Check Summary Preview (Software Format; Auto-Populated)
| Check item | Trial value | Status |
|---|---|---|
| Flow Area A | 0.9600 m² | Calculated value |
| Wetted Perimeter P | 2.6971 m | Calculated value |
| Hydraulic Radius R | 0.3559 m | Calculated value |
| Flow Velocity V | 2.368 m/s | Calculated value |
Summary of the online calculation (software format) for checking by the designer and an independent checker. Final sign-off remains the responsibility of the chartered or registered engineer.
Desktop edition: calculation reports and cross-module quantity reconciliation
1. Calculation reports: with a licence, the desktop edition writes Word (.docx) and Excel (.xlsx) calculation reports and DXF drawings without the trial watermark, listing the inputs, the equations used and the results; in trial mode the step-by-step detail is hidden. For this calculator alone, licensed users can also sign in on the calculator above and formally export a single-tool Word report (with a verification code) and DXF drawing. The Pro plan (all modules) is US$990 per year; see Pricing for monthly, perpetual and team plans.
2. Cross-module reconciliation: desktop project runs carry the design peak flow into downstream channel, culvert and bridge hydraulics; terrain cut/fill into the earthwork balance, cost and carbon tables; structural concrete, formwork and rebar take-off into the cost and carbon tables; slope and excavation safety-factor thresholds into construction monitoring trigger levels.
3. Independent checking engineers, authority reviewers and academics can request a complimentary review or teaching licence (link below).
1. Governing Equations & SI Nomenclature
The equations the calculation core applies are summarised below for independent checking.
The equations below summarise the method that the calculation core applies on this page. The design basis it reports is: Manning Uniform Flow Equation V = (1/n)·R^(2/3)·S^(1/2) (SI / Chow, 1959). The worked example further down lists the core's own calculation steps for the standard example.
2. Worked Standard Example (Computed by the Calculation Core)
The worked example below was computed by the calculation core when this page was built; entering the same inputs above reproduces it.
Design Scenario — Concrete-Lined Trapezoidal Drain (b = 1.0 m, 1V:1H, y = 0.60 m, S = 0.5%): Compute the discharge, velocity and Froude number of a trapezoidal drain with bottom width 1.0 m, side slopes 1V:1H and Manning n = 0.015, laid at S = 0.005 m/m and flowing 0.60 m deep.
The inputs below were passed to the calculation core (WebAssembly) when this page was built; every step, result and check shown here is the core's own output. Basis reported by the core: Manning Uniform Flow Equation V = (1/n)·R^(2/3)·S^(1/2) (SI / Chow, 1959)
Inputs Passed to the Calculation Core
| Parameter | Value | Unit |
|---|---|---|
| Cross-Section Shape | Trapezoidal | — |
| Bottom Width b | 1 | m |
| Side Slope z | 1 | — |
| Manning n | 0.015 | — |
| Longitudinal Slope S | 0.005 | m/m |
| Flow Depth y | 0.6 | m |
Calculation Steps (calculation core output)
[HyGeoWorks online preview - not for PE sealing or submittal]
- Section: Trapezoidal b = 1.000 m, side slope 1:1; n = 0.015, S = 0.005, depth y = 0.6 m
- A = (b + z·y)·y = (1.0000 + 1×0.6000)×0.6000 = 0.96000 m²
- P = b + 2y·√(1 + z²) = 1.0000 + 2×0.6000×√(1 + 1²) = 2.69706 m
- T = b + 2z·y = 2.20000 m
- R = A/P = 0.35594 m
- V = R^(2/3)·S^(1/2)/n = 0.35594^(2/3)×0.005^(1/2)/0.015 = 2.3676 m/s
- Q = A·V = 2.27293 m³/s
- Fr = V/√(g·A/T) = 2.3676/√(9.81×0.96000/2.20000) = 1.144 (Supercritical)
Computed Results (calculation core output)
| Output Parameter | Calculated Value | SI Unit |
|---|---|---|
| Flow Area A | 0.9600 | m² |
| Wetted Perimeter P | 2.6971 | m |
| Hydraulic Radius R | 0.3559 | m |
| Flow Velocity V | 2.368 | m/s |
| Discharge Q | 2.2729 | m³/s |
| Top Width T | 2.200 | m |
| Froude Number Fr | 1.144 | — |
3. Regional Design Options in This Edition: UK, EU, Singapore, Malaysia, Hong Kong & Australia
Symbols and units are SI unless stated otherwise.
- This calculator: the design basis is the one reported by the calculation core: Manning Uniform Flow Equation V = (1/n)·R^(2/3)·S^(1/2) (SI / Chow, 1959). The options listed below belong to the calculators named in each item.
- United Kingdom, Ireland & European Union: The retaining wall and slope stability calculators default to EN 1997-1:2004 Design Approach 1 (Combination 1 & Combination 2); the UK National Annex and 2nd-Gen EN 1997-1:2024 / EN 1997-3:2025 (MFA, and RFA for retaining walls) are selectable there, as are DA2 for retaining walls and DA3 for slopes. The retaining wall calculator lets γG, γQ and γφ' be overridden for a National Annex and designs metric H-bars (H10–H32) when concrete and steel strengths are entered.
- Singapore & Malaysia: The retaining wall calculator offers SS EN 1997-1:2010 with the Singapore National Annex, and the detention calculator offers a DID Malaysia MSMA 2nd Edition (2012) Equation 2.2 IDF rainfall mode besides directly entered design intensities.
- Hong Kong SAR: HyGeoWorks does not claim Hong Kong Buildings Department pre-accepted program status; the retaining wall calculator's HK GEO Geoguide 1 option shows the calculation core's steps and checks so that the result can be checked independently. With that option the calculation core applies the Geoguide 1 Table 6 and Table 7 partial factors at ULS and the §9.2.4 middle-third eccentricity check at SLS.
- Australia & New Zealand: No ARR 2019 IFD data is built in; design rainfall intensities for any AEP can be entered directly in the detention calculator. The HydroStudio desktop edition supports GDA2020 / MGA2020 zones 46–59 as well as WGS 84 / UTM zones.
4. Frequently Asked Questions
Common questions about this calculator are answered below. Final sign-off remains the responsibility of the chartered or registered engineer.
What does this calculator compute?
For the flow depth you enter, the calculation core computes flow area A, wetted perimeter P, hydraulic radius R, velocity V = (1/n)·R^(2/3)·S^(1/2), discharge Q = A·V, top width T and Froude number Fr = V/√(gA/T). It does not check permissible velocities or freeboard; for a permissible-velocity check, use the Normal & Critical Depth calculator with a channel lining selected.
Why does the Froude number matter?
Fr below 1 means subcritical flow, controlled from downstream; Fr above 1 means supercritical flow, controlled from upstream. Close to Fr = 1 the depth changes sharply with small changes in energy and the water surface tends to be wavy, so designers usually avoid channels that operate near critical flow.
Which Manning n should I use?
Manning n is an input; the calculator does not select it. Take it from the project specification, the pipe or lining manufacturer, or a recognised reference table such as Chow (1959), and consider ageing and sediment where they apply.
Can the online result be used for a submission?
The free online preview is not for sign-off or formal submission: the first line of every result marks it as a preview, and it has no Word report, DXF drawing or verification code. Licensed users can sign in on the page and formally export this calculator's Word report (with a verification code) and DXF drawing. You can also export a .toml project file and open it in the HydroStudio desktop edition (Windows 10/11, 64-bit); fields that the online tool does not cover are marked as placeholders and must be completed there before calculating. With a licence, whole-project calculation reports (Word .docx, Excel .xlsx with live formulas and .dxf drawings) can be exported online from the Project List or written by the desktop edition.
5. Explore All 30 Calculators (SI Edition; Design Basis Stated on Each Page)
Each calculator below states its own design basis on its page; several apply Taiwan regulations and say so.