HyGeoWorks
Previews run in your browser; inputs are sent only when you formally export. Online previews are not for formal submission.
HyGeoWorks / International SI Metric Tools / Reference Calculators (Design Basis Stated on Each Page)

Liquid-Retaining Structure Design (Detention / Sediment Basin, Tank, U-Channel)

Overall flotation of buried detention / sediment basins, reservoirs and U-shaped open channels (with quantified options when insufficient), two-face reinforcement of walls and base slab, and crack control for liquid tightness (code bar spacing, crack width or steel stress limit).

Design basis and scope notes for this page ▾
Taiwan Design Code for Concrete Structures (2023) Arts. 5.3.6, 5.3.7, 7.6.1.1, 22.5, 24.3.2; flotation per Taiwan Building Foundation Design Code Art. 2.12; optional direct crack width per EN 1992-1-1 7.3.4 / EN 1992-3 7.3.1 (not ACI 350)
Design basis as reported by the calculation core: Taiwan Design Code for Concrete Structures (2023) Arts. 5.3.6, 5.3.7, 7.6.1.1, 22.5, 24.3.2; flotation per Taiwan Building Foundation Design Code Art. 2.12; optional direct crack width per EN 1992-1-1 7.3.4 / EN 1992-3 7.3.1 (not ACI 350)
Design follows the Taiwan codes named in the basis line; the direct crack-width option uses the EN 1992 clauses named there. This is a Taiwan-code calculation offered for reference: bar sizes are D13–D32 and strengths are entered in kgf/cm².

Recalculates in your browser as you edit inputs; Free sample Word report and DXF for this calculator; With a licence: formal Word and DXF export, plus online project reports from the Project List.

Free samples and pricing
A public sample produced by the production service from this page's standard example and sealed with a verification code: open it in Word or AutoCAD and check it on the Verify page. Not for formal submission.
Single-export pass: US$19 for one calculator, 3 formal exports in total within 24 hours of the first; full credit toward an upgrade within 30 days, full refund before the first export
Single-export passes (one calculator, 3 exports within 24 hours), 30-day passes, annual plans and perpetual licences; printable quotes for purchase orders.
Formal export and the Project List are on the workbench toolbar above:
Licensed users can formally export this calculator's Word report (with a verification code and server time witness) and AutoCAD DXF drawing, or add several calculators to the free Project List and export a multi-chapter project report online, with nothing to install on a Mac. Projects with DEM terrain or GIS files can run in the heavy cloud computation or in the HydroStudio desktop edition.
The summary lists the basis, key results and check verdicts; its first line marks it as an online preview, not for formal submission.
Download the offline workbench (single HTML file, 39 tools)
No install and no email required. It contains the same calculation core as this site; results are also a preview, not for formal submission.

Check Summary Preview (Software Format; Auto-Populated)

Liquid-Retaining Structure Design (Detention / Sediment Basin, Tank, U-Channel): check summary (software format)
Calculation basis: Taiwan Design Code for Concrete Structures (2023) Arts. 5.3.6, 5.3.7, 7.6.1.1, 22.5, 24.3.2; flotation per Taiwan Building Foundation Design Code Art. 2.12; optional direct crack width per EN 1992-1-1 7.3.4 / EN 1992-3 7.3.1 (not ACI 350)
Check item Trial value Status
Wall Outer face: φMn ≥ Mu and minimum steel63.68 kN·m/m ≥ 62.50OK
Wall Outer face: crack control17.5 cm ≤ 31.5OK
Wall Inner face: φMn ≥ Mu and minimum steel49.82 kN·m/m ≥ 35.75OK
Wall Inner face: crack control22.5 cm ≤ 40.3OK
Wall: φVc ≥ Vu158.93 kN/m ≥ 54.71OK
Bottom slab Outer face: φMn ≥ Mu and minimum steel81.78 kN·m/m ≥ 71.06OK

Summary of the online calculation (software format) for checking by the designer and an independent checker. Final sign-off remains the responsibility of the chartered or registered engineer.

Desktop edition: calculation reports and cross-module quantity reconciliation

1. Calculation reports: with a licence, the desktop edition writes Word (.docx) and Excel (.xlsx) calculation reports and DXF drawings without the trial watermark, listing the inputs, the equations used and the results; in trial mode the step-by-step detail is hidden. For this calculator alone, licensed users can also sign in on the calculator above and formally export a single-tool Word report (with a verification code) and DXF drawing. The Pro plan (all modules) is US$990 per year; see Pricing for monthly, perpetual and team plans.
2. Cross-module reconciliation: desktop project runs carry the design peak flow into downstream channel, culvert and bridge hydraulics; terrain cut/fill into the earthwork balance, cost and carbon tables; structural concrete, formwork and rebar take-off into the cost and carbon tables; slope and excavation safety-factor thresholds into construction monitoring trigger levels.
3. Independent checking engineers, authority reviewers and academics can request a complimentary review or teaching licence (link below).

Desktop pricing (Pro US$990/yr) Download the desktop trial Complimentary licence for checkers, reviewers and academics
Scope and responsibility: This page is a single-calculator trial run; cross-module quantity reconciliation is done in desktop project runs. Problems outside this calculator's scope (see the FAQ) need an appropriate analysis method. Final sign-off remains the responsibility of the chartered or registered engineer.

1. Worked Standard Example (Computed by the Calculation Core)

The worked example below was computed by the calculation core when this page was built; entering the same inputs above reproduces it.

Design Scenario — Standard example (calculation core defaults): The standard example uses the default inputs of the calculation core. Every number below was produced by the core when this page was built; nothing on this page is computed by hand.

The inputs below were passed to the calculation core (WebAssembly) when this page was built; every step, result and check shown here is the core's own output. Basis reported by the core: Taiwan Design Code for Concrete Structures (2023) Arts. 5.3.6, 5.3.7, 7.6.1.1, 22.5, 24.3.2; flotation per Taiwan Building Foundation Design Code Art. 2.12; optional direct crack width per EN 1992-1-1 7.3.4 / EN 1992-3 7.3.1 (not ACI 350)

Inputs Passed to the Calculation Core

ParameterValueUnit
Structure TypeOpen top (U-channel, open sediment basin; cantilever walls)—
Clear Width4m
Clear Height2.5m
Wall Thickness0.3m
Base Slab Thickness0.35m
Base Slab Projection0m
External Backfill Height(blank)m
Backfill Unit Weight18kN/m³
Backfill Saturated Unit Weight20kN/m³
Lateral Earth Pressure Coefficient(blank)—
Surface Surcharge10kPa
External Groundwater Level(blank)m
Internal Water Depth(blank)m
Required Flotation Safety Factor(blank)—
Allowable Uplift Resistance of Anchors / Tension Piles(blank)kN/m
Concrete Strength f'c280kgf/cm²
Rebar Yield Strength fy4200kgf/cm²
Minimum Tension Steel Ratio(blank)—
Bar SizeSelected by program—
Crack Control MethodTaiwan concrete code Art. 24.3.2 maximum bar spacing—
Basin Length(blank)m

Calculation Steps (calculation core output)

[HyGeoWorks online preview - not for PE sealing or submittal]

  1. Outer width 4.60 m (full base width 4.60 m), outer height 2.85 m; concrete 3.110 m³/m; internal water depth 2.50 m; external backfill height 2.85 m
  2. Load combinations: U1 = 1.4(D + F), U2 = 1.2D + 1.6H + 1.6L, U3 = 1.2(D + F) + 0.9H; service S1 = D + F, S2 = D + H + L, S3 = D + F + H

Computed Results (calculation core output)

Output ParameterCalculated ValueSI Unit
Max flexural utilization Mu / φMn0.982—
Max shear utilization Vu / φVc0.344—
Max crack control utilization (value / limit)0.626—
Rebar weight (estimate)152.9kg/m
Concrete3.110m³/m

Verification Checks (calculation core output)

Verification CheckComputed ValueCriterionVerdictBasis
Wall Outer face: φMn ≥ Mu and minimum steel63.68 kN·m/m≥ 62.50OKTaiwan Design Code for Concrete Structures (2023)
Wall Outer face: crack control17.5 cm≤ 31.5OK—
Wall Inner face: φMn ≥ Mu and minimum steel49.82 kN·m/m≥ 35.75OKTaiwan Design Code for Concrete Structures (2023)
Wall Inner face: crack control22.5 cm≤ 40.3OK—
Wall: φVc ≥ Vu158.93 kN/m≥ 54.71OKTaiwan Design Code for Concrete Structures (2023)
Bottom slab Outer face: φMn ≥ Mu and minimum steel81.78 kN·m/m≥ 71.06OKTaiwan Design Code for Concrete Structures (2023)
Bottom slab Outer face: crack control15.0 cm≤ 31.6OK—
Bottom slab Inner face: φMn ≥ Mu and minimum steel60.57 kN·m/m≥ 57.68OKTaiwan Design Code for Concrete Structures (2023)
Bottom slab Inner face: crack control20.0 cm≤ 31.9◇ Not judged
Not judged: This section is in axial tension under the governing service load combination: the service steel stress fs is calculated on the cracked section in flexure without the axial force, so fs may be underestimated (the bar spacing limit or steel stress limit checked against it is unconservative); until a tension-and-flexure section model and an independent worked example are in place, this program makes no crack control judgement; the calculated values are listed for reference.
—
Bottom slab: φVc ≥ Vu91.60 kN/m≥ 15.95OKTaiwan Design Code for Concrete Structures (2023)
Reinforcement and crack control (per metre of length) (4 rows)
MemberTension faceMu (kN·m)Ms (kN·m)Required As (cm²)Bars @ spacing (cm)φMn (kN·m)fs (kgf/cm²)Crack control: value / limitVerdict
WallOuter face62.5039.067.10D13@17.563.68241717.5/31.5 cmPASS
WallInner face35.7525.545.40D13@22.549.82201622.5/40.3 cmPASS
Bottom slabOuter face71.0643.847.31D13@15.081.78211215.0/31.6 cmPASS
Bottom slabInner face57.6841.206.30D13@20.060.57239420.0/31.9 cmNot judged
Shear (2 rows)
MemberThickness (cm)Vu (kN)φVc (kN)Vc basisGoverning combination
Wall3054.71158.930.53λ√fc'·bw·dU2 = 1.2D + 1.6H + 1.6L (empty, external earth and water pressure)
Bottom slab3515.9591.60Table 22.5.5.1(c) with size effect λs (Art. 22.5.5.1.3)U2 = 1.2D + 1.6H + 1.6L (empty, external earth and water pressure)

Assumptions and Limits Stated by the Calculation Core

2. Frequently Asked Questions

Common questions about this calculator are answered below. Final sign-off remains the responsibility of the chartered or registered engineer.

Which design basis does this calculator apply?

Taiwan Design Code for Concrete Structures (2023) Arts. 5.3.6, 5.3.7, 7.6.1.1, 22.5, 24.3.2; flotation per Taiwan Building Foundation Design Code Art. 2.12; optional direct crack width per EN 1992-1-1 7.3.4 / EN 1992-3 7.3.1 (not ACI 350). Design follows the Taiwan codes named in the basis line; the direct crack-width option uses the EN 1992 clauses named there. This is a Taiwan-code calculation offered for reference: bar sizes are D13–D32 and strengths are entered in kgf/cm².

What assumptions and limits does the calculation core state for this tool?

Load classification (Taiwan Design Code for Concrete Structures (2023) Arts. 5.3.6, 5.3.7): the contained liquid is fluid load F, with the same load factors and combinations as dead load; external earth pressure and pore-water pressure are H (1.6; 0.9 where permanent and counteracting the primary load). Lateral earth pressure coefficient K = 0.5 (0.5 when not given: the Taiwan Building Foundation Design Code (2023) Art. 7.3.1 requires an at-rest coefficient of not less than 0.5, to be raised for overconsolidated soil); backfill surface height 2.85 m, groundwater height 0.00 m (above underside of base slab). Analysis model: plane frame on member centrelines with uniform base reaction; section strength design includes axial tension (flexure and shear) and neglects axial compression (conservative). Not covered: two-way slab action along the tank length and partition walls, restrained thermal and shrinkage effects, seismic hydrodynamic pressure, design of construction joints and waterstops. Sections in axial tension (Taiwan Design Code for Concrete Structures (2023) Arts. 22.2 and 22.4, tension-controlled φ = 0.90): where the moment about the tension steel Ms = Mu − Nu(d − h/2) > 0, As = As(Ms) + Nu/(φfy); where Ms ≤ 0 (whole section in tension, concrete neglected), moments are taken about the other layer, As = [Nu(h/2 − d') + Mu]/[φfy(d − d')], with d' estimated as the other face cover plus half the same bar diameter. Shear Vc includes Nu/(6Ag) (Table 22.5.5.1; tension negative, Vc not less than 0). Crack control: maximum bar spacing of Art. 24.3.2 (using the calculated service-load steel stress). This is a general building provision and does not address liquid tightness; where tightness matters, use the crack width or steel stress limit method. This section is in axial tension under the governing service load combination: the service steel stress fs is calculated on the cracked section in flexure without the axial force, so fs may be underestimated (the bar spacing limit or steel stress limit checked against it is unconservative); until a tension-and-flexure section model and an independent worked example are in place, this program makes no crack control judgement; the calculated values are listed for reference. BS EN 1992-3 Clause 7.3.1 Tightness Class 1 reference (paid standard) (source text not obtained in this verification; not verified): hydrostatic head / wall thickness hD/h = 8.3 -> interpolated crack width limit wk,max = 0.183 mm.

Where is the calculation performed, and can the result be sealed or submitted?

The calculation runs in your browser, in the same WebAssembly calculation core this page loads. The result is an online preview: its first line reads "[HyGeoWorks online preview - not for PE sealing or submittal]".

Can I recalculate without a network connection?

Yes. "Download the offline workbench" on this page saves one HTML file that contains the workbench and the same calculation core; opened from disk it recalculates without a network connection.

From the Online Preview to the HydroStudio Desktop Edition

The free preview has no Word report, DXF drawing or verification code. Licensed users can sign in on the calculator and formally export a single-tool Word report (with a verification code) and DXF drawing, or combine several calculators in the Project List and export a multi-chapter project report online; projects with terrain or GIS files can run in the heavy cloud computation, and interactive 2D models and large simulations use the desktop edition. Export a .toml project file from the calculator and open it in the HydroStudio desktop edition (Windows 10/11, 64-bit); fields that the online tool does not cover are marked as placeholders and must be completed there before calculating. With a licence, the desktop edition writes Word (.docx) calculation reports, Excel (.xlsx) workbooks with live formulas and .dxf drawings without the trial watermark, and also includes 2D shallow-water flood modelling (Godunov finite volume) and 2D finite-element variably saturated seepage.

✓ USD checkout via Stripe  ·  ✓ Printable USD quotation (print or save as PDF)  ·  ✓ Ed25519-signed licence with a 14-day offline lease
Desktop Licence Pricing (USD)
$990 USD / year (Pro, all modules)
Also available: Pro monthly at $119/month, a single-discipline annual licence at $590/yr and a 30-day single-discipline pass at $79. Purchasing approval follows your organisation's own rules.
View USD Pricing & Printable Quotation →

3. Explore All 30 Calculators (SI Edition; Design Basis Stated on Each Page)

Each calculator below states its own design basis on its page; several apply Taiwan regulations and say so.

Open-Channel & Pipe Hydraulics
Manning Open-Channel & Circular Pipe Flow Calculator
Open calculator
Open-Channel & Pipe Hydraulics
Manning Normal Depth (yn) & Critical Depth (yc) Calculator
Open calculator
Open-Channel & Pipe Hydraulics
Pipe Diameter & Channel Bottom Width Sizing Calculator
Open calculator
Stormwater Detention & Roadway Drainage
Detention Outlet Orifice & Rectangular Weir Sizing Calculator
Open calculator
Stormwater Detention & Roadway Drainage
Gutter Flow Spread & Kerb / Grate Inlet Interception Calculator
Open calculator
Open-Channel & Pipe Hydraulics
Box & Circular Pipe Culvert Inlet / Outlet Control Calculator
Open calculator
Energy Dissipation & Scour Protection
Culvert & Drain Outlet Riprap Apron Sizing Calculator
Open calculator
Energy Dissipation & Scour Protection
Drop Structure & Weir Plunge-Pool Scour Depth Calculator
Open calculator
Geotechnical & Retaining Structures
Shallow Strip Foundation Bearing Capacity Calculator
Open calculator
Geotechnical & Retaining Structures
Rainfall Infiltration & Shallow Infinite-Slope Stability FS(t) Calculator
Open calculator
Geotechnical & Retaining Structures
Laterally Loaded Pile Calculator
Open calculator
Engineering Utilities
Civil, Structural & Hydraulic Engineering Unit Converter
Open calculator
Geotechnical & Retaining Structures
Cantilever & Gravity Retaining Wall Stability Calculator
Open calculator
Geotechnical & Retaining Structures
Circular Slope Stability Calculator — Bishop's Simplified Method
Open calculator
Geotechnical & Retaining Structures
SPT Soil Liquefaction Triggering Calculator
Open calculator
Energy Dissipation & Scour Protection
Gravity Check Dam Spillway, Freeboard & Downstream Apron Calculator
Open calculator
Stormwater Detention & Roadway Drainage
On-Site Stormwater Detention Volume Calculator
Open calculator
Energy Dissipation & Scour Protection
Vertical Drop Structure & Stilling Basin Sizing Calculator
Open calculator
Energy Dissipation & Scour Protection
Steep-Slope Drainage Channel Drop-Step Spacing Calculator
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
Bridge Crossing: Backwater and Scour
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
Box Culvert Structural Design
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
Liquid-Retaining Structure Design
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
PAS 2080 Carbon Screening
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
Counterfort Retaining Wall RC Design
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
Elasto-Plastic Diaphragm Wall Staged Excavation
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
Pile Cap Shear and Reinforcement
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
Storm Sewer Longitudinal Profile, HGL & Utility Clearance Check
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
Road Alignment Check
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
AASHTO 1993 Flexible Pavement Structural Number (SN) Check
Open calculator
Reference Calculators (Design Basis Stated on Each Page)
Formwork Shoring (Steel Tube Posts) Check
Open calculator
Need to edit terrain, 2D flood models and design alternatives interactively on your computer, or see 3D views drawn from your project data? Use the HydroStudio desktop edition:
Download the desktop trial
No credit card or phone number is needed to download. Without a licence it runs as a trial: local calculation and 3D viewing work, exported reports and drawings carry a trial watermark (not for submission), and some built-in data libraries are limited. Plans and prices are on the Pricing page.