Check Summary Preview (Software Format; Auto-Populated)
| Check item | Trial value | Status |
|---|---|---|
| Drop height | 1.50 m ≤ 3 m (higher drops require a project-specific design) | OK |
Summary of the online calculation (software format) for checking by the designer and an independent checker. Final sign-off remains the responsibility of the chartered or registered engineer.
Desktop edition: calculation reports and cross-module quantity reconciliation
1. Calculation reports: with a licence, the desktop edition writes Word (.docx) and Excel (.xlsx) calculation reports and DXF drawings without the trial watermark, listing the inputs, the equations used and the results; in trial mode the step-by-step detail is hidden. For this calculator alone, licensed users can also sign in on the calculator above and formally export a single-tool Word report (with a verification code) and DXF drawing. The Pro plan (all modules) is US$990 per year; see Pricing for monthly, perpetual and team plans.
2. Cross-module reconciliation: desktop project runs carry the design peak flow into downstream channel, culvert and bridge hydraulics; terrain cut/fill into the earthwork balance, cost and carbon tables; structural concrete, formwork and rebar take-off into the cost and carbon tables; slope and excavation safety-factor thresholds into construction monitoring trigger levels.
3. Independent checking engineers, authority reviewers and academics can request a complimentary review or teaching licence (link below).
1. Governing Equations & SI Nomenclature
The equations the calculation core applies are summarised below for independent checking.
The equations below summarise the method that the calculation core applies on this page. The design basis it reports is: Taiwan Soil and Water Conservation Handbook (2017) §2.20 Drop Structures (apron and stilling basin length, sills, wingwalls, RC thickness). The worked example further down lists the core's own calculation steps for the standard example.
2. Worked Standard Example (Computed by the Calculation Core)
The worked example below was computed by the calculation core when this page was built; entering the same inputs above reproduces it.
Design Scenario — 1.50 m Vertical Drop with Stilling Basin (Q = 1.50 m³/s, b = 1.20 m): Proportion the stilling basin length, end sill, longitudinal sill, baffle-sill position, wingwalls and RC slab details of a 1.50 m vertical drop (stilling-basin type) with a 1.20 m crest carrying 1.50 m³/s, with 0.50 m upstream and tailwater depths and 1.50 m channel widths upstream and downstream.
The inputs below were passed to the calculation core (WebAssembly) when this page was built; every step, result and check shown here is the core's own output. Basis reported by the core: Taiwan Soil and Water Conservation Handbook (2017) §2.20 Drop Structures (apron and stilling basin length, sills, wingwalls, RC thickness)
Inputs Passed to the Calculation Core
| Parameter | Value | Unit |
|---|---|---|
| Drop Structure Type | Types B, D, E (stilling basin) | — |
| Design Discharge Q | 1.5 | m³/s |
| Drop Crest Width b | 1.2 | m |
| Drop Height Hd | 1.5 | m |
| Upstream Depth h1 | 0.5 | m |
| Tailwater Depth h2 | 0.5 | m |
| Upstream Channel Width Wu | 1.5 | m |
| Downstream Channel Width Wd | 1.5 | m |
| Brick Masonry | No | — |
| Apron / Stilling Basin Length Provided | (blank) | m |
Calculation Steps (calculation core output)
[HyGeoWorks online preview - not for PE sealing or submittal]
- dc = (Q²/(b²·g))^(1/3) = (1.5²/(1.2²×9.8))^(1/3) = 0.5422 m
- Stilling basin length L = √(H·dc)·(2.5 + 1.1·dc/H + 0.7·(dc/H)³) = √(1.5×0.5422)×(2.5 + 1.1×0.3615 + 0.7×0.3615³) = 2.643 m
- End sill height H' = dc/2 = 0.271 m; longitudinal sill height = ¾H' = 0.203 m
- Cx (Wd/b = 1.250 interpolated) = 0.1800; baffle sill position X = Cx·b + 0.45 = 0.666 m
- Min. length 0.8L = 2.115 m (where terrain-constrained)
- Upstream wingwall B = (Wu − b)/2 + h1 + 0.2 = 0.850 m; Downstream wingwall A = (Wd − b − 0.4)/2 + h + 0.2 = 0.650 m (each >= 1 m)
- RC slab: thickness >= 15 cm, D13@25 cm (H ≤ 2 m)
Computed Results (calculation core output)
| Output Parameter | Calculated Value | SI Unit |
|---|---|---|
| Critical Depth dc | 0.5422 | m |
| Stilling Basin Length L | 2.643 | m |
| Minimum Terrain-Constrained Length 0.8L | 2.115 | m |
| End Sill Height H' | 0.271 | m |
| Longitudinal Sill Height | 0.203 | m |
| Baffle Sill Distance X | 0.666 | m |
| Upstream Wingwall Width B | 1.000 | m |
| Downstream Wingwall Width A | 1.000 | m |
| Min. RC Slab Thickness | 15 | cm |
| Max. Rebar Spacing | 25 | cm |
Verification Checks (calculation core output)
| Verification Check | Computed Value | Criterion | Verdict | Basis |
|---|---|---|---|---|
| Drop height | 1.50 m | ≤ 3 m (higher drops require a project-specific design) | OK | Taiwan Soil and Water Conservation Handbook (2017) §2.20 Drop Structures |
Assumptions and Limits Stated by the Calculation Core
- dc/H = 0.361: SCS NEH-11 recommends h/F < 0.5 (dc/H ≤ 1/3)
- Drop crest width b = 1.20 m is less than 3dc = 1.63 m (SCS NEH-11 recommends L/h ≥ 2)
- Stilling basin length taken as the computed value L = 2.64 m (where constrained by terrain it may be shortened to 2.11 m)
- Upstream wingwall B by formula = 0.85 m, less than 1 m; 1 m is used
- Downstream wingwall A by formula = 0.65 m, less than 1 m; 1 m is used
3. Regional Design Options in This Edition: UK, EU, Singapore, Malaysia, Hong Kong & Australia
Symbols and units are SI unless stated otherwise.
- This calculator: the design basis is the one reported by the calculation core: Taiwan Soil and Water Conservation Handbook (2017) §2.20 Drop Structures (apron and stilling basin length, sills, wingwalls, RC thickness). The options listed below belong to the calculators named in each item.
- United Kingdom, Ireland & European Union: The retaining wall and slope stability calculators default to EN 1997-1:2004 Design Approach 1 (Combination 1 & Combination 2); the UK National Annex and 2nd-Gen EN 1997-1:2024 / EN 1997-3:2025 (MFA, and RFA for retaining walls) are selectable there, as are DA2 for retaining walls and DA3 for slopes. The retaining wall calculator lets γG, γQ and γφ' be overridden for a National Annex and designs metric H-bars (H10–H32) when concrete and steel strengths are entered.
- Singapore & Malaysia: The retaining wall calculator offers SS EN 1997-1:2010 with the Singapore National Annex, and the detention calculator offers a DID Malaysia MSMA 2nd Edition (2012) Equation 2.2 IDF rainfall mode besides directly entered design intensities.
- Hong Kong SAR: HyGeoWorks does not claim Hong Kong Buildings Department pre-accepted program status; the retaining wall calculator's HK GEO Geoguide 1 option shows the calculation core's steps and checks so that the result can be checked independently. With that option the calculation core applies the Geoguide 1 Table 6 and Table 7 partial factors at ULS and the §9.2.4 middle-third eccentricity check at SLS.
- Australia & New Zealand: No ARR 2019 IFD data is built in; design rainfall intensities for any AEP can be entered directly in the detention calculator. The HydroStudio desktop edition supports GDA2020 / MGA2020 zones 46–59 as well as WGS 84 / UTM zones.
4. Frequently Asked Questions
Common questions about this calculator are answered below. Final sign-off remains the responsibility of the chartered or registered engineer.
When should a stilling basin (Types B, D, E) be chosen over a straight apron (Type A)?
A plain apron relies on enough tailwater to keep the falling jet from sweeping onto the downstream bed. Where the tailwater is low or uncertain, a stilling basin with an end sill holds a water cushion that dissipates the energy of the nappe.
Where do the RC slab thickness and bar spacing come from?
The calculation core reports a minimum RC slab thickness and maximum bar spacing from Taiwan Soil and Water Conservation Handbook §2.20, shown in the results. These are handbook minimums; structural design of the slab and walls under your concrete code is not part of this calculator.
What if the drop is higher than 3 m?
The core checks the drop height against 3 m and notes that higher drops require a project-specific design. Either split the fall into several smaller drops (see the Stepped Chute calculator, /en/tools/stepped-chute/) or design a chute with a stilling basin; the HydroStudio desktop edition includes chute design with USBR Type II, III and IV and SAF basins.
What do the core's notes on dc/H and crest width mean?
The core compares the ratio dc/H and the crest width with the recommendations of SCS NEH-11 and reports them as notes. They flag proportions outside the recommended range; they are not pass/fail checks.
5. Explore All 30 Calculators (SI Edition; Design Basis Stated on Each Page)