Check Summary Preview (Software Format; Auto-Populated)
| Check item | Trial value | Status |
|---|---|---|
| DA1 – Combination 1: A1 + M1 + R1 — Factored Stability FSd ≥ γR;e | 1.537 ≥ 1.000 | OK |
| DA1 – Combination 2: A2 + M2 + R1 — Factored Stability FSd ≥ γR;e | 1.341 ≥ 1.000 | OK |
Summary of the online calculation (software format) for checking by the designer and an independent checker. Final sign-off remains the responsibility of the chartered or registered engineer.
Desktop edition: calculation reports and cross-module quantity reconciliation
1. Calculation reports: with a licence, the desktop edition writes Word (.docx) and Excel (.xlsx) calculation reports and DXF drawings without the trial watermark, listing the inputs, the equations used and the results; in trial mode the step-by-step detail is hidden. For this calculator alone, licensed users can also sign in on the calculator above and formally export a single-tool Word report (with a verification code) and DXF drawing. The Pro plan (all modules) is US$990 per year; see Pricing for monthly, perpetual and team plans.
2. Cross-module reconciliation: desktop project runs carry the design peak flow into downstream channel, culvert and bridge hydraulics; terrain cut/fill into the earthwork balance, cost and carbon tables; structural concrete, formwork and rebar take-off into the cost and carbon tables; slope and excavation safety-factor thresholds into construction monitoring trigger levels.
3. Independent checking engineers, authority reviewers and academics can request a complimentary review or teaching licence (link below).
1. Governing Equations & SI Nomenclature
The equations the calculation core applies are summarised below for independent checking.
The equations below summarise the method that the calculation core applies on this page. The design basis it reports is: EN 1997-1:2004 §11 Design Approach 1 (Comb. 1 & Comb. 2). The worked example further down lists the core's own calculation steps for the standard example.
2. Worked Standard Example (Computed by the Calculation Core)
The worked example below was computed by the calculation core when this page was built; entering the same inputs above reproduces it.
Design Scenario — 8.0 m Slope at 1V:1.5H with a Water Table 2.0 m Above the Toe at the Crest: Determine the critical slip circle, the characteristic factor of safety and the EN 1997-1:2004 §11 Design Approach 1 stability ratios for an 8.0 m slope at 1V:1.5H (γ = 19 kN/m³, γsat = 20 kN/m³, c' = 10 kPa, φ' = 30°) with a water table height of 2.0 m at the crest.
The inputs below were passed to the calculation core (WebAssembly) when this page was built; every step, result and check shown here is the core's own output. Basis reported by the core: EN 1997-1:2004 §11 Design Approach 1 (Comb. 1 & Comb. 2)
Inputs Passed to the Calculation Core
| Parameter | Value | Unit |
|---|---|---|
| Slope Height H | 8 | m |
| Slope Ratio m (H:1V) | 1.5 | — |
| Soil Unit Weight γ | 19 | kN/m³ |
| Saturated Unit Weight γsat | 20 | kN/m³ |
| Cohesion c' | 10 | kPa |
| Friction Angle φ' | 30 | ° |
| Water Table Height at Crest | 2 | m |
| Horizontal Seismic Coeff. kh | 0 | — |
| Method | Simplified Bishop | — |
| Design Situation / Stage | Permanent / Long-Term | — |
| Loading Condition | Normal | — |
Calculation Steps (calculation core output)
[HyGeoWorks online preview - not for PE sealing or submittal]
- Toe x = 16.0 m, Crest x = 28.0 m; Search grid xc [12.0, 32.0], zc [9.6, 24.0], evaluated 913 slip circles
- Critical circle: center (18.67, 12.00) m, R = 12.34 m; entry x = 15.78 m, exit x = 30.34 m, characteristic FS = 1.676
- [DA1 – Combination 1: A1 + M1 + R1] Factored strength search (γφ'=1.00, c' divisor=1.350, γR,e=1.00) → FSd = 1.537
- [DA1 – Combination 2: A2 + M2 + R1] Factored strength search (γφ'=1.25, c' divisor=1.250, γR,e=1.00) → FSd = 1.341
Computed Results (calculation core output)
| Output Parameter | Calculated Value | SI Unit |
|---|---|---|
| Minimum Factor of Safety FS | 1.676 | — |
| Critical Circle Center xc | 18.67 | m |
| Critical Circle Center zc | 12.00 | m |
| Slip Circle Radius R | 12.34 | m |
| EC7 Factored Stability Ratio Rd/Ed | 1.341 | — |
Verification Checks (calculation core output)
| Verification Check | Computed Value | Criterion | Verdict | Basis |
|---|---|---|---|---|
| DA1 – Combination 1: A1 + M1 + R1 — Factored Stability FSd ≥ γR;e | 1.537 | ≥ 1.000 | OK | EN 1997-1:2004 §11.5.1; Tables A.3, A.4, A.14 |
| DA1 – Combination 2: A2 + M2 + R1 — Factored Stability FSd ≥ γR;e | 1.341 | ≥ 1.000 | OK | EN 1997-1:2004 §11.5.1; Tables A.3, A.4, A.14 |
Method of Slices Summary (30 rows)
| # | x (m) | α (°) | W (kN/m) | u·l | N' | S | c'l + N'tanφ' | z_base | z_top | b (m) |
|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 16.02 | -12.38 | 0.67 | 0.29 | 1.13 | 3.36 | 5.63 | -0.056 | 0.014 | 0.486 |
| 2 | 16.51 | -10.08 | 4.63 | 1.14 | 4.35 | 4.44 | 7.44 | -0.152 | 0.337 | 0.486 |
| 3 | 16.99 | -7.80 | 8.40 | 1.89 | 7.33 | 5.45 | 9.13 | -0.229 | 0.661 | 0.486 |
| 4 | 17.48 | -5.53 | 11.97 | 2.54 | 10.11 | 6.39 | 10.71 | -0.285 | 0.985 | 0.486 |
| 5 | 17.96 | -3.27 | 15.36 | 3.10 | 12.70 | 7.28 | 12.20 | -0.323 | 1.308 | 0.486 |
| 6 | 18.45 | -1.01 | 18.56 | 3.57 | 15.14 | 8.12 | 13.60 | -0.341 | 1.632 | 0.486 |
| 7 | 18.93 | 1.24 | 21.58 | 3.95 | 17.44 | 8.91 | 14.93 | -0.340 | 1.956 | 0.486 |
| 8 | 19.42 | 3.50 | 24.41 | 4.25 | 19.62 | 9.66 | 16.19 | -0.320 | 2.279 | 0.486 |
| 9 | 19.90 | 5.76 | 27.05 | 4.46 | 21.69 | 10.38 | 17.40 | -0.281 | 2.603 | 0.486 |
| 10 | 20.39 | 8.03 | 29.51 | 4.59 | 23.65 | 11.08 | 18.56 | -0.222 | 2.927 | 0.486 |
| 11 | 20.88 | 10.31 | 31.77 | 4.63 | 25.53 | 11.74 | 19.68 | -0.144 | 3.250 | 0.486 |
| 12 | 21.36 | 12.61 | 33.84 | 4.58 | 27.33 | 12.38 | 20.75 | -0.045 | 3.574 | 0.486 |
| 13 | 21.85 | 14.93 | 35.71 | 4.44 | 29.05 | 13.01 | 21.80 | 0.074 | 3.898 | 0.486 |
| 14 | 22.33 | 17.28 | 37.38 | 4.20 | 30.71 | 13.62 | 22.82 | 0.214 | 4.222 | 0.486 |
| 15 | 22.82 | 19.65 | 38.83 | 3.84 | 32.31 | 14.21 | 23.81 | 0.376 | 4.545 | 0.486 |
| 16 | 23.30 | 22.06 | 40.06 | 3.37 | 33.86 | 14.79 | 24.79 | 0.561 | 4.869 | 0.486 |
| 17 | 23.79 | 24.52 | 41.05 | 2.76 | 35.35 | 15.36 | 25.75 | 0.770 | 5.193 | 0.486 |
| 18 | 24.27 | 27.02 | 41.80 | 2.00 | 36.80 | 15.93 | 26.70 | 1.005 | 5.516 | 0.486 |
| 19 | 24.76 | 29.58 | 42.29 | 1.06 | 38.20 | 16.49 | 27.64 | 1.266 | 5.840 | 0.486 |
| 20 | 25.25 | 32.21 | 42.50 | 0.00 | 39.50 | 17.03 | 28.54 | 1.557 | 6.164 | 0.486 |
| 21 | 25.73 | 34.91 | 42.51 | 0.00 | 39.81 | 17.25 | 28.90 | 1.879 | 6.487 | 0.486 |
| 22 | 26.22 | 37.71 | 42.21 | 0.00 | 39.89 | 17.41 | 29.17 | 2.235 | 6.811 | 0.486 |
| 23 | 26.70 | 40.62 | 41.55 | 0.00 | 39.72 | 17.50 | 29.33 | 2.631 | 7.135 | 0.486 |
| 24 | 27.19 | 43.66 | 40.48 | 0.00 | 39.23 | 17.52 | 29.36 | 3.070 | 7.458 | 0.486 |
| 25 | 27.67 | 46.86 | 38.95 | 0.00 | 38.34 | 17.45 | 29.24 | 3.560 | 7.782 | 0.486 |
| 26 | 28.16 | 50.27 | 35.88 | 0.00 | 35.83 | 16.88 | 28.28 | 4.110 | 8.000 | 0.486 |
| 27 | 28.64 | 53.94 | 30.13 | 0.00 | 30.16 | 15.31 | 25.66 | 4.734 | 8.000 | 0.486 |
| 28 | 29.13 | 57.96 | 23.50 | 0.00 | 22.94 | 13.37 | 22.40 | 5.452 | 8.000 | 0.486 |
| 29 | 29.62 | 62.50 | 15.67 | 0.00 | 13.17 | 10.81 | 18.12 | 6.301 | 8.000 | 0.486 |
| 30 | 30.10 | 67.87 | 5.98 | 0.00 | -1.64 | 7.13 | 11.94 | 7.351 | 8.000 | 0.486 |
Assumptions and Limits Stated by the Calculation Core
- Each combination is recomputed with an equivalent model: under the single-source principle self-weight and water pressure are both multiplied by γG, which is equivalent to dividing c′ and su by γG·γM, dividing tanφ′ by γφ′ and multiplying surcharge by γQ/γG; the circular grid is searched again and a non-circular governing surface is recomputed with design values, taking the smaller.
- [Mechanical and geometric plausibility warning] Slice bases are too steep (maximum base inclination 67.9°); 1 slice(s) show tension in the effective normal force on the base (minimum N' = -1.64 kN/m). Cohesion puts the slices near the crest in tension; set a tension crack depth at the crest and rerun (desktop edition), or check where the slip surface enters and exits
3. Regional Design Options in This Edition: UK, EU, Singapore, Malaysia, Hong Kong & Australia
Symbols and units are SI unless stated otherwise.
- This calculator: the design basis is the one reported by the calculation core: EN 1997-1:2004 §11 Design Approach 1 (Comb. 1 & Comb. 2). The options listed below belong to the calculators named in each item.
- United Kingdom, Ireland & European Union: The retaining wall and slope stability calculators default to EN 1997-1:2004 Design Approach 1 (Combination 1 & Combination 2); the UK National Annex and 2nd-Gen EN 1997-1:2024 / EN 1997-3:2025 (MFA, and RFA for retaining walls) are selectable there, as are DA2 for retaining walls and DA3 for slopes. The retaining wall calculator lets γG, γQ and γφ' be overridden for a National Annex and designs metric H-bars (H10–H32) when concrete and steel strengths are entered.
- Singapore & Malaysia: The retaining wall calculator offers SS EN 1997-1:2010 with the Singapore National Annex, and the detention calculator offers a DID Malaysia MSMA 2nd Edition (2012) Equation 2.2 IDF rainfall mode besides directly entered design intensities.
- Hong Kong SAR: HyGeoWorks does not claim Hong Kong Buildings Department pre-accepted program status; the retaining wall calculator's HK GEO Geoguide 1 option shows the calculation core's steps and checks so that the result can be checked independently. With that option the calculation core applies the Geoguide 1 Table 6 and Table 7 partial factors at ULS and the §9.2.4 middle-third eccentricity check at SLS.
- Australia & New Zealand: No ARR 2019 IFD data is built in; design rainfall intensities for any AEP can be entered directly in the detention calculator. The HydroStudio desktop edition supports GDA2020 / MGA2020 zones 46–59 as well as WGS 84 / UTM zones.
4. Frequently Asked Questions
Common questions about this calculator are answered below. Final sign-off remains the responsibility of the chartered or registered engineer.
How is the Eurocode 7 overall stability check made?
For EN 1997-1:2004 §11 Design Approach 1 the calculation core checks two design factors of safety against γR,e = 1.00. Combination 1 (A1 + M1 + R1) multiplies self-weight and water pressure by γG = 1.35 under the single-source principle, which is evaluated as c'k divided by 1.35 and the surcharge multiplied by 1.50 / 1.35. Combination 2 (A2 + M2 + R1) divides c'k and tan φ'k by 1.25 and multiplies the surcharge by 1.30. The critical circle is searched again for each combination.
Can the result be checked by hand?
Yes. The page prints the slice table of the critical circle: slice position, base inclination α, weight W, pore force u·l, effective normal force N', mobilised shear S, resisting term c'l + N'tanφ' and slice width b, so equilibrium can be re-checked in a spreadsheet.
How do I know the search grid was large enough?
The calculation steps state the search grid of circle centres and the number of circles evaluated. If the critical centre lies on the edge of that grid, the true minimum may lie outside it. The core also warns about implausible slip geometry, such as very steep slice bases or tension on the slice base. The HydroStudio desktop edition flags a critical centre on the outer edge of the search grid.
How do I analyse layered ground, non-circular surfaces or reinforcement?
The HydroStudio desktop edition includes non-circular slip-surface analysis by the Janbu simplified, Spencer and Morgenstern–Price methods, ground anchors, soil nails, reinforcement and stabilising piles, and 2D finite-element seepage whose pore pressures can be used in the stability analysis.
5. Explore All 30 Calculators (SI Edition; Design Basis Stated on Each Page)