Check Summary Preview (Software Format; Auto-Populated)
| Check item | Trial value | Status |
|---|---|---|
| DA1 – Combination 1: A1 + M1 + R1 — ULS Sliding (Rd / Ed) | 1.291 (Rd = 157.0, Ed = 121.6) ≥ 1.000 | OK |
| DA1 – Combination 1: A1 + M1 + R1 — ULS Bearing (Rd / Ed) | 3.385 (Rd = 1304.1, Ed = 385.3) ≥ 1.000 | OK |
| DA1 – Combination 1: A1 + M1 + R1 — Base Eccentricity Ratio |ed|/B (Special Precaution Limit) | 0.080 ≤ 0.333 | OK |
| DA1 – Combination 2: A2 + M2 + R1 — ULS Sliding (Rd / Ed) | 1.087 (Rd = 125.6, Ed = 115.6) ≥ 1.000 | OK |
| DA1 – Combination 2: A2 + M2 + R1 — ULS Bearing (Rd / Ed) | 1.277 (Rd = 364.6, Ed = 285.4) ≥ 1.000 | OK |
| DA1 – Combination 2: A2 + M2 + R1 — Base Eccentricity Ratio |ed|/B (Special Precaution Limit) | 0.129 ≤ 0.333 | OK |
Summary of the online calculation (software format) for checking by the designer and an independent checker. Final sign-off remains the responsibility of the chartered or registered engineer.
Desktop edition: calculation reports and cross-module quantity reconciliation
1. Calculation reports: with a licence, the desktop edition writes Word (.docx) and Excel (.xlsx) calculation reports and DXF drawings without the trial watermark, listing the inputs, the equations used and the results; in trial mode the step-by-step detail is hidden. For this calculator alone, licensed users can also sign in on the calculator above and formally export a single-tool Word report (with a verification code) and DXF drawing. The Pro plan (all modules) is US$990 per year; see Pricing for monthly, perpetual and team plans.
2. Cross-module reconciliation: desktop project runs carry the design peak flow into downstream channel, culvert and bridge hydraulics; terrain cut/fill into the earthwork balance, cost and carbon tables; structural concrete, formwork and rebar take-off into the cost and carbon tables; slope and excavation safety-factor thresholds into construction monitoring trigger levels.
3. Independent checking engineers, authority reviewers and academics can request a complimentary review or teaching licence (link below).
1. Governing Equations & SI Nomenclature
The equations the calculation core applies are summarised below for independent checking.
The equations below summarise the method that the calculation core applies on this page. The design basis it reports is: EN 1997-1:2004 Design Approach 1 (DA1 Comb. 1 & Comb. 2). The worked example further down lists the core's own calculation steps for the standard example.
2. Worked Standard Example (Computed by the Calculation Core)
The worked example below was computed by the calculation core when this page was built; entering the same inputs above reproduces it.
Design Scenario — 5.0 m Cantilever RC Retaining Wall (B = 3.50 m): ULS verification of a 5.0 m high inverted-T reinforced concrete retaining wall on a 3.50 m base (0.80 m toe, 0.50 m stem base, 2.20 m heel) retaining backfill with γ = 19 kN/m³, φ' = 32° and a 10 kPa surcharge, under EN 1997-1:2004 Design Approach 1 (Comb. 1 & Comb. 2). Choosing another option in the code selector re-runs the same geometry in the calculation core; under the 2nd-Gen options the core reports reference values without a verdict, because the EN 1997-3 Clause 7 factors for retaining structures have not been obtained.
The inputs below were passed to the calculation core (WebAssembly) when this page was built; every step, result and check shown here is the core's own output. Basis reported by the core: EN 1997-1:2004 Design Approach 1 (DA1 Comb. 1 & Comb. 2)
Inputs Passed to the Calculation Core
| Parameter | Value | Unit |
|---|---|---|
| Wall Structural Type | RC Inverted-T Wall | — |
| Total Wall Height H | 5 | m |
| Stem Top Thickness | 0.3 | m |
| Stem Base Thickness | 0.5 | m |
| Base Slab Thickness | 0.5 | m |
| Toe Projection Length | 0.8 | m |
| Heel Projection Length | 2.2 | m |
| RC Unit Weight γc | 25 | kN/m³ |
| Batter on Front Face | No | — |
| Backfill Unit Weight γ | 19 | kN/m³ |
| Backfill Friction Angle φ' | 32 | ° |
| Backfill Surface Slope β | 0 | ° |
| Earth Pressure Theory | Rankine Theory | — |
| Uniform Surcharge Load q | 10 | kPa |
| Include Surcharge on Heel | No | — |
| Water Table Height Behind Wall hw | (blank) | m |
| Saturated Backfill Unit Weight γsat | (blank) | kN/m³ |
| Base Sliding Friction μ | 0.55 | — |
| Base Adhesion ca | 0 | kPa |
| Foundation Material | Soil Foundation | — |
| Bearing Capacity Input Mode | Meyerhof Bearing Formula | — |
| Foundation Cohesion c' | 0 | kPa |
| Foundation Friction Angle φ' | 32 | ° |
| Foundation Soil γ | 19 | kN/m³ |
| Embedment Depth Df | 1 | m |
| Overburden Soil γ | 18 | kN/m³ |
| Front Passive Embedment Depth | 0 | m |
| Passive Soil γ | 18 | kN/m³ |
| Passive Soil φ' | 30 | ° |
| Passive Mobilization Factor | 0.5 | — |
| Horizontal Seismic Coeff. kh | 0 | — |
| Vertical Seismic Coeff. kv | 0 | — |
| Shear Key Depth | (blank) | m |
| Shear Key Width | (blank) | m |
| Shear Key Offset from Toe | (blank) | m |
| Key Base Sliding Plane | Segmented at key base (soil friction in front of the key, base friction behind it) | — |
| Concrete Strength f'c | (blank) | kgf/cm² |
| Rebar Yield Strength fy | (blank) | kgf/cm² |
| Stem Main Rebar Size | H16 (BS/EN) | — |
| Stem Rebar Spacing | (blank) | cm |
| Toe Slab Rebar Size | H16 (BS/EN) | — |
| Toe Rebar Spacing | (blank) | cm |
| Heel Slab Rebar Size | H16 (BS/EN) | — |
| Heel Rebar Spacing | (blank) | cm |
| Stem Bar Curtailment Height, alternate bars | (blank) | m |
| Nominal Maximum Aggregate Size | (blank) | cm |
| Apply Size Effect λs to Footing Shear | No | — |
| Shear Key Main Bar | Selected by program | — |
| Shear Key Bar Spacing | (blank) | cm |
| Key-to-Base Interface | Monolithic (μ = 1.4) | — |
| Key Design Horizontal Force | Automatic (passive pressure where present) | — |
| Wall Length | (blank) | m |
Calculation Steps (calculation core output)
[HyGeoWorks online preview - not for PE sealing or submittal]
- Base width B = 3.500 m, Earth pressure height H = 5.000 m
- [DA1 – Combination 1: A1 + M1 + R1] Hd = 121.56 kN/m, Rh,d = 156.97 kN/m; Vd = 385.29 kN/m, Rv,d = 1304.07 kN/m; |ed|/B (sliding combination) = 0.138, (bearing combination) = 0.080; φ'd = 32.00°, μd = 0.550
- [DA1 – Combination 2: A2 + M2 + R1] Hd = 115.57 kN/m, Rh,d = 125.58 kN/m; Vd = 285.40 kN/m, Rv,d = 364.55 kN/m; |ed|/B (sliding combination) = 0.129, (bearing combination) = 0.129; φ'd = 26.56°, μd = 0.440
Computed Results (calculation core output)
| Output Parameter | Calculated Value | SI Unit |
|---|---|---|
| Sliding Factor of Safety FS_s (static, unfactored) | 1.777 | — |
| Overturning Factor of Safety FS_o (static, unfactored) | 3.648 | — |
| Base Width B | 3.500 | m |
| Max Toe Bearing Pressure q_max | 118.6 | kPa |
| Max ULS Utilization Ratio Λ | 0.920 | — |
Verification Checks (calculation core output)
| Verification Check | Computed Value | Criterion | Verdict | Basis |
|---|---|---|---|---|
| DA1 – Combination 1: A1 + M1 + R1 — ULS Sliding (Rd / Ed) | 1.291 (Rd = 157.0, Ed = 121.6) | ≥ 1.000 | OK | EN 1997-1:2004 §6.5.3; Annex A Tables A.3, A.4, A.13 |
| DA1 – Combination 1: A1 + M1 + R1 — ULS Bearing (Rd / Ed) | 3.385 (Rd = 1304.1, Ed = 385.3) | ≥ 1.000 | OK | EN 1997-1:2004 §6.5.2; Annex D; Table A.13 |
| DA1 – Combination 1: A1 + M1 + R1 — Base Eccentricity Ratio |ed|/B (Special Precaution Limit) | 0.080 | ≤ 0.333 | OK | EN 1997-1:2004 §6.5.4 |
| DA1 – Combination 2: A2 + M2 + R1 — ULS Sliding (Rd / Ed) | 1.087 (Rd = 125.6, Ed = 115.6) | ≥ 1.000 | OK | EN 1997-1:2004 §6.5.3; Annex A Tables A.3, A.4, A.13 |
| DA1 – Combination 2: A2 + M2 + R1 — ULS Bearing (Rd / Ed) | 1.277 (Rd = 364.6, Ed = 285.4) | ≥ 1.000 | OK | EN 1997-1:2004 §6.5.2; Annex D; Table A.13 |
| DA1 – Combination 2: A2 + M2 + R1 — Base Eccentricity Ratio |ed|/B (Special Precaution Limit) | 0.129 | ≤ 0.333 | OK | EN 1997-1:2004 §6.5.4 |
| EQU — Overturning (Estb / Edst) | 2.208 (Rd = 525.4, Ed = 238.0) | ≥ 1.000 | OK | EN 1997-1:2004 §2.4.7.2; Tables A.2, A.4 |
Characteristic Resultants & Base Pressures (1 rows)
| Case | Ka | ΣV (kN/m) | ΣH (kN/m) | Mr (kN·m/m) | Mo (kN·m/m) | e (m) | qmax (kPa) | qmin (kPa) |
|---|---|---|---|---|---|---|---|---|
| Static / Persistent | 0.3073 | 285.40 | 88.34 | 583.74 | 160.03 | 0.265 | 118.6 | 44.4 |
3. Regional Design Options in This Edition: UK, EU, Singapore, Malaysia, Hong Kong & Australia
Symbols and units are SI unless stated otherwise.
- This calculator: the design basis is the one reported by the calculation core: EN 1997-1:2004 Design Approach 1 (DA1 Comb. 1 & Comb. 2). The options listed below belong to the calculators named in each item.
- United Kingdom, Ireland & European Union: The retaining wall and slope stability calculators default to EN 1997-1:2004 Design Approach 1 (Combination 1 & Combination 2); the UK National Annex and 2nd-Gen EN 1997-1:2024 / EN 1997-3:2025 (MFA, and RFA for retaining walls) are selectable there, as are DA2 for retaining walls and DA3 for slopes. The retaining wall calculator lets γG, γQ and γφ' be overridden for a National Annex and designs metric H-bars (H10–H32) when concrete and steel strengths are entered.
- Singapore & Malaysia: The retaining wall calculator offers SS EN 1997-1:2010 with the Singapore National Annex, and the detention calculator offers a DID Malaysia MSMA 2nd Edition (2012) Equation 2.2 IDF rainfall mode besides directly entered design intensities.
- Hong Kong SAR: HyGeoWorks does not claim Hong Kong Buildings Department pre-accepted program status; the retaining wall calculator's HK GEO Geoguide 1 option shows the calculation core's steps and checks so that the result can be checked independently. With that option the calculation core applies the Geoguide 1 Table 6 and Table 7 partial factors at ULS and the §9.2.4 middle-third eccentricity check at SLS.
- Australia & New Zealand: No ARR 2019 IFD data is built in; design rainfall intensities for any AEP can be entered directly in the detention calculator. The HydroStudio desktop edition supports GDA2020 / MGA2020 zones 46–59 as well as WGS 84 / UTM zones.
4. Frequently Asked Questions
Common questions about this calculator are answered below. Final sign-off remains the responsibility of the chartered or registered engineer.
Why does EN 1997-1 Design Approach 1 check two combinations?
The two combinations factor different things. Combination 1 (A1 + M1 + R1) factors the actions (γG = 1.35, γQ = 1.50) with unfactored soil strength; Combination 2 (A2 + M2 + R1) factors the soil strength (γφ' = 1.25) with γG = 1.00 and γQ = 1.30. Which one governs depends on the case, so the calculation core reports both, each with its utilisation for sliding and bearing.
How are the 2nd-generation EN 1997-1:2024 / EN 1997-3:2025 approaches checked?
With the MFA option the calculation core evaluates verification cases (a) VC1 + M1 and (b) VC3 + M2 of EN 1997-3 Table 5.2; with the RFA option it evaluates (d) VC1 with resistance factors γR,T = 1.1 for sliding and γR,N = 1.4 for bearing. Table 5.2 covers spread foundations and the Clause 7 factors for retaining structures have not been obtained, so these rows are reference values without a pass/fail verdict.
Is HyGeoWorks a Hong Kong Buildings Department pre-accepted program?
No, and it does not claim to be. With the Geoguide 1 option the calculation core applies the Table 6 and Table 7 partial factors at ULS and the §9.2.4 middle-third eccentricity check at SLS, and the page shows the core's steps and checks. The free online page is a preview not for submittal; licensed users can formally export a single-tool Word report online, and the HydroStudio desktop edition produces whole-project calculation reports.
How is base eccentricity checked?
Under the Eurocode 7 options the core checks the design eccentricity |ed|/B of the bearing combination against 1/3, the limit beyond which EN 1997-1 §6.5.4 calls for special precautions, and computes bearing on the effective width B' = B − 2|ed|. Under the Geoguide 1 option it checks the middle-third rule |e|/B ≤ 1/6 at SLS (§9.2.4).
5. Explore All 30 Calculators (SI Edition; Design Basis Stated on Each Page)
Each calculator below states its own design basis on its page; several apply Taiwan regulations and say so.