Check Summary Preview (Software Format; Auto-Populated)
| Check item | Trial value | Status |
|---|---|---|
| Dead load + construction live load | 1306.50 kgf/m² ≥ 490.00 kgf/m² | OK |
| Construction live load | 100.00 kgf/m² ≥ 100.00 kgf/m² | OK |
| Concrete unit weight | 2570.00 kgf/m³ ≥ 2570.00 kgf/m³ | OK |
| Post slenderness KL/r | 88.13 ≤ 180.00 | OK |
| Post axial force ≤ allowable axial force | 16.21 kN ≤ 36.63 kN | OK |
| Vertical spacing of horizontal ties | 1.80 m ≤ 2.00 m | OK |
Summary of the online calculation (software format) for checking by the designer and an independent checker. Final sign-off remains the responsibility of the chartered or registered engineer.
Desktop edition: calculation reports and cross-module quantity reconciliation
1. Calculation reports: with a licence, the desktop edition writes Word (.docx) and Excel (.xlsx) calculation reports and DXF drawings without the trial watermark, listing the inputs, the equations used and the results; in trial mode the step-by-step detail is hidden. For this calculator alone, licensed users can also sign in on the calculator above and formally export a single-tool Word report (with a verification code) and DXF drawing. The Pro plan (all modules) is US$990 per year; see Pricing for monthly, perpetual and team plans.
2. Cross-module reconciliation: desktop project runs carry the design peak flow into downstream channel, culvert and bridge hydraulics; terrain cut/fill into the earthwork balance, cost and carbon tables; structural concrete, formwork and rebar take-off into the cost and carbon tables; slope and excavation safety-factor thresholds into construction monitoring trigger levels.
3. Independent checking engineers, authority reviewers and academics can request a complimentary review or teaching licence (link below).
1. Worked Standard Example (Computed by the Calculation Core)
The worked example below was computed by the calculation core when this page was built; entering the same inputs above reproduces it.
Design Scenario — Standard example (calculation core defaults): The standard example uses the default inputs of the calculation core. Every number below was produced by the core when this page was built; nothing on this page is computed by hand.
The inputs below were passed to the calculation core (WebAssembly) when this page was built; every step, result and check shown here is the core's own output. Basis reported by the core: MOTC (Taiwan) Highway Construction Specifications (2013-01) Sec. 01525, 2.3; post allowable axial force per MOTC (Taiwan) Highway Bridge Design Code (2009 provisions) Ch. 9 allowable stress design scaled to a safety factor of 2.5; Taiwan Standards for Construction Safety and Health Facilities Art. 131
Inputs Passed to the Calculation Core
| Parameter | Value | Unit |
|---|---|---|
| Temporary Works Type | Formwork shoring (steel tube posts) | — |
| Thickness of Concrete Slab to be Placed | 0.45 | m |
| Self-Weight of Formwork and Shoring | 50 | kgf/m² |
| Post Spacing, Longitudinal | 1 | m |
| Post Spacing, Transverse | 1 | m |
| Steel Tube Post Outside Diameter | 60.5 | mm |
| Steel Tube Post Wall Thickness | 2.8 | mm |
| Total Shoring Post Height | 5.4 | m |
| Vertical Spacing of Horizontal Ties | 1.8 | m |
| Formwork Area per Pour | 350 | m² |
| Tiered Single Post Shores | No | — |
Calculation Steps (calculation core output)
[HyGeoWorks online preview - not for PE sealing or submittal]
- Vertical load: dead 1206 + construction live 100 + impact 347 = 1653 kgf/m²; tributary area 1.00 m² per post → post axial force 16.21 kN
- Tube A = 5.08 cm², r = 2.04 cm, KL/r = 88.1 → allowable axial force 36.63 kN; minimum design horizontal force 0.24 kN per post
Computed Results (calculation core output)
| Output Parameter | Calculated Value | SI Unit |
|---|---|---|
| Post axial force | 16.21 | kN |
| Post allowable axial force (safety factor 2.5) | 36.63 | kN |
| Post slenderness KL/r | 88.1 | — |
| Design vertical load | 1653 | kgf/m² |
| Minimum design horizontal force per post | 0.24 | kN |
Verification Checks (calculation core output)
| Verification Check | Computed Value | Criterion | Verdict | Basis |
|---|---|---|---|---|
| Dead load + construction live load | 1306.50 kgf/m² | ≥ 490.00 kgf/m² | OK | MOTC (Taiwan) Highway Construction Specifications (2013-01) Sec. 01525, 2.3 (2.3.3: at least 490 kgf/m²) |
| Construction live load | 100.00 kgf/m² | ≥ 100.00 kgf/m² | OK | MOTC (Taiwan) Highway Construction Specifications (2013-01) Sec. 01525, 2.3 (2.3.3: uniform load not less than 100 kgf/m²) |
| Concrete unit weight | 2570.00 kgf/m³ | ≥ 2570.00 kgf/m³ | OK | MOTC (Taiwan) Highway Construction Specifications (2013-01) Sec. 01525, 2.3 (2.3.3: not less than 2,570 kgf/m³) |
| Post slenderness KL/r | 88.13 | ≤ 180.00 | OK | MOTC (Taiwan) Highway Construction Specifications (2013-01) Sec. 01525, 2.3 (Table 01525-6: main compression steel members ≤ 180) |
| Post axial force ≤ allowable axial force | 16.21 kN | ≤ 36.63 kN | OK | MOTC (Taiwan) Highway Construction Specifications (2013-01) Sec. 01525, 2.3 (2.3.5: safety factor not less than 2.5); MOTC (Taiwan) Highway Bridge Design Code (2009 provisions) Ch. 9 allowable stress design Table 9.8 |
| Vertical spacing of horizontal ties | 1.80 m | ≤ 2.00 m | OK | MOTC (Taiwan) Highway Construction Specifications (2013-01) Sec. 01525, 2.3 (adjustable steel tube posts higher than 3.5 m need horizontal ties in both directions every 2 m) |
Assumptions and Limits Stated by the Calculation Core
- Loads per MOTC (Taiwan) Highway Construction Specifications (2013-01) Sec. 01525, 2.3: dead load (concrete 1156 kgf/m² + formwork 50 kgf/m²), construction live load 100 kgf/m², impact load (30% of the placed concrete weight) 347 kgf/m²; the minimum design horizontal force of each support member is 2% of the supported dead load (0.24 kN per post), which must be carried by braces or ties to a stable support
- Not included: wind, earthquake, stream flow force, concentrated loads from construction equipment, overturning stability (safety factor 1.2), deflection (L/240), prefabricated shoring frames (per the manufacturer's test data; working load not more than 40% of the maximum tested load)
- Taiwan Standards for Construction Safety and Health Facilities Art. 131: formwork shoring with a height of 7 m or more and an area of 330 m² or more must be designed and signed off by a full-time engineer or a licensed professional engineer; this tool does not apply the Ministry of the Interior (Taiwan) Design Code for Scaffolds and Formwork Shoring; check it separately
2. Frequently Asked Questions
Common questions about this calculator are answered below. Final sign-off remains the responsibility of the chartered or registered engineer.
Which design basis does this calculator apply?
MOTC (Taiwan) Highway Construction Specifications (2013-01) Sec. 01525, 2.3; post allowable axial force per MOTC (Taiwan) Highway Bridge Design Code (2009 provisions) Ch. 9 allowable stress design scaled to a safety factor of 2.5; Taiwan Standards for Construction Safety and Health Facilities Art. 131. Loads, allowable stresses and thresholds follow the Taiwan specifications named in the basis line; they are not BS 5975, OSHA or other national rules. Use the result as a reference calculation.
What assumptions and limits does the calculation core state for this tool?
Loads per MOTC (Taiwan) Highway Construction Specifications (2013-01) Sec. 01525, 2.3: dead load (concrete 1156 kgf/m² + formwork 50 kgf/m²), construction live load 100 kgf/m², impact load (30% of the placed concrete weight) 347 kgf/m²; the minimum design horizontal force of each support member is 2% of the supported dead load (0.24 kN per post), which must be carried by braces or ties to a stable support. Not included: wind, earthquake, stream flow force, concentrated loads from construction equipment, overturning stability (safety factor 1.2), deflection (L/240), prefabricated shoring frames (per the manufacturer's test data; working load not more than 40% of the maximum tested load). Taiwan Standards for Construction Safety and Health Facilities Art. 131: formwork shoring with a height of 7 m or more and an area of 330 m² or more must be designed and signed off by a full-time engineer or a licensed professional engineer; this tool does not apply the Ministry of the Interior (Taiwan) Design Code for Scaffolds and Formwork Shoring; check it separately.
Where is the calculation performed, and can the result be sealed or submitted?
The calculation runs in your browser, in the same WebAssembly calculation core this page loads. The result is an online preview: its first line reads "[HyGeoWorks online preview - not for PE sealing or submittal]".
Can I recalculate without a network connection?
Yes. "Download the offline workbench" on this page saves one HTML file that contains the workbench and the same calculation core; opened from disk it recalculates without a network connection.
3. Explore All 30 Calculators (SI Edition; Design Basis Stated on Each Page)