Check Summary Preview (Software Format; Auto-Populated)
| Check item | Trial value | Status |
|---|---|---|
| MH1→MH2 minimum design velocity | 2.81 m/s ≥ 0.80 m/s | OK |
| MH1→MH2 maximum design velocity | 2.81 m/s ≤ 3.00 m/s | OK |
| MH1→MH2 capacity (full-flow discharge ≥ design discharge) | 2.14 m³/s ≥ 1.20 m³/s | OK |
| MH1→MH2 minimum pipe diameter | 1.00 m ≥ 0.80 m | OK |
| MH1→MH2 minimum cover depth | 1.00 m ≥ 0.50 m | OK |
| MH1→MH2 manhole spacing | 40.00 m ≤ 150.00 m | OK |
Summary of the online calculation (software format) for checking by the designer and an independent checker. Final sign-off remains the responsibility of the chartered or registered engineer.
Desktop edition: calculation reports and cross-module quantity reconciliation
1. Calculation reports: with a licence, the desktop edition writes Word (.docx) and Excel (.xlsx) calculation reports and DXF drawings without the trial watermark, listing the inputs, the equations used and the results; in trial mode the step-by-step detail is hidden. For this calculator alone, licensed users can also sign in on the calculator above and formally export a single-tool Word report (with a verification code) and DXF drawing. The Pro plan (all modules) is US$990 per year; see Pricing for monthly, perpetual and team plans.
2. Cross-module reconciliation: desktop project runs carry the design peak flow into downstream channel, culvert and bridge hydraulics; terrain cut/fill into the earthwork balance, cost and carbon tables; structural concrete, formwork and rebar take-off into the cost and carbon tables; slope and excavation safety-factor thresholds into construction monitoring trigger levels.
3. Independent checking engineers, authority reviewers and academics can request a complimentary review or teaching licence (link below).
1. Worked Standard Example (Computed by the Calculation Core)
The worked example below was computed by the calculation core when this page was built; entering the same inputs above reproduces it.
Design Scenario — Standard example (calculation core defaults): The standard example uses the default inputs of the calculation core. Every number below was produced by the core when this page was built; nothing on this page is computed by hand.
The inputs below were passed to the calculation core (WebAssembly) when this page was built; every step, result and check shown here is the core's own output. Basis reported by the core: Taiwan Sewerage Engineering Facility Standards (amended 2025-11-04) Arts. 3-8; Manning flow and hydraulic grade line by the design-table method
Inputs Passed to the Calculation Core
| Parameter | Value | Unit |
|---|---|---|
| Conduit Section | Circular pipe (RCP) | — |
| Pipe Inside Diameter D | 1 | m |
| Conduit Wall Thickness | 0.1 | m |
| Reinforced Concrete Pipe | Yes | — |
| Reach Length L | 40 | m |
| Ground Level at Upstream Manhole | 102.5 | m |
| Ground Level at Downstream Manhole | 102.1 | m |
| Upstream Invert Level | 100.32 | m |
| Downstream Invert Level | 100 | m |
| Design Discharge Q | 1.2 | cms |
| Manning Roughness n | 0.013 | — |
| Head Loss Coefficient at Upstream Manhole K | 0.5 | — |
| Downstream Receiving Water Level | (blank) | m |
| Check vertical clearance to a crossing utility | Yes | — |
| Station of Crossing Utility | 20 | m |
| Crossing Utility Top Level (outside) | 101.95 | m |
| Crossing Utility Bottom Level (outside) | 101.65 | m |
| Required Minimum Vertical Clearance | 0.3 | m |
Calculation Steps (calculation core output)
[HyGeoWorks online preview - not for PE sealing or submittal]
- Slope S = 0.0080; full-flow capacity Qf = 2.144 m³/s; design depth 0.53 m, velocity V = 2.81 m/s
- Upstream manhole HGL 101.06 m, ground level 102.50 m → freeboard 1.44 m; cover over crown: upstream 1.08 m, downstream 1.00 m
Computed Results (calculation core output)
| Output Parameter | Calculated Value | SI Unit |
|---|---|---|
| Design velocity V | 2.81 | m/s |
| Design depth | 0.53 | m |
| Full-flow capacity Qf | 2.144 | m³/s |
| Upstream manhole HGL | 101.06 | m |
| Upstream manhole freeboard (ground − HGL) | 1.44 | m |
| Minimum cover over crown | 1.00 | m |
| Vertical clearance to crossing utility | 0.39 | m |
Verification Checks (calculation core output)
| Verification Check | Computed Value | Criterion | Verdict | Basis |
|---|---|---|---|---|
| MH1→MH2 minimum design velocity | 2.81 m/s | ≥ 0.80 m/s | OK | Taiwan Sewerage Engineering Facility Standards (amended 2025-11-04) Art. 3, item 3 |
| MH1→MH2 maximum design velocity | 2.81 m/s | ≤ 3.00 m/s | OK | Taiwan Sewerage Engineering Facility Standards (amended 2025-11-04) Art. 3, item 3 |
| MH1→MH2 capacity (full-flow discharge ≥ design discharge) | 2.14 m³/s | ≥ 1.20 m³/s | OK | Taiwan Sewerage Engineering Facility Standards (amended 2025-11-04) Art. 3 (Manning equation) |
| MH1→MH2 minimum pipe diameter | 1.00 m | ≥ 0.80 m | OK | Taiwan Sewerage Engineering Facility Standards (amended 2025-11-04) Art. 4 |
| MH1→MH2 minimum cover depth | 1.00 m | ≥ 0.50 m | OK | Taiwan Sewerage Engineering Facility Standards (amended 2025-11-04) Art. 5, item 2 (reinforced concrete pipe 50 cm; strengthen if less) |
| MH1→MH2 manhole spacing | 40.00 m | ≤ 150.00 m | OK | Taiwan Sewerage Engineering Facility Standards (amended 2025-11-04) Art. 8, item 2 |
| Manhole MH1 hydraulic grade line not above ground level | 101.06 m | ≤ 102.50 m | OK | A hydraulic grade line above ground level means surcharge at the manhole |
| Manhole MH2 hydraulic grade line not above ground level | 100.53 m | ≤ 102.10 m | OK | A hydraulic grade line above ground level means surcharge at the manhole |
| Existing utility U1 vertical clearance | 0.39 m | ≥ 0.30 m | OK | The required clearance is an input (per the rules of the utility authority) |
Hydraulic grade line at manholes (2 rows)
| Manhole | Station (m) | Ground level (m) | HGL (m) | Freeboard (m) |
|---|---|---|---|---|
| MH1 | 0.0 | 102.50 | 101.06 | 1.44 |
| MH2 | 40.0 | 102.10 | 100.53 | 1.57 |
Assumptions and Limits Stated by the Calculation Core
- No downstream boundary water level given: the normal-depth level of the last reach is used (free outfall); enter the receiving water level when it is higher, to reflect backwater
- The minimum clearance to existing utilities is an input: Taiwan Sewerage Engineering Facility Standards (amended 2025-11-04) Art. 5 only requires prior joint survey and coordination with the relevant authorities when a sewer crosses existing public facilities and sets no numerical value; no clearance rule is built in
- The hydraulic grade line uses the design-table method (normal depth for free-surface reaches, full-pipe friction loss for pressurized reaches) without gradually varied flow computation; the design discharge of each reach is an input
2. Frequently Asked Questions
Common questions about this calculator are answered below. Final sign-off remains the responsibility of the chartered or registered engineer.
Which design basis does this calculator apply?
Taiwan Sewerage Engineering Facility Standards (amended 2025-11-04) Arts. 3-8; Manning flow and hydraulic grade line by the design-table method. Velocity, size, cover and manhole-spacing limits are those of the Taiwan sewer standard named in the basis line; check the requirements of your own authority separately.
What assumptions and limits does the calculation core state for this tool?
No downstream boundary water level given: the normal-depth level of the last reach is used (free outfall); enter the receiving water level when it is higher, to reflect backwater. The minimum clearance to existing utilities is an input: Taiwan Sewerage Engineering Facility Standards (amended 2025-11-04) Art. 5 only requires prior joint survey and coordination with the relevant authorities when a sewer crosses existing public facilities and sets no numerical value; no clearance rule is built in. The hydraulic grade line uses the design-table method (normal depth for free-surface reaches, full-pipe friction loss for pressurized reaches) without gradually varied flow computation; the design discharge of each reach is an input.
Where is the calculation performed, and can the result be sealed or submitted?
The calculation runs in your browser, in the same WebAssembly calculation core this page loads. The result is an online preview: its first line reads "[HyGeoWorks online preview - not for PE sealing or submittal]".
Can I recalculate without a network connection?
Yes. "Download the offline workbench" on this page saves one HTML file that contains the workbench and the same calculation core; opened from disk it recalculates without a network connection.
3. Explore All 30 Calculators (SI Edition; Design Basis Stated on Each Page)