Cantilever & Gravity Retaining Wall Stability Calculator (Eurocode 7 & HK Geoguide 1)

ULS sliding and bearing checks and a base eccentricity check under EN 1997-1:2004 Design Approach 1 by default. The design-code selector also offers the UK and Singapore National Annexes, DA2, 2nd-Gen EN 1997-1:2024 / EN 1997-3:2025 (MFA or RFA), HK GEO Geoguide 1 and AASHTO LRFD / FHWA ASD options, and γG, γQ and γφ' can be overridden for a National Annex. When concrete and steel strengths are entered, an RC flexural and shear design table for metric H-bars is added.

Methods and references reported by the calculation core for this page (items marked selectable are options in the design-code selector):

Design basis and scope notes for this page ▾
EN 1997-1:2004 Design Approach 1 (DA1 Comb. 1 & Comb. 2) — defaultBS EN 1997-1:2004 + UK National Annex — selectableSS EN 1997-1:2010 + Singapore National Annex — selectableEN 1997-1:2004 Design Approach 2 (DA2) — selectableEN 1997-3:2025 Table 5.2 (2nd Gen Eurocode 7 — MFA (a) VC1+M1 & (b) VC3+M2) — selectableEN 1997-3:2025 Table 5.2 (2nd Gen Eurocode 7 — RFA (d) VC1) — selectableGeoguide 1: Guide to Retaining Wall Design (2nd Ed., e-version 2020) Tables 6 & 7 — selectable
Design basis as reported by the calculation core: EN 1997-1:2004 Design Approach 1 (DA1 Comb. 1 & Comb. 2)
Hong Kong note: HyGeoWorks does not claim Hong Kong Buildings Department pre-accepted program status. With the HK GEO Geoguide 1 option selected, the calculation core applies the Geoguide 1 Table 6 and Table 7 partial factors at ULS and the §9.2.4 middle-third eccentricity check at SLS; this page shows the core's calculation steps and checks so that the result can be checked independently.

Recalculates in your browser as you edit inputs; Free sample Word report and DXF for this calculator; With a licence: formal Word and DXF export, plus online project reports from the Project List; 3D schematic: fixed example, not drawn from your inputs.

Free samples and pricing
A public sample produced by the production service from this page's standard example and sealed with a verification code: open it in Word or AutoCAD and check it on the Verify page. Not for formal submission.
Single-export pass: US$19 for one calculator, 3 formal exports in total within 24 hours of the first; full credit toward an upgrade within 30 days, full refund before the first export
Single-export passes (one calculator, 3 exports within 24 hours), 30-day passes, annual plans and perpetual licences; printable quotes for purchase orders.
Formal export and the Project List are on the workbench toolbar above:
Licensed users can formally export this calculator's Word report (with a verification code and server time witness) and AutoCAD DXF drawing, or add several calculators to the free Project List and export a multi-chapter project report online, with nothing to install on a Mac. Projects with DEM terrain or GIS files can run in the heavy cloud computation or in the HydroStudio desktop edition.
The summary lists the basis, key results and check verdicts; its first line marks it as an online preview, not for formal submission.
Download the offline workbench (single HTML file, 39 tools)
No install and no email required. It contains the same calculation core as this site; results are also a preview, not for formal submission.

Check Summary Preview (Software Format; Auto-Populated)

Cantilever & Gravity Retaining Wall Stability Calculator (Eurocode 7 & HK Geoguide 1): check summary (software format)
Calculation basis: EN 1997-1:2004 Design Approach 1 (DA1 Comb. 1 & Comb. 2)
Check item Trial value Status
DA1 – Combination 1: A1 + M1 + R1 — ULS Sliding (Rd / Ed)1.291 (Rd = 157.0, Ed = 121.6) ≥ 1.000OK
DA1 – Combination 1: A1 + M1 + R1 — ULS Bearing (Rd / Ed)3.385 (Rd = 1304.1, Ed = 385.3) ≥ 1.000OK
DA1 – Combination 1: A1 + M1 + R1 — Base Eccentricity Ratio |ed|/B (Special Precaution Limit)0.080 ≤ 0.333OK
DA1 – Combination 2: A2 + M2 + R1 — ULS Sliding (Rd / Ed)1.087 (Rd = 125.6, Ed = 115.6) ≥ 1.000OK
DA1 – Combination 2: A2 + M2 + R1 — ULS Bearing (Rd / Ed)1.277 (Rd = 364.6, Ed = 285.4) ≥ 1.000OK
DA1 – Combination 2: A2 + M2 + R1 — Base Eccentricity Ratio |ed|/B (Special Precaution Limit)0.129 ≤ 0.333OK

Summary of the online calculation (software format) for checking by the designer and an independent checker. Final sign-off remains the responsibility of the chartered or registered engineer.

Desktop edition: calculation reports and cross-module quantity reconciliation

1. Calculation reports: with a licence, the desktop edition writes Word (.docx) and Excel (.xlsx) calculation reports and DXF drawings without the trial watermark, listing the inputs, the equations used and the results; in trial mode the step-by-step detail is hidden. For this calculator alone, licensed users can also sign in on the calculator above and formally export a single-tool Word report (with a verification code) and DXF drawing. The Pro plan (all modules) is US$990 per year; see Pricing for monthly, perpetual and team plans.
2. Cross-module reconciliation: desktop project runs carry the design peak flow into downstream channel, culvert and bridge hydraulics; terrain cut/fill into the earthwork balance, cost and carbon tables; structural concrete, formwork and rebar take-off into the cost and carbon tables; slope and excavation safety-factor thresholds into construction monitoring trigger levels.
3. Independent checking engineers, authority reviewers and academics can request a complimentary review or teaching licence (link below).

Desktop pricing (Pro US$990/yr) Download the desktop trial Complimentary licence for checkers, reviewers and academics
Scope and responsibility: This page is a single-calculator trial run; cross-module quantity reconciliation is done in desktop project runs. Problems outside this calculator's scope (see the FAQ) need an appropriate analysis method. Final sign-off remains the responsibility of the chartered or registered engineer.

1. Governing Equations & SI Nomenclature

The equations the calculation core applies are summarised below for independent checking.

The equations below summarise the method that the calculation core applies on this page. The design basis it reports is: EN 1997-1:2004 Design Approach 1 (DA1 Comb. 1 & Comb. 2). The worked example further down lists the core's own calculation steps for the standard example.

EN 1997-1:2004 Design Approach 1 (default)
Comb. 1 (A1 + M1 + R1): γG = 1.35 (unfavourable) / 1.00 (favourable), γQ = 1.50, γφ' = 1.00; Comb. 2 (A2 + M2 + R1): γG = 1.00, γQ = 1.30, γφ' = γc' = 1.25; γR,h = γR,v = 1.00
Earth pressures are recomputed with the design strength φ'd; the self-weight of the wall and of the soil on the heel is a favourable action for sliding, and the base friction uses the design value tan δd = tan δk / γφ' (§6.5.3(10)). ULS sliding Hd ≤ Rh,d (§6.5.3; base adhesion not counted) and bearing Vd ≤ Rv,d from EN 1997-1 Annex D on the effective width B' = B − 2|ed| (§6.5.2); the design eccentricity of the bearing combination |ed|/B ≤ 1/3 (§6.5.4).
2nd-Gen EN 1997-3:2025 Table 5.2 (selectable, reference only)
MFA: (a) VC1 + M1 and (b) VC3 + M2; RFA: (d) VC1 with γR,T = 1.1 (sliding) and γR,N = 1.4 (bearing)
Table 5.2 gives the factors for spread foundations. The retaining-structure factors of EN 1997-3 Clause 7 have not been obtained, so the calculation core reports each combination as a reference value without a pass/fail verdict, and exporting this option as a desktop project is refused.
HK GEO Geoguide 1 (selectable)
ULS (Tables 6 & 7): γf,surcharge = 1.5, γm = 1.2; SLS (§9.2.4): |e| / B ≤ 1/6
Sliding and bearing are reported as resistance-to-load ratios Rh,d / Hd and Rv,d / Vd ≥ 1.0.

2. Worked Standard Example (Computed by the Calculation Core)

The worked example below was computed by the calculation core when this page was built; entering the same inputs above reproduces it.

Design Scenario — 5.0 m Cantilever RC Retaining Wall (B = 3.50 m): ULS verification of a 5.0 m high inverted-T reinforced concrete retaining wall on a 3.50 m base (0.80 m toe, 0.50 m stem base, 2.20 m heel) retaining backfill with γ = 19 kN/m³, φ' = 32° and a 10 kPa surcharge, under EN 1997-1:2004 Design Approach 1 (Comb. 1 & Comb. 2). Choosing another option in the code selector re-runs the same geometry in the calculation core; under the 2nd-Gen options the core reports reference values without a verdict, because the EN 1997-3 Clause 7 factors for retaining structures have not been obtained.

The inputs below were passed to the calculation core (WebAssembly) when this page was built; every step, result and check shown here is the core's own output. Basis reported by the core: EN 1997-1:2004 Design Approach 1 (DA1 Comb. 1 & Comb. 2)

Inputs Passed to the Calculation Core

ParameterValueUnit
Wall Structural TypeRC Inverted-T Wall—
Total Wall Height H5m
Stem Top Thickness0.3m
Stem Base Thickness0.5m
Base Slab Thickness0.5m
Toe Projection Length0.8m
Heel Projection Length2.2m
RC Unit Weight γc25kN/m³
Batter on Front FaceNo—
Backfill Unit Weight γ19kN/m³
Backfill Friction Angle φ'32°
Backfill Surface Slope β0°
Earth Pressure TheoryRankine Theory—
Uniform Surcharge Load q10kPa
Include Surcharge on HeelNo—
Water Table Height Behind Wall hw(blank)m
Saturated Backfill Unit Weight γsat(blank)kN/m³
Base Sliding Friction μ0.55—
Base Adhesion ca0kPa
Foundation MaterialSoil Foundation—
Bearing Capacity Input ModeMeyerhof Bearing Formula—
Foundation Cohesion c'0kPa
Foundation Friction Angle φ'32°
Foundation Soil γ19kN/m³
Embedment Depth Df1m
Overburden Soil γ18kN/m³
Front Passive Embedment Depth0m
Passive Soil γ18kN/m³
Passive Soil φ'30°
Passive Mobilization Factor0.5—
Horizontal Seismic Coeff. kh0—
Vertical Seismic Coeff. kv0—
Shear Key Depth(blank)m
Shear Key Width(blank)m
Shear Key Offset from Toe(blank)m
Key Base Sliding PlaneSegmented at key base (soil friction in front of the key, base friction behind it)—
Concrete Strength f'c(blank)kgf/cm²
Rebar Yield Strength fy(blank)kgf/cm²
Stem Main Rebar SizeH16 (BS/EN)—
Stem Rebar Spacing(blank)cm
Toe Slab Rebar SizeH16 (BS/EN)—
Toe Rebar Spacing(blank)cm
Heel Slab Rebar SizeH16 (BS/EN)—
Heel Rebar Spacing(blank)cm
Stem Bar Curtailment Height, alternate bars(blank)m
Nominal Maximum Aggregate Size(blank)cm
Apply Size Effect λs to Footing ShearNo—
Shear Key Main BarSelected by program—
Shear Key Bar Spacing(blank)cm
Key-to-Base InterfaceMonolithic (μ = 1.4)—
Key Design Horizontal ForceAutomatic (passive pressure where present)—
Wall Length(blank)m

Calculation Steps (calculation core output)

[HyGeoWorks online preview - not for PE sealing or submittal]

  1. Base width B = 3.500 m, Earth pressure height H = 5.000 m
  2. [DA1 – Combination 1: A1 + M1 + R1] Hd = 121.56 kN/m, Rh,d = 156.97 kN/m; Vd = 385.29 kN/m, Rv,d = 1304.07 kN/m; |ed|/B (sliding combination) = 0.138, (bearing combination) = 0.080; φ'd = 32.00°, μd = 0.550
  3. [DA1 – Combination 2: A2 + M2 + R1] Hd = 115.57 kN/m, Rh,d = 125.58 kN/m; Vd = 285.40 kN/m, Rv,d = 364.55 kN/m; |ed|/B (sliding combination) = 0.129, (bearing combination) = 0.129; φ'd = 26.56°, μd = 0.440

Computed Results (calculation core output)

Output ParameterCalculated ValueSI Unit
Sliding Factor of Safety FS_s (static, unfactored)1.777—
Overturning Factor of Safety FS_o (static, unfactored)3.648—
Base Width B3.500m
Max Toe Bearing Pressure q_max118.6kPa
Max ULS Utilization Ratio Λ0.920—

Verification Checks (calculation core output)

Verification CheckComputed ValueCriterionVerdictBasis
DA1 – Combination 1: A1 + M1 + R1 — ULS Sliding (Rd / Ed)1.291 (Rd = 157.0, Ed = 121.6)≥ 1.000OKEN 1997-1:2004 §6.5.3; Annex A Tables A.3, A.4, A.13
DA1 – Combination 1: A1 + M1 + R1 — ULS Bearing (Rd / Ed)3.385 (Rd = 1304.1, Ed = 385.3)≥ 1.000OKEN 1997-1:2004 §6.5.2; Annex D; Table A.13
DA1 – Combination 1: A1 + M1 + R1 — Base Eccentricity Ratio |ed|/B (Special Precaution Limit)0.080≤ 0.333OKEN 1997-1:2004 §6.5.4
DA1 – Combination 2: A2 + M2 + R1 — ULS Sliding (Rd / Ed)1.087 (Rd = 125.6, Ed = 115.6)≥ 1.000OKEN 1997-1:2004 §6.5.3; Annex A Tables A.3, A.4, A.13
DA1 – Combination 2: A2 + M2 + R1 — ULS Bearing (Rd / Ed)1.277 (Rd = 364.6, Ed = 285.4)≥ 1.000OKEN 1997-1:2004 §6.5.2; Annex D; Table A.13
DA1 – Combination 2: A2 + M2 + R1 — Base Eccentricity Ratio |ed|/B (Special Precaution Limit)0.129≤ 0.333OKEN 1997-1:2004 §6.5.4
EQU — Overturning (Estb / Edst)2.208 (Rd = 525.4, Ed = 238.0)≥ 1.000OKEN 1997-1:2004 §2.4.7.2; Tables A.2, A.4
Characteristic Resultants & Base Pressures (1 rows)
CaseKaΣV (kN/m)ΣH (kN/m)Mr (kN·m/m)Mo (kN·m/m)e (m)qmax (kPa)qmin (kPa)
Static / Persistent0.3073285.4088.34583.74160.030.265118.644.4

3. Regional Design Options in This Edition: UK, EU, Singapore, Malaysia, Hong Kong & Australia

Symbols and units are SI unless stated otherwise.

4. Frequently Asked Questions

Common questions about this calculator are answered below. Final sign-off remains the responsibility of the chartered or registered engineer.

Why does EN 1997-1 Design Approach 1 check two combinations?

The two combinations factor different things. Combination 1 (A1 + M1 + R1) factors the actions (γG = 1.35, γQ = 1.50) with unfactored soil strength; Combination 2 (A2 + M2 + R1) factors the soil strength (γφ' = 1.25) with γG = 1.00 and γQ = 1.30. Which one governs depends on the case, so the calculation core reports both, each with its utilisation for sliding and bearing.

How are the 2nd-generation EN 1997-1:2024 / EN 1997-3:2025 approaches checked?

With the MFA option the calculation core evaluates verification cases (a) VC1 + M1 and (b) VC3 + M2 of EN 1997-3 Table 5.2; with the RFA option it evaluates (d) VC1 with resistance factors γR,T = 1.1 for sliding and γR,N = 1.4 for bearing. Table 5.2 covers spread foundations and the Clause 7 factors for retaining structures have not been obtained, so these rows are reference values without a pass/fail verdict.

Is HyGeoWorks a Hong Kong Buildings Department pre-accepted program?

No, and it does not claim to be. With the Geoguide 1 option the calculation core applies the Table 6 and Table 7 partial factors at ULS and the §9.2.4 middle-third eccentricity check at SLS, and the page shows the core's steps and checks. The free online page is a preview not for submittal; licensed users can formally export a single-tool Word report online, and the HydroStudio desktop edition produces whole-project calculation reports.

How is base eccentricity checked?

Under the Eurocode 7 options the core checks the design eccentricity |ed|/B of the bearing combination against 1/3, the limit beyond which EN 1997-1 §6.5.4 calls for special precautions, and computes bearing on the effective width B' = B − 2|ed|. Under the Geoguide 1 option it checks the middle-third rule |e|/B ≤ 1/6 at SLS (§9.2.4).

From the Online Preview to the HydroStudio Desktop Edition

The free preview has no Word report, DXF drawing or verification code. Licensed users can sign in on the calculator and formally export a single-tool Word report (with a verification code) and DXF drawing, or combine several calculators in the Project List and export a multi-chapter project report online; projects with terrain or GIS files can run in the heavy cloud computation, and interactive 2D models and large simulations use the desktop edition. Export a .toml project file from the calculator and open it in the HydroStudio desktop edition (Windows 10/11, 64-bit); fields that the online tool does not cover are marked as placeholders and must be completed there before calculating. With a licence, the desktop edition writes Word (.docx) calculation reports, Excel (.xlsx) workbooks with live formulas and .dxf drawings without the trial watermark, and also includes 2D shallow-water flood modelling (Godunov finite volume) and 2D finite-element variably saturated seepage.

✓ USD checkout via Stripe  ·  ✓ Printable USD quotation (print or save as PDF)  ·  ✓ Ed25519-signed licence with a 14-day offline lease
Desktop Licence Pricing (USD)
$990 USD / year (Pro, all modules)
Also available: Pro monthly at $119/month, a single-discipline annual licence at $590/yr and a 30-day single-discipline pass at $79. Purchasing approval follows your organisation's own rules.
View USD Pricing & Printable Quotation →

5. Explore All 30 Calculators (SI Edition; Design Basis Stated on Each Page)

Each calculator below states its own design basis on its page; several apply Taiwan regulations and say so.

Open-Channel & Pipe Hydraulics
Manning Open-Channel & Circular Pipe Flow Calculator
Open calculator
Open-Channel & Pipe Hydraulics
Manning Normal Depth (yn) & Critical Depth (yc) Calculator
Open calculator
Open-Channel & Pipe Hydraulics
Pipe Diameter & Channel Bottom Width Sizing Calculator
Open calculator
Stormwater Detention & Roadway Drainage
Detention Outlet Orifice & Rectangular Weir Sizing Calculator
Open calculator
Stormwater Detention & Roadway Drainage
Gutter Flow Spread & Kerb / Grate Inlet Interception Calculator
Open calculator
Open-Channel & Pipe Hydraulics
Box & Circular Pipe Culvert Inlet / Outlet Control Calculator
Open calculator
Energy Dissipation & Scour Protection
Culvert & Drain Outlet Riprap Apron Sizing Calculator
Open calculator
Energy Dissipation & Scour Protection
Drop Structure & Weir Plunge-Pool Scour Depth Calculator
Open calculator
Geotechnical & Retaining Structures
Shallow Strip Foundation Bearing Capacity Calculator
Open calculator
Geotechnical & Retaining Structures
Rainfall Infiltration & Shallow Infinite-Slope Stability FS(t) Calculator
Open calculator
Geotechnical & Retaining Structures
Laterally Loaded Pile Calculator
Open calculator
Engineering Utilities
Civil, Structural & Hydraulic Engineering Unit Converter
Open calculator
Geotechnical & Retaining Structures
Cantilever & Gravity Retaining Wall Stability Calculator
Open calculator
Geotechnical & Retaining Structures
Circular Slope Stability Calculator — Bishop's Simplified Method
Open calculator
Geotechnical & Retaining Structures
SPT Soil Liquefaction Triggering Calculator
Open calculator
Energy Dissipation & Scour Protection
Gravity Check Dam Spillway, Freeboard & Downstream Apron Calculator
Open calculator
Stormwater Detention & Roadway Drainage
On-Site Stormwater Detention Volume Calculator
Open calculator
Energy Dissipation & Scour Protection
Vertical Drop Structure & Stilling Basin Sizing Calculator
Open calculator
Energy Dissipation & Scour Protection
Steep-Slope Drainage Channel Drop-Step Spacing Calculator
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
Bridge Crossing: Backwater and Scour
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
Box Culvert Structural Design
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
Liquid-Retaining Structure Design
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
PAS 2080 Carbon Screening
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
Counterfort Retaining Wall RC Design
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
Elasto-Plastic Diaphragm Wall Staged Excavation
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
Pile Cap Shear and Reinforcement
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
Storm Sewer Longitudinal Profile, HGL & Utility Clearance Check
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
Road Alignment Check
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
AASHTO 1993 Flexible Pavement Structural Number (SN) Check
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
Formwork Shoring (Steel Tube Posts) Check
Open calculator
Need to edit terrain, 2D flood models and design alternatives interactively on your computer, or see 3D views drawn from your project data? Use the HydroStudio desktop edition:
Download the desktop trial
No credit card or phone number is needed to download. Without a licence it runs as a trial: local calculation and 3D viewing work, exported reports and drawings carry a trial watermark (not for submission), and some built-in data libraries are limited. Plans and prices are on the Pricing page.