Check Summary Preview (Software Format; Auto-Populated)
| Check item | Trial value | Status |
|---|---|---|
| Bearing Capacity Factor of Safety | 5.578 ≥ 3 | OK |
Summary of the online calculation (software format) for checking by the designer and an independent checker. Final sign-off remains the responsibility of the chartered or registered engineer.
Desktop edition: calculation reports and cross-module quantity reconciliation
1. Calculation reports: with a licence, the desktop edition writes Word (.docx) and Excel (.xlsx) calculation reports and DXF drawings without the trial watermark, listing the inputs, the equations used and the results; in trial mode the step-by-step detail is hidden. For this calculator alone, licensed users can also sign in on the calculator above and formally export a single-tool Word report (with a verification code) and DXF drawing. The Pro plan (all modules) is US$990 per year; see Pricing for monthly, perpetual and team plans.
2. Cross-module reconciliation: desktop project runs carry the design peak flow into downstream channel, culvert and bridge hydraulics; terrain cut/fill into the earthwork balance, cost and carbon tables; structural concrete, formwork and rebar take-off into the cost and carbon tables; slope and excavation safety-factor thresholds into construction monitoring trigger levels.
3. Independent checking engineers, authority reviewers and academics can request a complimentary review or teaching licence (link below).
1. Governing Equations & SI Nomenclature
The equations the calculation core applies are summarised below for independent checking.
The equations below summarise the method that the calculation core applies on this page. The design basis it reports is: Meyerhof (1963) general bearing capacity equation with Vesić (1973) Nγ, Hansen (1970) depth factors and Meyerhof inclination factors, eccentricity by effective width; required factor of safety defaults to Taiwan Soil and Water Conservation Technical Regulations Art. 120, item 3. The worked example further down lists the core's own calculation steps for the standard example.
2. Worked Standard Example (Computed by the Calculation Core)
The worked example below was computed by the calculation core when this page was built; entering the same inputs above reproduces it.
Design Scenario — Eccentric & Inclined Load on a 2.50 m Strip Footing (V = 400 kN/m, H = 40 kN/m, e = 0.15 m): Compute the ultimate and allowable bearing capacity and check the bearing factor of safety against 3.0 for a 2.50 m wide strip footing embedded 1.00 m in silty sand (c' = 5 kPa, φ' = 32°, γ = 19 kN/m³ below the base, 18 kN/m³ above).
The inputs below were passed to the calculation core (WebAssembly) when this page was built; every step, result and check shown here is the core's own output. Basis reported by the core: Meyerhof (1963) general bearing capacity equation with Vesić (1973) Nγ, Hansen (1970) depth factors and Meyerhof inclination factors, eccentricity by effective width; required factor of safety defaults to Taiwan Soil and Water Conservation Technical Regulations Art. 120, item 3
Inputs Passed to the Calculation Core
| Parameter | Value | Unit |
|---|---|---|
| Footing Width B | 2.5 | m |
| Embedment Depth Df | 1 | m |
| Cohesion c' | 5 | kPa |
| Friction Angle φ' | 32 | ° |
| Soil Unit Weight γ | 19 | kN/m³ |
| Overburden Unit Weight γ | 18 | kN/m³ |
| Vertical Load V | 400 | kN/m |
| Horizontal Load H | 40 | kN/m |
| Load Eccentricity e | 0.15 | m |
| Required Factor of Safety FS | 3 | — |
Calculation Steps (calculation core output)
[HyGeoWorks online preview - not for PE sealing or submittal]
- Nq = e^(π·tanφ)·tan²(45° + φ/2) = 23.177; Nc = (Nq − 1)·cotφ = 35.490; Nγ = 2(Nq + 1)·tanφ = 30.215
- Effective width B' = B − 2|e| = 2.5 − 2×0.15 = 2.200 m
- Df/B' = 0.4545 → k = 0.4545; Fqd = 1 + 2tanφ(1 − sinφ)²k = 1.1255; Fcd = 1.1312; Fγd = 1
- ψ = tan⁻¹(H/V) = 5.711°; Fci = Fqi = (1 − ψ/90°)² = 0.8771; Fγi = (1 − ψ/φ)² = 0.6749
- q = γ·Df = 18.000 kPa
- qu = c·Nc·Fcd·Fci + q·Nq·Fqd·Fqi + ½γB'Nγ·Fγd·Fγi = 176.07 + 411.85 + 426.21 = 1014.13 kPa
- qa = qu/FS = 1014.13/3 = 338.04 kPa; B' uniform bearing pressure V/B' = 400/2.200 = 181.82 kPa; FS = qu/(V/B') = 5.578
Computed Results (calculation core output)
| Output Parameter | Calculated Value | SI Unit |
|---|---|---|
| Bearing Factor Nc | 35.490 | — |
| Bearing Factor Nq | 23.177 | — |
| Bearing Factor Nγ | 30.215 | — |
| Effective Width B' | 2.200 | m |
| Ultimate Bearing Capacity qu | 1014.13 | kPa |
| Allowable Bearing Capacity qa | 338.04 | kPa |
| Bearing Factor of Safety FS | 5.578 | — |
Verification Checks (calculation core output)
| Verification Check | Computed Value | Criterion | Verdict | Basis |
|---|---|---|---|---|
| Bearing Capacity Factor of Safety | 5.578 | ≥ 3 | OK | Taiwan Soil and Water Conservation Technical Regulations Art. 120, item 3 |
3. Regional Design Options in This Edition: UK, EU, Singapore, Malaysia, Hong Kong & Australia
Symbols and units are SI unless stated otherwise.
- This calculator: the design basis is the one reported by the calculation core: Meyerhof (1963) general bearing capacity equation with Vesić (1973) Nγ, Hansen (1970) depth factors and Meyerhof inclination factors, eccentricity by effective width; required factor of safety defaults to Taiwan Soil and Water Conservation Technical Regulations Art. 120, item 3. The options listed below belong to the calculators named in each item.
- United Kingdom, Ireland & European Union: The retaining wall and slope stability calculators default to EN 1997-1:2004 Design Approach 1 (Combination 1 & Combination 2); the UK National Annex and 2nd-Gen EN 1997-1:2024 / EN 1997-3:2025 (MFA, and RFA for retaining walls) are selectable there, as are DA2 for retaining walls and DA3 for slopes. The retaining wall calculator lets γG, γQ and γφ' be overridden for a National Annex and designs metric H-bars (H10–H32) when concrete and steel strengths are entered.
- Singapore & Malaysia: The retaining wall calculator offers SS EN 1997-1:2010 with the Singapore National Annex, and the detention calculator offers a DID Malaysia MSMA 2nd Edition (2012) Equation 2.2 IDF rainfall mode besides directly entered design intensities.
- Hong Kong SAR: HyGeoWorks does not claim Hong Kong Buildings Department pre-accepted program status; the retaining wall calculator's HK GEO Geoguide 1 option shows the calculation core's steps and checks so that the result can be checked independently. With that option the calculation core applies the Geoguide 1 Table 6 and Table 7 partial factors at ULS and the §9.2.4 middle-third eccentricity check at SLS.
- Australia & New Zealand: No ARR 2019 IFD data is built in; design rainfall intensities for any AEP can be entered directly in the detention calculator. The HydroStudio desktop edition supports GDA2020 / MGA2020 zones 46–59 as well as WGS 84 / UTM zones.
4. Frequently Asked Questions
Common questions about this calculator are answered below. Final sign-off remains the responsibility of the chartered or registered engineer.
Why does a horizontal load reduce bearing capacity so strongly?
The load inclination ψ = tan⁻¹(H/V) enters the inclination factors Fci = Fqi = (1 − ψ/90°)² and Fγi = (1 − ψ/φ')². Because Fγi depends on ψ/φ', even a small inclination reduces the γ term noticeably, which matters for walls and abutments with lateral loads.
Where does the required factor of safety of 3 come from?
It is an input. Its default of 3 follows Taiwan Soil and Water Conservation Technical Regulations Art. 120, item 3, as reported by the calculation core. Enter the factor required by your design code or authority; the allowable bearing capacity qa = qu/FS_req changes accordingly.
How should groundwater near the base be entered?
The calculator uses the unit weights you enter. Where the water table is at or above the base, enter the buoyant unit weight (saturated minus water) for the soil below the base, and for the overburden where it is submerged.
Does this calculator perform a Eurocode 7 check?
No. It reports the ultimate bearing capacity and a global factor of safety. The online Retaining Wall calculator performs EN 1997-1:2004 Design Approach 1 ULS bearing and sliding checks of a wall base, with the other selectable bases listed on that page.
5. Explore All 30 Calculators (SI Edition; Design Basis Stated on Each Page)