Check Summary Preview (Software Format; Auto-Populated)
| Check item | Trial value | Status |
|---|---|---|
| Frontal Flow Ratio Eo | 0.7145 | Calculated value |
| Single-Inlet Efficiency E (Unclogged) | 0.7371 | Calculated value |
| Gutter Spread Width T | 1.997 m | Calculated value |
| Intercepted Flow Qi | 0.03538 m³/s | Calculated value |
Summary of the online calculation (software format) for checking by the designer and an independent checker. Final sign-off remains the responsibility of the chartered or registered engineer.
Desktop edition: calculation reports and cross-module quantity reconciliation
1. Calculation reports: with a licence, the desktop edition writes Word (.docx) and Excel (.xlsx) calculation reports and DXF drawings without the trial watermark, listing the inputs, the equations used and the results; in trial mode the step-by-step detail is hidden. For this calculator alone, licensed users can also sign in on the calculator above and formally export a single-tool Word report (with a verification code) and DXF drawing. The Pro plan (all modules) is US$990 per year; see Pricing for monthly, perpetual and team plans.
2. Cross-module reconciliation: desktop project runs carry the design peak flow into downstream channel, culvert and bridge hydraulics; terrain cut/fill into the earthwork balance, cost and carbon tables; structural concrete, formwork and rebar take-off into the cost and carbon tables; slope and excavation safety-factor thresholds into construction monitoring trigger levels.
3. Independent checking engineers, authority reviewers and academics can request a complimentary review or teaching licence (link below).
1. Governing Equations & SI Nomenclature
The equations the calculation core applies are summarised below for independent checking.
The equations below summarise the method that the calculation core applies on this page. The design basis it reports is: FHWA HEC-22 Urban Drainage Design Manual (3rd/4th Ed.) Ch. 4 & US EPA SWMM 5.2 Inlet Module. The worked example further down lists the core's own calculation steps for the standard example.
2. Worked Standard Example (Computed by the Calculation Core)
The worked example below was computed by the calculation core when this page was built; entering the same inputs above reproduces it.
Design Scenario — 600 × 600 mm P-50 Grate on a 2.0% Grade with 2.5% Cross Slope (Q = 0.06 m³/s): Check the gutter spread T, interception efficiency and bypass flow of a single 0.60 × 0.60 m P-50 parallel-bar grate on grade (n = 0.016, Sx = 0.025, SL = 0.02) with a 0.60 m gutter, 25 mm local depression and a clogging reduction factor of 0.2.
The inputs below were passed to the calculation core (WebAssembly) when this page was built; every step, result and check shown here is the core's own output. Basis reported by the core: FHWA HEC-22 Urban Drainage Design Manual (3rd/4th Ed.) Ch. 4 & US EPA SWMM 5.2 Inlet Module
Inputs Passed to the Calculation Core
| Parameter | Value | Unit |
|---|---|---|
| Inlet Location | On grade (by approach flow) | — |
| Inlet Configuration | Grate Inlet | — |
| Grate Type | P-50 parallel bar | — |
| Grate Length L | 0.6 | m |
| Grate Width Wg | 0.6 | m |
| Approach Flow Q | 0.06 | m³/s |
| Roadway Longitudinal Slope SL | 0.02 | m/m |
| Pavement Cross Slope SX | 0.025 | m/m |
| Pavement Manning n | 0.016 | — |
| Gutter Apron Width W | 0.6 | m |
| Local Depression a | 0.025 | m |
| Curb-to-Crown Distance | 3.5 | m |
| Clogging Reduction Factor | 0.2 | — |
| Number of Inlets in Series | 1 | — |
Calculation Steps (calculation core output)
[HyGeoWorks online preview - not for PE sealing or submittal]
- Inlet type: Grate (P-50 parallel bar 0.60×0.60 m), On-grade; cross slope Sx = 0.025, pavement n = 0.016, gutter width W = 0.6 m, gutter depression a = 0.025 m
- On-grade S_L = 0.02, approach flow Q = 0.06 m³/s → spread width T = 1.997 m (HEC-22 Eq. 4-2/4-4)
- Frontal flow ratio Eo = 0.7145; gutter velocity V = 1.046 m/s, splash-over velocity Vo = 2.466 m/s
- R_f = 1 − K_u(V − V_o) (V ≤ V_o -> 1.0) = 1.0000; R_s = 1/(1 + K_u·V^1.8/(S_x·L^2.3)) = 0.0792 (HEC-22 Eq. 4-18, 4-19, metric/US Ku constants per HEC-22)
- Single-inlet efficiency E = R_f·E_o + R_s·(1 − E_o) = 0.7371
- intercepted flow Qi = 0.03538 m³/s (1 inlets in series, clogging = 0.2); bypass flow Qb = 0.02462 m³/s
Computed Results (calculation core output)
| Output Parameter | Calculated Value | SI Unit |
|---|---|---|
| Frontal Flow Ratio Eo | 0.7145 | — |
| Single-Inlet Efficiency E (Unclogged) | 0.7371 | — |
| Gutter Spread Width T | 1.997 | m |
| Intercepted Flow Qi | 0.03538 | m³/s |
| Total Capture Efficiency E | 0.5897 | — |
| Bypass Carryover Flow Qb | 0.02462 | m³/s |
3. Regional Design Options in This Edition: UK, EU, Singapore, Malaysia, Hong Kong & Australia
Symbols and units are SI unless stated otherwise.
- This calculator: the design basis is the one reported by the calculation core: FHWA HEC-22 Urban Drainage Design Manual (3rd/4th Ed.) Ch. 4 & US EPA SWMM 5.2 Inlet Module. The options listed below belong to the calculators named in each item.
- United Kingdom, Ireland & European Union: The retaining wall and slope stability calculators default to EN 1997-1:2004 Design Approach 1 (Combination 1 & Combination 2); the UK National Annex and 2nd-Gen EN 1997-1:2024 / EN 1997-3:2025 (MFA, and RFA for retaining walls) are selectable there, as are DA2 for retaining walls and DA3 for slopes. The retaining wall calculator lets γG, γQ and γφ' be overridden for a National Annex and designs metric H-bars (H10–H32) when concrete and steel strengths are entered.
- Singapore & Malaysia: The retaining wall calculator offers SS EN 1997-1:2010 with the Singapore National Annex, and the detention calculator offers a DID Malaysia MSMA 2nd Edition (2012) Equation 2.2 IDF rainfall mode besides directly entered design intensities.
- Hong Kong SAR: HyGeoWorks does not claim Hong Kong Buildings Department pre-accepted program status; the retaining wall calculator's HK GEO Geoguide 1 option shows the calculation core's steps and checks so that the result can be checked independently. With that option the calculation core applies the Geoguide 1 Table 6 and Table 7 partial factors at ULS and the §9.2.4 middle-third eccentricity check at SLS.
- Australia & New Zealand: No ARR 2019 IFD data is built in; design rainfall intensities for any AEP can be entered directly in the detention calculator. The HydroStudio desktop edition supports GDA2020 / MGA2020 zones 46–59 as well as WGS 84 / UTM zones.
4. Frequently Asked Questions
Common questions about this calculator are answered below. Final sign-off remains the responsibility of the chartered or registered engineer.
What limits the allowable spread?
The calculator reports the spread T; it does not apply a spread limit. Allowable spread depends on the road class, speed and design storm and is set by the highway or drainage authority, so compare T with the value your authority requires.
Why does an inlet on grade let some flow bypass?
Flow outside the grate width enters only partly (side-flow capture Rs), and fast flow can splash over the grate (frontal capture Rf). Capturing all of the flow would need a very long grate, so on-grade inlets usually pass some flow to the next inlet downstream; the last inlet at a sag must take the remaining flow.
How is clogging treated?
The clogging reduction factor you enter reduces the interception of the unclogged inlet: Qi = (1 − clogging)·E·Q. Choose the factor from your authority's guidance for the inlet type and location.
How are inlets handled in the HydroStudio desktop edition?
The HydroStudio desktop edition includes a 1D drainage network coupled with a 2D shallow-water surface model (dual drainage), in which inlets exchange flow with the surface grid and manholes can surcharge onto the surface.
5. Explore All 30 Calculators (SI Edition; Design Basis Stated on Each Page)
Each calculator below states its own design basis on its page; several apply Taiwan regulations and say so.