Storm Sewer Longitudinal Profile, HGL & Utility Clearance Check

Slope, flow velocity and full-flow capacity of a storm sewer reach, hydraulic grade line (HGL) at the manholes with an optional downstream water level, minimum cover, manhole spacing, and vertical clearance to a crossing utility.

Design basis and scope notes for this page ▾
Taiwan Sewerage Engineering Facility Standards (amended 2025-11-04) Arts. 3-8; Manning flow and hydraulic grade line by the design-table method
Design basis as reported by the calculation core: Taiwan Sewerage Engineering Facility Standards (amended 2025-11-04) Arts. 3-8; Manning flow and hydraulic grade line by the design-table method
Velocity, size, cover and manhole-spacing limits are those of the Taiwan sewer standard named in the basis line; check the requirements of your own authority separately.

Recalculates in your browser as you edit inputs; Free sample Word report and DXF for this calculator; With a licence: formal Word and DXF export, plus online project reports from the Project List.

Free samples and pricing
A public sample produced by the production service from this page's standard example and sealed with a verification code: open it in Word or AutoCAD and check it on the Verify page. Not for formal submission.
Single-export pass: US$19 for one calculator, 3 formal exports in total within 24 hours of the first; full credit toward an upgrade within 30 days, full refund before the first export
Single-export passes (one calculator, 3 exports within 24 hours), 30-day passes, annual plans and perpetual licences; printable quotes for purchase orders.
Formal export and the Project List are on the workbench toolbar above:
Licensed users can formally export this calculator's Word report (with a verification code and server time witness) and AutoCAD DXF drawing, or add several calculators to the free Project List and export a multi-chapter project report online, with nothing to install on a Mac. Projects with DEM terrain or GIS files can run in the heavy cloud computation or in the HydroStudio desktop edition.
The summary lists the basis, key results and check verdicts; its first line marks it as an online preview, not for formal submission.
Download the offline workbench (single HTML file, 39 tools)
No install and no email required. It contains the same calculation core as this site; results are also a preview, not for formal submission.

Check Summary Preview (Software Format; Auto-Populated)

Storm Sewer Longitudinal Profile, HGL & Utility Clearance Check: check summary (software format)
Calculation basis: Taiwan Sewerage Engineering Facility Standards (amended 2025-11-04) Arts. 3-8; Manning flow and hydraulic grade line by the design-table method
Check item Trial value Status
MH1→MH2 minimum design velocity2.81 m/s ≥ 0.80 m/sOK
MH1→MH2 maximum design velocity2.81 m/s ≤ 3.00 m/sOK
MH1→MH2 capacity (full-flow discharge ≥ design discharge)2.14 m³/s ≥ 1.20 m³/sOK
MH1→MH2 minimum pipe diameter1.00 m ≥ 0.80 mOK
MH1→MH2 minimum cover depth1.00 m ≥ 0.50 mOK
MH1→MH2 manhole spacing40.00 m ≤ 150.00 mOK

Summary of the online calculation (software format) for checking by the designer and an independent checker. Final sign-off remains the responsibility of the chartered or registered engineer.

Desktop edition: calculation reports and cross-module quantity reconciliation

1. Calculation reports: with a licence, the desktop edition writes Word (.docx) and Excel (.xlsx) calculation reports and DXF drawings without the trial watermark, listing the inputs, the equations used and the results; in trial mode the step-by-step detail is hidden. For this calculator alone, licensed users can also sign in on the calculator above and formally export a single-tool Word report (with a verification code) and DXF drawing. The Pro plan (all modules) is US$990 per year; see Pricing for monthly, perpetual and team plans.
2. Cross-module reconciliation: desktop project runs carry the design peak flow into downstream channel, culvert and bridge hydraulics; terrain cut/fill into the earthwork balance, cost and carbon tables; structural concrete, formwork and rebar take-off into the cost and carbon tables; slope and excavation safety-factor thresholds into construction monitoring trigger levels.
3. Independent checking engineers, authority reviewers and academics can request a complimentary review or teaching licence (link below).

Desktop pricing (Pro US$990/yr) Download the desktop trial Complimentary licence for checkers, reviewers and academics
Scope and responsibility: This page is a single-calculator trial run; cross-module quantity reconciliation is done in desktop project runs. Problems outside this calculator's scope (see the FAQ) need an appropriate analysis method. Final sign-off remains the responsibility of the chartered or registered engineer.

1. Worked Standard Example (Computed by the Calculation Core)

The worked example below was computed by the calculation core when this page was built; entering the same inputs above reproduces it.

Design Scenario — Standard example (calculation core defaults): The standard example uses the default inputs of the calculation core. Every number below was produced by the core when this page was built; nothing on this page is computed by hand.

The inputs below were passed to the calculation core (WebAssembly) when this page was built; every step, result and check shown here is the core's own output. Basis reported by the core: Taiwan Sewerage Engineering Facility Standards (amended 2025-11-04) Arts. 3-8; Manning flow and hydraulic grade line by the design-table method

Inputs Passed to the Calculation Core

ParameterValueUnit
Conduit SectionCircular pipe (RCP)—
Pipe Inside Diameter D1m
Conduit Wall Thickness0.1m
Reinforced Concrete PipeYes—
Reach Length L40m
Ground Level at Upstream Manhole102.5m
Ground Level at Downstream Manhole102.1m
Upstream Invert Level100.32m
Downstream Invert Level100m
Design Discharge Q1.2cms
Manning Roughness n0.013—
Head Loss Coefficient at Upstream Manhole K0.5—
Downstream Receiving Water Level(blank)m
Check vertical clearance to a crossing utilityYes—
Station of Crossing Utility20m
Crossing Utility Top Level (outside)101.95m
Crossing Utility Bottom Level (outside)101.65m
Required Minimum Vertical Clearance0.3m

Calculation Steps (calculation core output)

[HyGeoWorks online preview - not for PE sealing or submittal]

  1. Slope S = 0.0080; full-flow capacity Qf = 2.144 m³/s; design depth 0.53 m, velocity V = 2.81 m/s
  2. Upstream manhole HGL 101.06 m, ground level 102.50 m → freeboard 1.44 m; cover over crown: upstream 1.08 m, downstream 1.00 m

Computed Results (calculation core output)

Output ParameterCalculated ValueSI Unit
Design velocity V2.81m/s
Design depth0.53m
Full-flow capacity Qf2.144m³/s
Upstream manhole HGL101.06m
Upstream manhole freeboard (ground − HGL)1.44m
Minimum cover over crown1.00m
Vertical clearance to crossing utility0.39m

Verification Checks (calculation core output)

Verification CheckComputed ValueCriterionVerdictBasis
MH1→MH2 minimum design velocity2.81 m/s≥ 0.80 m/sOKTaiwan Sewerage Engineering Facility Standards (amended 2025-11-04) Art. 3, item 3
MH1→MH2 maximum design velocity2.81 m/s≤ 3.00 m/sOKTaiwan Sewerage Engineering Facility Standards (amended 2025-11-04) Art. 3, item 3
MH1→MH2 capacity (full-flow discharge ≥ design discharge)2.14 m³/s≥ 1.20 m³/sOKTaiwan Sewerage Engineering Facility Standards (amended 2025-11-04) Art. 3 (Manning equation)
MH1→MH2 minimum pipe diameter1.00 m≥ 0.80 mOKTaiwan Sewerage Engineering Facility Standards (amended 2025-11-04) Art. 4
MH1→MH2 minimum cover depth1.00 m≥ 0.50 mOKTaiwan Sewerage Engineering Facility Standards (amended 2025-11-04) Art. 5, item 2 (reinforced concrete pipe 50 cm; strengthen if less)
MH1→MH2 manhole spacing40.00 m≤ 150.00 mOKTaiwan Sewerage Engineering Facility Standards (amended 2025-11-04) Art. 8, item 2
Manhole MH1 hydraulic grade line not above ground level101.06 m≤ 102.50 mOKA hydraulic grade line above ground level means surcharge at the manhole
Manhole MH2 hydraulic grade line not above ground level100.53 m≤ 102.10 mOKA hydraulic grade line above ground level means surcharge at the manhole
Existing utility U1 vertical clearance0.39 m≥ 0.30 mOKThe required clearance is an input (per the rules of the utility authority)
Hydraulic grade line at manholes (2 rows)
ManholeStation (m)Ground level (m)HGL (m)Freeboard (m)
MH10.0102.50101.061.44
MH240.0102.10100.531.57

Assumptions and Limits Stated by the Calculation Core

2. Frequently Asked Questions

Common questions about this calculator are answered below. Final sign-off remains the responsibility of the chartered or registered engineer.

Which design basis does this calculator apply?

Taiwan Sewerage Engineering Facility Standards (amended 2025-11-04) Arts. 3-8; Manning flow and hydraulic grade line by the design-table method. Velocity, size, cover and manhole-spacing limits are those of the Taiwan sewer standard named in the basis line; check the requirements of your own authority separately.

What assumptions and limits does the calculation core state for this tool?

No downstream boundary water level given: the normal-depth level of the last reach is used (free outfall); enter the receiving water level when it is higher, to reflect backwater. The minimum clearance to existing utilities is an input: Taiwan Sewerage Engineering Facility Standards (amended 2025-11-04) Art. 5 only requires prior joint survey and coordination with the relevant authorities when a sewer crosses existing public facilities and sets no numerical value; no clearance rule is built in. The hydraulic grade line uses the design-table method (normal depth for free-surface reaches, full-pipe friction loss for pressurized reaches) without gradually varied flow computation; the design discharge of each reach is an input.

Where is the calculation performed, and can the result be sealed or submitted?

The calculation runs in your browser, in the same WebAssembly calculation core this page loads. The result is an online preview: its first line reads "[HyGeoWorks online preview - not for PE sealing or submittal]".

Can I recalculate without a network connection?

Yes. "Download the offline workbench" on this page saves one HTML file that contains the workbench and the same calculation core; opened from disk it recalculates without a network connection.

From the Online Preview to the HydroStudio Desktop Edition

The free preview has no Word report, DXF drawing or verification code. Licensed users can sign in on the calculator and formally export a single-tool Word report (with a verification code) and DXF drawing, or combine several calculators in the Project List and export a multi-chapter project report online; projects with terrain or GIS files can run in the heavy cloud computation, and interactive 2D models and large simulations use the desktop edition. Export a .toml project file from the calculator and open it in the HydroStudio desktop edition (Windows 10/11, 64-bit); fields that the online tool does not cover are marked as placeholders and must be completed there before calculating. With a licence, the desktop edition writes Word (.docx) calculation reports, Excel (.xlsx) workbooks with live formulas and .dxf drawings without the trial watermark, and also includes 2D shallow-water flood modelling (Godunov finite volume) and 2D finite-element variably saturated seepage.

✓ USD checkout via Stripe  ·  ✓ Printable USD quotation (print or save as PDF)  ·  ✓ Ed25519-signed licence with a 14-day offline lease
Desktop Licence Pricing (USD)
$990 USD / year (Pro, all modules)
Also available: Pro monthly at $119/month, a single-discipline annual licence at $590/yr and a 30-day single-discipline pass at $79. Purchasing approval follows your organisation's own rules.
View USD Pricing & Printable Quotation →

3. Explore All 30 Calculators (SI Edition; Design Basis Stated on Each Page)

Each calculator below states its own design basis on its page; several apply Taiwan regulations and say so.

Open-Channel & Pipe Hydraulics
Manning Open-Channel & Circular Pipe Flow Calculator
Open calculator
Open-Channel & Pipe Hydraulics
Manning Normal Depth (yn) & Critical Depth (yc) Calculator
Open calculator
Open-Channel & Pipe Hydraulics
Pipe Diameter & Channel Bottom Width Sizing Calculator
Open calculator
Stormwater Detention & Roadway Drainage
Detention Outlet Orifice & Rectangular Weir Sizing Calculator
Open calculator
Stormwater Detention & Roadway Drainage
Gutter Flow Spread & Kerb / Grate Inlet Interception Calculator
Open calculator
Open-Channel & Pipe Hydraulics
Box & Circular Pipe Culvert Inlet / Outlet Control Calculator
Open calculator
Energy Dissipation & Scour Protection
Culvert & Drain Outlet Riprap Apron Sizing Calculator
Open calculator
Energy Dissipation & Scour Protection
Drop Structure & Weir Plunge-Pool Scour Depth Calculator
Open calculator
Geotechnical & Retaining Structures
Shallow Strip Foundation Bearing Capacity Calculator
Open calculator
Geotechnical & Retaining Structures
Rainfall Infiltration & Shallow Infinite-Slope Stability FS(t) Calculator
Open calculator
Geotechnical & Retaining Structures
Laterally Loaded Pile Calculator
Open calculator
Engineering Utilities
Civil, Structural & Hydraulic Engineering Unit Converter
Open calculator
Geotechnical & Retaining Structures
Cantilever & Gravity Retaining Wall Stability Calculator
Open calculator
Geotechnical & Retaining Structures
Circular Slope Stability Calculator — Bishop's Simplified Method
Open calculator
Geotechnical & Retaining Structures
SPT Soil Liquefaction Triggering Calculator
Open calculator
Energy Dissipation & Scour Protection
Gravity Check Dam Spillway, Freeboard & Downstream Apron Calculator
Open calculator
Stormwater Detention & Roadway Drainage
On-Site Stormwater Detention Volume Calculator
Open calculator
Energy Dissipation & Scour Protection
Vertical Drop Structure & Stilling Basin Sizing Calculator
Open calculator
Energy Dissipation & Scour Protection
Steep-Slope Drainage Channel Drop-Step Spacing Calculator
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
Bridge Crossing: Backwater and Scour
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
Box Culvert Structural Design
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
Liquid-Retaining Structure Design
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
PAS 2080 Carbon Screening
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
Counterfort Retaining Wall RC Design
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
Elasto-Plastic Diaphragm Wall Staged Excavation
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
Pile Cap Shear and Reinforcement
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
Storm Sewer Longitudinal Profile, HGL & Utility Clearance Check
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
Road Alignment Check
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
AASHTO 1993 Flexible Pavement Structural Number (SN) Check
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
Formwork Shoring (Steel Tube Posts) Check
Open calculator
Need to edit terrain, 2D flood models and design alternatives interactively on your computer, or see 3D views drawn from your project data? Use the HydroStudio desktop edition:
Download the desktop trial
No credit card or phone number is needed to download. Without a licence it runs as a trial: local calculation and 3D viewing work, exported reports and drawings carry a trial watermark (not for submission), and some built-in data libraries are limited. Plans and prices are on the Pricing page.