Check Summary Preview (Software Format; Auto-Populated)
| Check item | Trial value | Status |
|---|---|---|
| Normal Depth yn | 0.6193 m | Calculated value |
| Flow Velocity V | 2.219 m/s | Calculated value |
| Froude Number Fr | 1.042 | Calculated value |
| Critical Depth yc | 0.6340 m | Calculated value |
Summary of the online calculation (software format) for checking by the designer and an independent checker. Final sign-off remains the responsibility of the chartered or registered engineer.
Desktop edition: calculation reports and cross-module quantity reconciliation
1. Calculation reports: with a licence, the desktop edition writes Word (.docx) and Excel (.xlsx) calculation reports and DXF drawings without the trial watermark, listing the inputs, the equations used and the results; in trial mode the step-by-step detail is hidden. For this calculator alone, licensed users can also sign in on the calculator above and formally export a single-tool Word report (with a verification code) and DXF drawing. The Pro plan (all modules) is US$990 per year; see Pricing for monthly, perpetual and team plans.
2. Cross-module reconciliation: desktop project runs carry the design peak flow into downstream channel, culvert and bridge hydraulics; terrain cut/fill into the earthwork balance, cost and carbon tables; structural concrete, formwork and rebar take-off into the cost and carbon tables; slope and excavation safety-factor thresholds into construction monitoring trigger levels.
3. Independent checking engineers, authority reviewers and academics can request a complimentary review or teaching licence (link below).
1. Governing Equations & SI Nomenclature
The equations the calculation core applies are summarised below for independent checking.
The equations below summarise the method that the calculation core applies on this page. The design basis it reports is: Manning Uniform Flow & Critical Depth Q²T/(gA³) = 1; velocity limits (when a lining is selected) per Taiwan Soil and Water Conservation Technical Regulations Art. 85. The worked example further down lists the core's own calculation steps for the standard example.
2. Worked Standard Example (Computed by the Calculation Core)
The worked example below was computed by the calculation core when this page was built; entering the same inputs above reproduces it.
Design Scenario — Trapezoidal Drain Normal & Critical Depth Check (Q = 2.50 m³/s, b = 1.20 m): Determine the normal depth yn, critical depth yc, velocity and Froude number of a trapezoidal drain (bottom width 1.20 m, side slopes 1V:1H, n = 0.015) carrying Q = 2.50 m³/s at S = 0.004 m/m. No lining is selected, so no velocity check is made in this example.
The inputs below were passed to the calculation core (WebAssembly) when this page was built; every step, result and check shown here is the core's own output. Basis reported by the core: Manning Uniform Flow & Critical Depth Q²T/(gA³) = 1; velocity limits (when a lining is selected) per Taiwan Soil and Water Conservation Technical Regulations Art. 85
Inputs Passed to the Calculation Core
| Parameter | Value | Unit |
|---|---|---|
| Cross-Section Shape | Trapezoidal | — |
| Bottom Width b | 1.2 | m |
| Side Slope z | 1 | — |
| Manning n | 0.015 | — |
| Longitudinal Slope S | 0.004 | m/m |
| Design Discharge Q | 2.5 | m³/s |
| Channel Lining Material | No velocity check | — |
| Perennial Flow | No | — |
Calculation Steps (calculation core output)
[HyGeoWorks online preview - not for PE sealing or submittal]
- Section: Trapezoidal b = 1.200 m, side slope 1:1; n = 0.015, S = 0.004, Q = 2.5 m³/s
- Normal depth: solve y for Q(y) = A·R^(2/3)·S^(1/2)/n = 2.5 → yn = 0.6193 m
- A = (b + z·y)·y = (1.2000 + 1×0.6193)×0.6193 = 1.12676 m²
- P = b + 2y·√(1 + z²) = 1.2000 + 2×0.6193×√(1 + 1²) = 2.95172 m
- T = b + 2z·y = 2.43865 m
- V = Q/A = 2.5/1.12676 = 2.2188 m/s
- Fr = V/√(g·A/T) = 1.042 (Supercritical)
- Critical depth: Q²·T/(g·A³) = 1 → yc = 0.6340 m (yn ≤ yc)
Computed Results (calculation core output)
| Output Parameter | Calculated Value | SI Unit |
|---|---|---|
| Normal Depth yn | 0.6193 | m |
| Flow Velocity V | 2.219 | m/s |
| Froude Number Fr | 1.042 | — |
| Critical Depth yc | 0.6340 | m |
3. Regional Design Options in This Edition: UK, EU, Singapore, Malaysia, Hong Kong & Australia
Symbols and units are SI unless stated otherwise.
- This calculator: the design basis is the one reported by the calculation core: Manning Uniform Flow & Critical Depth Q²T/(gA³) = 1; velocity limits (when a lining is selected) per Taiwan Soil and Water Conservation Technical Regulations Art. 85. The options listed below belong to the calculators named in each item.
- United Kingdom, Ireland & European Union: The retaining wall and slope stability calculators default to EN 1997-1:2004 Design Approach 1 (Combination 1 & Combination 2); the UK National Annex and 2nd-Gen EN 1997-1:2024 / EN 1997-3:2025 (MFA, and RFA for retaining walls) are selectable there, as are DA2 for retaining walls and DA3 for slopes. The retaining wall calculator lets γG, γQ and γφ' be overridden for a National Annex and designs metric H-bars (H10–H32) when concrete and steel strengths are entered.
- Singapore & Malaysia: The retaining wall calculator offers SS EN 1997-1:2010 with the Singapore National Annex, and the detention calculator offers a DID Malaysia MSMA 2nd Edition (2012) Equation 2.2 IDF rainfall mode besides directly entered design intensities.
- Hong Kong SAR: HyGeoWorks does not claim Hong Kong Buildings Department pre-accepted program status; the retaining wall calculator's HK GEO Geoguide 1 option shows the calculation core's steps and checks so that the result can be checked independently. With that option the calculation core applies the Geoguide 1 Table 6 and Table 7 partial factors at ULS and the §9.2.4 middle-third eccentricity check at SLS.
- Australia & New Zealand: No ARR 2019 IFD data is built in; design rainfall intensities for any AEP can be entered directly in the detention calculator. The HydroStudio desktop edition supports GDA2020 / MGA2020 zones 46–59 as well as WGS 84 / UTM zones.
4. Frequently Asked Questions
Common questions about this calculator are answered below. Final sign-off remains the responsibility of the chartered or registered engineer.
Why compute both normal depth yn and critical depth yc?
Comparing yn with yc shows whether the reach is hydraulically mild (yn > yc, subcritical, controlled from downstream) or steep (yn < yc, supercritical, controlled from upstream). This sets the direction in which water-surface profiles are computed and where hydraulic jumps can form.
When does the calculator check velocity, and against which limits?
Only when a channel lining is selected. The calculation core then compares the velocity with the permissible values of Taiwan Soil and Water Conservation Technical Regulations Art. 85 for that lining. With "No velocity check" selected, as in the example on this page, only depths, velocity and Froude number are reported.
Why can a circular pipe carry more than its full-bore flow?
Near the crown the wetted perimeter grows faster than the flow area, so the hydraulic radius falls and the maximum discharge occurs slightly below full depth. The calculation core limits the normal-depth search to the depth of maximum discharge and reports no solution when the design flow exceeds the pipe's capacity.
When is normal depth not a sufficient answer?
Normal depth applies to long prismatic reaches away from controls such as gates, culverts, outfalls or tailwater. Near such controls a gradually varied flow profile is needed. The HydroStudio desktop edition includes standard-step water-surface profiles and a 1D drainage network coupled with a 2D shallow-water surface model.
5. Explore All 30 Calculators (SI Edition; Design Basis Stated on Each Page)
Each calculator below states its own design basis on its page; several apply Taiwan regulations and say so.