Check Summary Preview (Software Format; Auto-Populated)
| Check item | Trial value | Status |
|---|---|---|
| Required Orifice Diameter D_req | 0.2454 m | Calculated value |
| Adopted Orifice Diameter D | 0.245 m | Calculated value |
| Actual Outflow Q | 0.1495 m³/s | Calculated value |
Summary of the online calculation (software format) for checking by the designer and an independent checker. Final sign-off remains the responsibility of the chartered or registered engineer.
Desktop edition: calculation reports and cross-module quantity reconciliation
1. Calculation reports: with a licence, the desktop edition writes Word (.docx) and Excel (.xlsx) calculation reports and DXF drawings without the trial watermark, listing the inputs, the equations used and the results; in trial mode the step-by-step detail is hidden. For this calculator alone, licensed users can also sign in on the calculator above and formally export a single-tool Word report (with a verification code) and DXF drawing. The Pro plan (all modules) is US$990 per year; see Pricing for monthly, perpetual and team plans.
2. Cross-module reconciliation: desktop project runs carry the design peak flow into downstream channel, culvert and bridge hydraulics; terrain cut/fill into the earthwork balance, cost and carbon tables; structural concrete, formwork and rebar take-off into the cost and carbon tables; slope and excavation safety-factor thresholds into construction monitoring trigger levels.
3. Independent checking engineers, authority reviewers and academics can request a complimentary review or teaching licence (link below).
1. Governing Equations & SI Nomenclature
The equations the calculation core applies are summarised below for independent checking.
The equations below summarise the method that the calculation core applies on this page. The design basis it reports is: Orifice Q = Cd·A·√(2gH) & Sharp/Broad-Crested Rectangular Weir Q = Cw·L·H^1.5. The worked example further down lists the core's own calculation steps for the standard example.
2. Worked Standard Example (Computed by the Calculation Core)
The worked example below was computed by the calculation core when this page was built; entering the same inputs above reproduces it.
Design Scenario — Single Orifice for an Allowable Release of 0.150 m³/s at H = 1.50 m: Size one circular orifice (Cd = 0.61) so that the outflow does not exceed 0.150 m³/s at a water depth of 1.50 m above the orifice invert, rounding the diameter down in 5 mm increments.
The inputs below were passed to the calculation core (WebAssembly) when this page was built; every step, result and check shown here is the core's own output. Basis reported by the core: Orifice Q = Cd·A·√(2gH) & Sharp/Broad-Crested Rectangular Weir Q = Cw·L·H^1.5
Inputs Passed to the Calculation Core
| Parameter | Value | Unit |
|---|---|---|
| Outlet Structure Type | Circular Orifice | — |
| Allowable Release Q | 0.15 | m³/s |
| Head H | 1.5 | m |
| Orifice Discharge Coeff. Cd | 0.61 | — |
| Number of Openings | 1 | — |
| Rounding Increment | 0.005 | m |
Calculation Steps (calculation core output)
[HyGeoWorks online preview - not for PE sealing or submittal]
- Submerged / full orifice flow: Q = N·Cd·(πD²/4)·√(2g(H − D/2)), N = 1, Cd = 0.61, H = 1.5 m → D = 0.2454 m (check Q = 0.1500 m³/s)
- Adopt D = 0.245 m (to the nearest 0.005 m, rounded down) -> Q = 0.1495 m³/s ≤ 0.15
Computed Results (calculation core output)
| Output Parameter | Calculated Value | SI Unit |
|---|---|---|
| Required Orifice Diameter D_req | 0.2454 | m |
| Adopted Orifice Diameter D | 0.245 | m |
| Actual Outflow Q | 0.1495 | m³/s |
3. Regional Design Options in This Edition: UK, EU, Singapore, Malaysia, Hong Kong & Australia
Symbols and units are SI unless stated otherwise.
- This calculator: the design basis is the one reported by the calculation core: Orifice Q = Cd·A·√(2gH) & Sharp/Broad-Crested Rectangular Weir Q = Cw·L·H^1.5. The options listed below belong to the calculators named in each item.
- United Kingdom, Ireland & European Union: The retaining wall and slope stability calculators default to EN 1997-1:2004 Design Approach 1 (Combination 1 & Combination 2); the UK National Annex and 2nd-Gen EN 1997-1:2024 / EN 1997-3:2025 (MFA, and RFA for retaining walls) are selectable there, as are DA2 for retaining walls and DA3 for slopes. The retaining wall calculator lets γG, γQ and γφ' be overridden for a National Annex and designs metric H-bars (H10–H32) when concrete and steel strengths are entered.
- Singapore & Malaysia: The retaining wall calculator offers SS EN 1997-1:2010 with the Singapore National Annex, and the detention calculator offers a DID Malaysia MSMA 2nd Edition (2012) Equation 2.2 IDF rainfall mode besides directly entered design intensities.
- Hong Kong SAR: HyGeoWorks does not claim Hong Kong Buildings Department pre-accepted program status; the retaining wall calculator's HK GEO Geoguide 1 option shows the calculation core's steps and checks so that the result can be checked independently. With that option the calculation core applies the Geoguide 1 Table 6 and Table 7 partial factors at ULS and the §9.2.4 middle-third eccentricity check at SLS.
- Australia & New Zealand: No ARR 2019 IFD data is built in; design rainfall intensities for any AEP can be entered directly in the detention calculator. The HydroStudio desktop edition supports GDA2020 / MGA2020 zones 46–59 as well as WGS 84 / UTM zones.
4. Frequently Asked Questions
Common questions about this calculator are answered below. Final sign-off remains the responsibility of the chartered or registered engineer.
Why does this calculator round the orifice diameter or weir length down?
The allowable release is an upper limit. Rounding the size up would let the actual outflow exceed it, so the calculation core rounds down to the entered increment and reports the actual outflow of the adopted size, which is at or below the allowable value.
How is the head H defined?
For an orifice, H is measured from the orifice invert (lowest edge) to the water level, and the core uses the head on the orifice centre, H − D/2. When the water level is below the orifice crown (H < D) the core treats the opening as partly full. For a weir, H is the head above the crest.
Which discharge coefficients should I use?
Cd and Cw are inputs. The defaults (Cd = 0.61, Cw = 1.84 m⁰·⁵/s) are values commonly used for sharp-edged openings and sharp-crested weirs; use the coefficients required by your authority or measured for the actual outlet. A minimum orifice size against blockage is not checked here.
What about tailwater and storage routing?
This page sizes a single outlet at one head without tailwater. The HydroStudio desktop edition includes level-pool routing of detention ponds with time-varying tailwater, flap gates and multiple outlets, and exports EPA SWMM .inp files.
5. Explore All 30 Calculators (SI Edition; Design Basis Stated on Each Page)
Each calculator below states its own design basis on its page; several apply Taiwan regulations and say so.