: FHWA HEC-22 Urban Drainage Design Manual (3rd/4th Ed.) Ch. 4 & US EPA SWMM 5.2 Inlet Module
Check item Trial value Status
Gutter Spread Width T2.492 mCalculated value
Intercepted Flow Qi0.09968 m³/sCalculated value
Total Capture Efficiency E0.8801Calculated value
Bypass Carryover Flow Qb0.01358 m³/sCalculated value

Summary of the online calculation (software format) for checking by the designer and an independent checker. Final submittals require review and seal by the licensed Professional Engineer in responsible charge.

Desktop edition: calculation reports and cross-module quantity reconciliation

1. Calculation reports: with a license, the desktop edition writes Word (.docx) and Excel (.xlsx) calculation reports and DXF drawings without the trial watermark, listing the inputs, the equations used and the results; in trial mode the step-by-step detail is hidden. For this calculator alone, licensed users can also sign in on the calculator above and formally export a single-tool Word report (with a verification code) and DXF drawing. The Pro plan (all modules) is US$990 per year; see Pricing for monthly, perpetual and team plans.
2. Cross-module reconciliation: desktop project runs carry the design peak flow into downstream channel, culvert and bridge hydraulics; terrain cut/fill into the earthwork balance, cost and carbon tables; structural concrete, formwork and rebar take-off into the cost and carbon tables; slope and excavation safety-factor thresholds into construction monitoring trigger levels.
3. Agency plan reviewers and university faculty can request a complimentary review or teaching license (link below).

Desktop pricing (Pro US$990/yr) Download the desktop trial Complimentary license for agency reviewers and faculty
Scope and responsibility: This page is a single-calculator trial run; cross-module quantity reconciliation is done in desktop project runs. Problems outside this calculator's scope (see the FAQ) need an appropriate analysis method. Final submittals require review and seal by a licensed Professional Engineer. Federal public-domain datasets cited pursuant to 17 U.S.C. § 105 (FHWA HEC-22; no official U.S. Government endorsement implied).

Governing Equations (US Customary Notation) & Basis Reported by the Calculation Core

The equations and limits the calculation core applies are listed below for independent checking.

Gutter Flow & Spread Equation (US Customary Form)
Q = (0.56 / n) · S_x^(5/3) · S_L^(1/2) · T^(8/3) [cfs] (uniform cross slope; K_u = 0.56)
T = water spread width from the curb face (ft); S_x = pavement cross slope (ft/ft); S_L = longitudinal grade (ft/ft); n = pavement roughness (0.016 in the worked example).
FHWA HEC-22 Curb-Opening Interception Length & Efficiency
L_T = 0.60 · Q^0.42 · S_L^0.30 · [1 / (n · S_e)]^0.60; Efficiency E = 1 − (1 − L / L_T)^1.8
L_T = curb-opening length required for 100% interception (ft); S_e = equivalent cross slope including the gutter depression; L = curb-opening length (ft).

Worked Example: 10-ft Depressed Curb-Opening Inlet on a 2.0% Grade (Q = 4.0 cfs)

The worked example below was computed by the calculation core when this page was built; entering the same inputs above reproduces it. Verification cases, tolerances and actual differences for the calculation core are listed on the Benchmarks page.

Evaluate the pavement spread width T, intercepted flow Q_i and bypass flow Q_b for a 10-ft curb-opening inlet with a 2.0-ft gutter and a 3-in. (0.25-ft) depression on a 2.0% grade with a 2.0% cross slope.

Every number in this example was produced by the calculation core (WebAssembly) when this page was built. The calculation core works in SI units: the US customary inputs below are converted with exact NIST SP 811 factors before the calculation, and results are shown in US customary units with the core's SI value in parentheses. Check values, criteria and calculation steps are the core's own SI output. Basis reported by the core: FHWA HEC-22 Urban Drainage Design Manual (3rd/4th Ed.) Ch. 4 & US EPA SWMM 5.2 Inlet Module

1. Input Parameters

Design ParameterUS Customary ValueUnit
Inlet LocationOn Continuous Grade—
Inlet ConfigurationCurb-Opening Inlet—
Curb-Opening Length L10ft
Curb Throat Height h0.5ft
Curb Opening ThroatHorizontal—
Gutter Approach Flow Q4cfs
Roadway Profile Grade S_L0.02m/m
Pavement Cross-Slope S_x0.02m/m
Pavement Manning's n0.016—
Concrete Gutter Width W2ft
Gutter Depression a0.25ft
Travel Lane / Crown Width12ft
Clogging Reduction Factor0—
Number of Inlets in Series1—

2. Computed Results (calculation core output)

OutputResult
Gutter Spread Width T8.175 ft (2.492 m)
Intercepted Flow Qi3.52 cfs (0.09968 m³/s)
Total Capture Efficiency E0.8801
Bypass Carryover Flow Qb0.4797 cfs (0.01358 m³/s)

3. Calculation Steps (calculation core output, SI units)

[HyGeoWorks online preview - not for PE sealing or submittal]
Inlet type: Curb opening (3.05 m × height 0.15 m), On-grade; cross slope Sx = 0.02, pavement n = 0.016, gutter width W = 0.6096 m, gutter depression a = 0.0762 m
On-grade S_L = 0.02, approach flow Q = 0.113267 m³/s → spread width T = 2.492 m (HEC-22 Eq. 4-2/4-4)
intercepted flow Qi = 0.09968 m³/s (1 inlets in series, clogging = 0); bypass flow Qb = 0.01358 m³/s
US customary equivalents (NIST SP 811 conversion of the SI values reported by the core above; the core summary itself is unchanged)
  Gutter Spread Width T = 8.175 ft
  Intercepted Flow Qi = 3.52 cfs
  Bypass Carryover Flow Qb = 0.4797 cfs

Frequently Asked Questions (Basis, Scope & Limits)

Common questions about this calculator and its basis are answered below. Final submittals require review and seal by a licensed Professional Engineer.

Which HEC-22 edition and equations does this calculator use?

The calculation core reports its basis as FHWA HEC-22 Urban Drainage Design Manual (3rd/4th Ed.) Ch. 4 and uses the same inlet functions as the US EPA SWMM 5.2 inlet module. It reports one result set (spread, intercepted flow, capture efficiency and bypass); it does not produce an edition-by-edition comparison, so check any later-edition or agency-specific curb-opening revisions separately.

What gutter spread is allowed?

The calculator reports the spread T but applies no spread limit. The allowable spread depends on the road class and design storm set by the governing agency (State DOT or municipal drainage criteria); compare T with that limit.

How is inlet clogging handled?

The calculation core multiplies the intercepted flow by (1 − clogging factor). The worked example uses no clogging and one preset uses 20%; the calculator does not choose a factor for you, so use the clogging factor your agency prescribes for the inlet type and location.

Can the inlet be connected to a 2D flood model in the HydroStudio desktop edition?

Yes. In the HydroStudio desktop edition the 2D surface flood model exchanges flow with the 1D drainage network through inlets computed with the HEC-22 relations, and the network can be exported as an EPA SWMM .inp file. Verification cases are listed on the Benchmarks page.

USD Pricing · Checkout by Stripe · Printable USD Quotation

From the Online Preview to the HydroStudio Desktop Edition: Reports Without the Trial Watermark

The free online preview is not for PE sealing or submittal and has no Word report, DXF drawing or verification code. Licensed users can sign in on the calculator and formally export a single-tool Word report (with a verification code) and DXF drawing. Several calculators can be combined in the Project List and exported online as a multi-chapter project report, and projects with terrain or GIS files can run in the heavy cloud computation. For interactive 2D models and large simulations, the HydroStudio desktop edition (Windows 10/11, 64-bit) opens the exported .toml project and, with a license, writes report.docx, a report.xlsx with live formulas and DXF drawings without the trial watermark. Sealing and submittal remain the responsibility of the licensed engineer.

Monthly
Pro monthly
$119 / month
One discipline: $69 / month. Renews monthly until canceled; cancel any time before the next renewal and keep using it to the end of the paid month.
Buy monthly ($119/mo)
30 days
30-day pass
$79 / 30 days, one discipline
All modules: $135. One payment; it does not renew. The pass fee can be credited once toward an annual or perpetual license of the same discipline or a higher plan bought within 30 days after the pass ends, with the same email and in the same currency.
Buy a 30-day pass (from $79)
Quotation
Printable USD quotation
For any plan, including Firm (from 3 seats) and Enterprise (from 10 seats), which are sold only to businesses and other organizations, not to individual buyers: print the quotation or save it as a PDF for your purchasing process.
Request a printable USD quotation

Compare all plans, including 90-day passes and perpetual licenses

Checkout is processed by Stripe; a tax ID can be entered at checkout, and for one-time payments Stripe issues an invoice showing the buyer's name and tax ID. Procurement follows your organization's own rules.

Explore All 31 Tools (20 US Customary + 11 Reference: Basis Stated on Each Page)

Need to edit terrain, 2D flood models and design alternatives interactively on your computer, or see 3D views drawn from your project data? Use the HydroStudio desktop edition:
Download the Desktop Trial