Check Summary Preview (Software Format; Auto-Populated)
| Check item | Trial value | Status |
|---|---|---|
| Liquefaction Factor of Safety FS_liq (NCEER / Youd 2001) | 1.014 ≥ 1.00 | OK |
Summary of the online calculation (software format) for checking by the designer and an independent checker. Final sign-off remains the responsibility of the chartered or registered engineer.
Desktop edition: calculation reports and cross-module quantity reconciliation
1. Calculation reports: with a licence, the desktop edition writes Word (.docx) and Excel (.xlsx) calculation reports and DXF drawings without the trial watermark, listing the inputs, the equations used and the results; in trial mode the step-by-step detail is hidden. For this calculator alone, licensed users can also sign in on the calculator above and formally export a single-tool Word report (with a verification code) and DXF drawing. The Pro plan (all modules) is US$990 per year; see Pricing for monthly, perpetual and team plans.
2. Cross-module reconciliation: desktop project runs carry the design peak flow into downstream channel, culvert and bridge hydraulics; terrain cut/fill into the earthwork balance, cost and carbon tables; structural concrete, formwork and rebar take-off into the cost and carbon tables; slope and excavation safety-factor thresholds into construction monitoring trigger levels.
3. Independent checking engineers, authority reviewers and academics can request a complimentary review or teaching licence (link below).
1. Governing Equations & SI Nomenclature
The equations the calculation core applies are summarised below for independent checking.
The equations below summarise the method that the calculation core applies on this page. The design basis it reports is: NCEER / Youd et al. (2001) Simplified SPT Liquefaction Procedure & EN 1998-5 Annex B. The worked example further down lists the core's own calculation steps for the standard example.
2. Worked Standard Example (Computed by the Calculation Core)
The worked example below was computed by the calculation core when this page was built; entering the same inputs above reproduces it.
Design Scenario — Silty Sand at z = 6.0 m Under Mw = 7.0, PGA = 0.25g: Assess liquefaction triggering at 6.0 m depth in silty sand (field SPT N = 12, hammer energy ratio 70%, fines content 15%, water table at 1.5 m, γt = 18 kN/m³, γsat = 19.5 kN/m³). The calculation core checks the NCEER factor of safety against FS_liq ≥ 1.00 and lists the JRA, AIJ and HBF values alongside for comparison.
The inputs below were passed to the calculation core (WebAssembly) when this page was built; every step, result and check shown here is the core's own output. Basis reported by the core: NCEER / Youd et al. (2001) Simplified SPT Liquefaction Procedure & EN 1998-5 Annex B
Inputs Passed to the Calculation Core
| Parameter | Value | Unit |
|---|---|---|
| Test Depth z | 6 | m |
| Field SPT N-value | 12 | — |
| SPT Hammer Energy Ratio ER (%) | 70 | % |
| Fines Content FC (%) | 15 | % |
| Groundwater Depth GWT | 1.5 | m |
| Moist Unit Weight γt | 18 | kN/m³ |
| Saturated Unit Weight γsat | 19.5 | kN/m³ |
| Peak Ground Accel. PGA / g | 0.25 | g |
| Earthquake Magnitude Mw | 7 | — |
| Reference Pressure Pa (overburden correction) | Pa = 100 kPa (≈ 1 atm) | — |
Calculation Steps (calculation core output)
[HyGeoWorks online preview - not for PE sealing or submittal]
- Total overburden stress σv0 = 18×1.5 + 19.5×4.50 = 114.75 kPa; Effective stress σ'v0 = 70.61 kPa
- NCEER (Youd et al., 2001): N60 = N·ER/60 = 14.00, CN = 1.190, (N1)60cs = 19.97, MSF = 1.193, CRR7.5×MSF = 0.2565, rd = 0.958, CSR = 0.65·(amax/g)·(σv0/σ'v0)·rd = 0.2529 → FS_liq = CRR / CSR = 1.014
Computed Results (calculation core output)
| Output Parameter | Calculated Value | SI Unit |
|---|---|---|
| FS_liq (NCEER / Youd 2001) | 1.014 | — |
| FS_liq (JRA Method) | 0.724 | — |
| FS_liq (AIJ Method) | 1.174 | — |
| FS_liq (HBF Method) | 0.973 | — |
Verification Checks (calculation core output)
| Verification Check | Computed Value | Criterion | Verdict | Basis |
|---|---|---|---|---|
| Liquefaction Factor of Safety FS_liq (NCEER / Youd 2001) | 1.014 | ≥ 1.00 | OK | Youd et al. (2001) JGGE & EN 1998-5 §4.1.4 |
Multi-Method Liquefaction Triggering Comparison (4 rows)
| Method | N60 / N72 | CN | (N1) | (N1)60cs / Na | MSF | CRR | rd | CSR | FS_liq |
|---|---|---|---|---|---|---|---|---|---|
| NCEER (Youd 2001) | 14.00 | 1.190 | 16.67 | 19.97 | 1.193 | 0.2565 | 0.958 | 0.2529 | 1.014 |
| JRA (Road Bridge Spec.) | 11.67 | - | 13.97 | 15.64 | - | 0.2676 | 0.910 | 0.3697 | 0.724 |
| AIJ (Arch. Inst. Japan) | 11.67 | 1.190 | 13.89 | 20.89 | - | 0.2605 | 0.910 | 0.2218 | 1.174 |
| HBF (Hyperbolic) | 14.00 | 1.190 | 16.67 | 19.28 | 1.132 | 0.2416 | 0.940 | 0.2483 | 0.973 |
Assumptions and Limits Stated by the Calculation Core
- NCEER & HBF use N60 energy normalization; AIJ & JRA use Japanese N72 practice.
3. Regional Design Options in This Edition: UK, EU, Singapore, Malaysia, Hong Kong & Australia
Symbols and units are SI unless stated otherwise.
- This calculator: the design basis is the one reported by the calculation core: NCEER / Youd et al. (2001) Simplified SPT Liquefaction Procedure & EN 1998-5 Annex B. The options listed below belong to the calculators named in each item.
- United Kingdom, Ireland & European Union: The retaining wall and slope stability calculators default to EN 1997-1:2004 Design Approach 1 (Combination 1 & Combination 2); the UK National Annex and 2nd-Gen EN 1997-1:2024 / EN 1997-3:2025 (MFA, and RFA for retaining walls) are selectable there, as are DA2 for retaining walls and DA3 for slopes. The retaining wall calculator lets γG, γQ and γφ' be overridden for a National Annex and designs metric H-bars (H10–H32) when concrete and steel strengths are entered.
- Singapore & Malaysia: The retaining wall calculator offers SS EN 1997-1:2010 with the Singapore National Annex, and the detention calculator offers a DID Malaysia MSMA 2nd Edition (2012) Equation 2.2 IDF rainfall mode besides directly entered design intensities.
- Hong Kong SAR: HyGeoWorks does not claim Hong Kong Buildings Department pre-accepted program status; the retaining wall calculator's HK GEO Geoguide 1 option shows the calculation core's steps and checks so that the result can be checked independently. With that option the calculation core applies the Geoguide 1 Table 6 and Table 7 partial factors at ULS and the §9.2.4 middle-third eccentricity check at SLS.
- Australia & New Zealand: No ARR 2019 IFD data is built in; design rainfall intensities for any AEP can be entered directly in the detention calculator. The HydroStudio desktop edition supports GDA2020 / MGA2020 zones 46–59 as well as WGS 84 / UTM zones.
4. Frequently Asked Questions
Common questions about this calculator are answered below. Final sign-off remains the responsibility of the chartered or registered engineer.
Why does the SPT hammer energy ratio matter?
Blow counts are normalised to 60% energy: N60 = N·ER/60. For example, N = 12 measured with a hammer of 70% energy ratio gives N60 = 12 × 70/60 = 14. Using the raw blow count with an efficient hammer underestimates the liquefaction resistance.
Which factor of safety is checked?
The check row compares the NCEER factor of safety FS_liq = CRR/CSR with 1.00, as reported by the calculation core. EN 1998-5 or a National Annex may require a different factor; compare the reported FS_liq with the value that applies to your project.
Why are the JRA, AIJ and HBF results listed?
They show how sensitive the assessment is to the method. As the calculation core notes, the NCEER and HBF methods use N60 energy normalisation while the AIJ and JRA methods follow Japanese N72 practice. The reference pressure option for the overburden correction refers to Taiwan codes (Taiwan Foundation Code or Taiwan Seismic Code).
How is a whole borehole profile assessed?
This page evaluates a single test depth. The HydroStudio desktop edition evaluates an SPT borehole profile and integrates the liquefaction potential index PL = ∫₀²⁰ F(z)·(10 − 0.5z) dz with F = 1 − FL where FL < 1.
5. Explore All 30 Calculators (SI Edition; Design Basis Stated on Each Page)
Each calculator below states its own design basis on its page; several apply Taiwan regulations and say so.