Previews run in your browser; inputs are sent only when you formally export. Online previews are not for formal submission.
HyGeoWorks / International SI Metric Engineering Hub
Civil, hydraulic and geotechnical calculators in SI units
30 calculators for engineers working in SI units in the UK, Ireland, Europe, Singapore, Malaysia, Hong Kong, Australia and New Zealand. Previews run in your browser; licensed users can formally export a single-tool Word report or DXF drawing, and the desktop edition produces whole-project calculation reports.
Each page states the design basis the calculation core applies. Retaining wall and slope calculators offer Eurocode 7 options. Several hydraulic calculators, and most of the reference calculators listed under "Reference Calculators (Design Basis Stated on Each Page)", apply Taiwan regulations (for example the permissible velocities of the Taiwan Soil and Water Conservation Technical Regulations, Art. 85). Bridge scour follows FHWA HEC-18, pavement follows the AASHTO 1993 Guide, and the carbon calculator gives a three-stage upfront estimate (A1–A5) with factors attributed to UK DESNZ; check each factor against the edition your project requires.
EN 1997-1 DA1 (Comb. 1 & 2): walls & slopes2nd-Gen EN 1997-1:2024 / EN 1997-3:2025 (MFA; RFA for walls)UK NA (walls & slopes) & Singapore SS EN 1997 NA (walls)HK GEO Geoguide 1 option (walls)DID Malaysia MSMA 2nd Ed. IDF option (detention)GDA2020 / MGA2020 & WGS 84 / UTM (Desktop)
Hong Kong & Open Government Licence notice: HyGeoWorks does not claim Hong Kong Buildings Department pre-accepted program status; the retaining wall calculator's HK GEO Geoguide 1 option shows the calculation core's steps and checks so that the result can be checked independently. The carbon calculator's UK DESNZ greenhouse gas conversion factors contain public sector information licensed under the Open Government Licence v3.0.
Discipline
Design basis
No calculators match these filters.
Open-Channel & Pipe Hydraulics
Basis: Manning Uniform Flow Equation V = (1/n)·R^(2/3)·S^(1/2) (SI / Chow, 1959). Verification cases, tolerances and actual differences for the calculation core are listed on the Benchmarks page.
Uniform-flow calculation with the Manning equation for trapezoidal, rectangular and circular sections at a given flow depth. The calculation core reports flow area, wetted perimeter, hydraulic radius, velocity, discharge, top width and Froude number; this page makes no velocity or freeboard check.
Normal depth from the Manning equation and critical depth from Q²T/(gA³) = 1 for trapezoidal, rectangular and circular sections. When a channel lining is selected, the calculation core checks the velocity against the limits of Taiwan Soil and Water Conservation Technical Regulations Art. 85.
Manning Uniform Flow & Critical Depth Q²T/(gA³) = 1velocity limits (when a lining is selected) per Taiwan Soil and Water Conservation Technical Regulations Art. 85
Solves the required pipe diameter or channel bottom width with the Manning equation, rounds it up to the increment you enter and reports the normal depth and velocity of the adopted size. The default pipe depth ratio and the freeboard note follow Taiwan Soil and Water Conservation Technical Regulations Arts. 87 and 86, as reported by the calculation core.
Manning Uniform Flow Bisection Sizingdefault pipe depth ratio and freeboard note per Taiwan Soil and Water Conservation Technical Regulations Arts. 87 and 86
Inlet-control headwater by the HY-8 polynomial or the HDS-5 equations and outlet-control headwater by the energy equation, per FHWA HDS-5 (3rd Ed., 2012) and HY-8 v7.5. The calculation core checks the headwater elevation against the allowable level you enter.
FHWA HDS-5 Hydraulic Design of Highway Culverts (3rd Ed., 2012)HY-8 v7.5 Energy FormulationsMOTC (Taiwan) Highway Drainage Design Code (2018) 6.2.1 items 1 and 3
Basis: Orifice Q = Cd·A·√(2gH) and Sharp/Broad-Crested Rectangular Weir Q = Cw·L·H^1.5. Verification cases, tolerances and actual differences for the calculation core are listed on the Benchmarks page.
Outlet sizing with the orifice equation Q = Cd·A·√(2gH) and the rectangular weir equation Q = Cw·L·H^1.5. The calculation core rounds the size down to the entered increment and reports the actual outflow of the adopted size.
On-grade and sag inlet hydraulics per FHWA HEC-22 Chapter 4 and the US EPA SWMM 5.2 inlet module, for grate, kerb-opening and combination inlets with a gutter depression and a clogging reduction factor.
Pre- and post-development peak flows by the Rational Method and the required storage from a triangular hydrograph, with a 10% allowance on the design storage. Design rainfall intensities are entered directly; a DID Malaysia MSMA 2nd Edition (2012) Equation 2.2 IDF mode can be selected instead.
Rational Method & Triangular Hydrograph On-Site Detention Sizing (Custom IDF)DID Malaysia (JPS), Urban Stormwater Management Manual for Malaysia (MSMA) — selectable IDF mode
Basis: MOTC (Taiwan) Highway Drainage Design Code §5.13 Eq. 5-3 (stone size and apron dimensions) and FHWA HEC-23 Vol. 1 Eq. 5.1 (Isbash D50, for reference). Verification cases, tolerances and actual differences for the calculation core are listed on the Benchmarks page.
Stone size d = V²/24.7 and minimum apron width and length per MOTC (Taiwan) Highway Drainage Design Code §5.13 Eq. 5-3, with the FHWA HEC-23 Vol. 1 Eq. 5.1 (Isbash) median stone size D50 listed for reference.
Empirical plunge-pool scour formulas compiled in Taiwan Soil and Water Conservation Bureau technical series No. 04, §4.6 Tables 4-9 and 4-10, evaluated side by side with the envelope maximum.
Empirical Jet Plunge Scour Formulas (Schoklitsch, Veronese, Mason & Arumugam, Martins, Jaeger)Taiwan Soil and Water Conservation Bureau technical series No. 04, §4.6 Tables 4-9 and 4-10
Spillway and downstream apron proportioning per Taiwan Soil and Water Conservation Handbook (2017) §2.1 and Taiwan Soil and Water Conservation Technical Regulations Art. 65, as reported by the calculation core. Dam-body stability is not part of this online calculator.
Taiwan Soil and Water Conservation Handbook (2017) §2.1 Eqs. 2.1.2–2.1.4, 2.1.46–2.1.50 (trapezoidal spillway, freeboard, apron)Taiwan Soil and Water Conservation Technical Regulations Art. 65
Geometric and hydraulic proportioning of vertical channel drops and stilling basins per Taiwan Soil and Water Conservation Handbook (2017) §2.20 Drop Structures, as reported by the calculation core, which also checks the drop height against 3 m.
Taiwan Soil and Water Conservation Handbook (2017) §2.20 Drop Structures (apron and stilling basin length, sills, wingwalls, RC thickness)
Manning uniform flow on the reaches between drops, with the maximum permissible velocity taken from Taiwan Soil and Water Conservation Technical Regulations Art. 85 for the selected lining or entered by the user, and the drop layout per the Taiwan Soil and Water Conservation Handbook §2.20.
Manning Uniform Flowmaximum permissible velocity per Taiwan Soil and Water Conservation Technical Regulations Art. 85drop layout per Taiwan Soil and Water Conservation Handbook, Engineering Part §2.20
Basis: Meyerhof (1963) general bearing capacity equation with Vesić (1973) Nγ, Hansen (1970) depth factors and Meyerhof inclination factors and required factor of safety defaults to Taiwan Soil and Water Conservation Technical Regulations Art. 120, item 3. Verification cases, tolerances and actual differences for the calculation core are listed on the Benchmarks page.
Step-by-step bearing capacity with eccentric and inclined loads using the Meyerhof (1963) general bearing capacity equation with the Vesić (1973) Nγ factor, Hansen (1970) depth factors and Meyerhof inclination factors. The required factor of safety is an input whose default of 3 follows Taiwan Soil and Water Conservation Technical Regulations Art. 120, item 3. A Eurocode 7 partial-factor verification is not part of this calculator's output.
Meyerhof (1963) general bearing capacity equation with Vesić (1973) Nγ, Hansen (1970) depth factors and Meyerhof inclination factorsrequired factor of safety defaults to Taiwan Soil and Water Conservation Technical Regulations Art. 120, item 3
Time-stepping wetting-front advance by Green–Ampt (US EPA SWMM Vol. I §4.4.1) or the Lumb (1975) wetting band, with the infinite-slope factor of safety at each step. The required factor of safety follows Taiwan Soil and Water Conservation Technical Regulations Art. 73 (rainstorm condition), as reported by the calculation core.
US EPA SWMM Vol. I §4.4.1 (Green–Ampt)Lumb (1975) / HK GEO Manual §4.4.3Pradel & Raad (1993)
Closed-form elastic subgrade reaction solution (Chang 1937) for fixed-head and free-head piles. The subgrade modulus kH and the allowable pile-head deflection follow the Taiwan Building Foundation Design Code (2023) commentary and the MOTC (Taiwan) Seismic Design Code for Highway Bridges Eq. C4-21, as reported by the calculation core, which also checks the long-pile criterion β·L ≥ 3.
Chang (1937) Elastic Subgrade Reaction Beam-on-Winkler-Foundation Analytical Solutionsubgrade modulus and allowable head displacement per Taiwan Building Foundation Design Code (2023) commentary and MOTC (Taiwan) Seismic Design Code for Highway Bridges Eq. C4-21Taiwan Building Foundation Design Code, Commentary p. 5-41
ULS sliding and bearing checks and a base eccentricity check under EN 1997-1:2004 Design Approach 1 by default. The design-code selector also offers the UK and Singapore National Annexes, DA2, 2nd-Gen EN 1997-1:2024 / EN 1997-3:2025 (MFA or RFA), HK GEO Geoguide 1 and AASHTO LRFD / FHWA ASD options, and γG, γQ and γφ' can be overridden for a National Annex. When concrete and steel strengths are entered, an RC flexural and shear design table for metric H-bars is added.
EN 1997-1:2004 Design Approach 1 (DA1 Comb. 1 & Comb. 2) — defaultBS EN 1997-1:2004 + UK National Annex — selectableSS EN 1997-1:2010 + Singapore National Annex — selectable
Circular slip-surface search by Bishop's simplified method (or the Fellenius method) for a homogeneous slope with a water table, with the slice table printed and the EN 1997-1:2004 §11 Design Approach 1 ratios Rd/Ed checked by default. The selector also offers the UK National Annex, DA3, 2nd-Gen EN 1997-1:2024 / EN 1997-3:2025 Clause 4 (MFA, VC3 + M2) and USACE EM 1110-2-1902 options.
Circular Slip Slope Stability (Bishop Simplified)EN 1997-1:2004 §11 Design Approach 1 (Comb. 1 & Comb. 2) — defaultBS EN 1997-1:2004 + UK NA — selectable
Simplified SPT procedure of NCEER / Youd et al. (2001), with EN 1998-5 Annex B in the basis stated by the calculation core. The JRA, AIJ and HBF factors of safety are listed alongside, and the check row compares the NCEER FS_liq with 1.00.
NCEER / Youd et al. (2001) Simplified SPT Liquefaction ProcedureEN 1998-5 Annex BYoud et al. (2001) JGGE & EN 1998-5 §4.1.4
Basis: ISO 80000-4 / NIST SP 811 Exact Conversion Factors. Verification cases, tolerances and actual differences for the calculation core are listed on the Benchmarks page.
Unit conversion with exact factors (gn = 9.80665 m/s², 1 ft = 0.3048 m, 1 lbf = 4.4482216 N), for checking older kgf-based reports (kgf/cm², tf/m²) against SI calculations (kPa, MPa, kN/m) and US units.
ISO 80000-4 / NIST SP 811 Exact Conversion Factors
Pier backwater (Yarnell), flow-area obstruction ratio, low-chord freeboard, contraction scour (live-bed and clear-water), local pier scour (with skew and woody-debris equivalent pier width), maximum probable scour depth, stream pressure on piers and riprap at piers.
Loads on single- and multi-cell reinforced concrete box culverts (fill, two lateral earth pressure cases, HS20-44 distributed through fill, internal water, groundwater), closed-frame force envelopes, reinforcement, crack control and flotation.
MOTC (Taiwan) Highway Bridge Design Code, load factor design with HS20-44; direct stiffness closed-frame analysis
Overall flotation of buried detention / sediment basins, reservoirs and U-shaped open channels (with quantified options when insufficient), two-face reinforcement of walls and base slab, and crack control for liquid tightness (code bar spacing, crack width or steel stress limit).
Taiwan Design Code for Concrete Structures (2023) Arts. 5.3.6, 5.3.7, 7.6.1.1, 22.5, 24.3.2; flotation per Taiwan Building Foundation Design Code Art. 2.12; optional direct crack width per EN 1992-1-1 7.3.4 / EN 1992-3 7.3.1 (not ACI 350)
Flexure and one-way shear (with size effect) of the face slab horizontal strip and the heel slab longitudinal strip, sloping-face tension steel of the counterforts, and concrete volume.
Taiwan Design Code for Concrete Structures (2023; ACI 318-19 framework) Tables 6.5.2, 6.5.4, 22.5.5.1; Taiwan Soil and Water Conservation Technical Regulations Arts. 119, 120 (strip method)
Staged excavation of a strutted diaphragm wall on elasto-plastic soil springs with preloaded struts: wall deflection, bending moment and shear envelopes, and the flexural and shear resistance of the wall reinforcement.
Taiwan Building Foundation Design Code (2023) commentary 8.7.3, Fig. C8.7-5 elasto-plastic subgrade reaction method; Taiwan Design Code for Concrete Structures (2023; ACI 318-19 framework) Chs. 21, 22
Pile reactions of a rigid cap, moments at the column face and two-way bottom reinforcement, one-way shear, two-way shear around the column (including moment transfer), punching by a single pile, and bar development.
Slope, flow velocity and full-flow capacity of a storm sewer reach, hydraulic grade line (HGL) at the manholes with an optional downstream water level, minimum cover, manhole spacing, and vertical clearance to a crossing utility.
Taiwan Sewerage Engineering Facility Standards (amended 2025-11-04) Arts. 3-8; Manning flow and hydraulic grade line by the design-table method
Stopping sight distance, minimum horizontal curve radius, minimum transition curve length, maximum grade and crest / sag vertical curve length for the selected design speed, checked against either the allowable or the recommended values of the code.
Required structural number SN from the design ESAL W18, reliability R, overall standard deviation S0, initial and terminal serviceability p0 and pt, and subgrade resilient modulus MR, checked against the SN provided by the layer thicknesses (with the SN of each layer tabulated).
AASHTO Guide for Design of Pavement Structures (1993) / FHWA NHI-05-037 Appendix C Eqs. C.2, C.3, Table C-3
Three temporary works checks selected by type: steel tube formwork shoring posts (slenderness and axial capacity), braced excavation struts and walers under apparent earth pressure, and scaffold post buckling with wall tie force under wind and wall tie spacing limits.
MOTC (Taiwan) Highway Construction Specifications (2013-01) Sec. 01525, 2.3; post allowable axial force per MOTC (Taiwan) Highway Bridge Design Code (2009 provisions) Ch. 9 allowable stress design scaled to a safety factor of 2.5; Taiwan Standards for Construction Safety and Health Facilities Art. 131
EN 1997-1:2004 DA1 (Comb. 1 & 2), UK NA, DA2 (walls) / DA3 (slopes), 2nd-Gen EN 1997-1:2024 / EN 1997-3:2025 (MFA; RFA for walls); RC design table for metric H-bars (walls)
No UK-specific hydraulic method is built in; each hydraulic calculator states its basis (e.g. Manning, FHWA HEC-22, FHWA HDS-5)
WGS 84 / UTM zones
Singapore & Malaysia
SS EN 1997-1:2010 + Singapore NA (retaining walls)
DID Malaysia MSMA 2nd Edition (2012) Eq. 2.2 IDF mode in the detention calculator
WGS 84 / UTM zones
Hong Kong SAR
HK GEO Geoguide 1 (Tables 6 & 7 ULS + §9.2.4 SLS) for retaining walls; Lumb (1975) wetting-band option in the rainfall slope calculator
No Hong Kong-specific hydraulic method is built in
WGS 84 / UTM zones
Australia & New Zealand
Eurocode 7 options as above; NCEER (Youd et al., 2001) liquefaction triggering
Design intensities entered directly (no ARR 2019 IFD data built in)
GDA2020 / MGA2020 zones 46–59; WGS 84 / UTM zones
Frequently Asked Questions
Design codes, Hong Kong positioning, data sources and purchasing are answered below. Previews are calculated in your browser (WebAssembly) and your inputs are not sent anywhere. Only when you click Formal export are that export's inputs sent over HTTPS to the licence server, which builds the file in memory without writing it to disk or logging your values. The verification cases of the calculation core are summarised on the Benchmarks page.
Which design codes are offered across these calculators?
The retaining wall calculator offers EN 1997-1:2004 Design Approach 1 (default), the UK and Singapore National Annexes, DA2, 2nd-Gen EN 1997-1:2024 / EN 1997-3:2025 (MFA and RFA), HK GEO Geoguide 1 and AASHTO LRFD / FHWA ASD options, and designs metric H-bars (H10–H32) when concrete and steel strengths are entered. The slope stability calculator offers EN 1997-1:2004 §11 Design Approach 1 (default), the UK National Annex, DA3, 2nd-Gen MFA (VC3 + M2) and USACE EM 1110-2-1902. The liquefaction calculator reports the NCEER (Youd et al., 2001) factor of safety with EN 1998-5 Annex B in its stated basis, and the detention calculator offers a DID Malaysia MSMA 2nd Edition (2012) IDF mode. Several hydraulic and geotechnical calculators apply Taiwan regulations for their thresholds, for example the permissible velocities of Taiwan Soil and Water Conservation Technical Regulations Art. 85. Each page states its design basis exactly as the calculation core reports it.
Is HyGeoWorks on the Hong Kong Buildings Department list of pre-accepted programs?
HyGeoWorks does not claim Buildings Department pre-accepted program status. For Hong Kong retaining walls, the Geoguide 1 option applies the Table 6 and Table 7 partial factors at ULS and the §9.2.4 middle-third eccentricity check at SLS, and the page shows the calculation core's steps and checks so that the result can be checked independently. The free online result is a preview, not for formal submission; licensed users can formally export a single-tool Word report online, and the HydroStudio desktop edition writes whole-project calculation reports.
Which data set does the carbon calculator use, and are commercial databases included?
The carbon calculator estimates upfront emissions in three stages only: materials (A1–A3), transport (A4) and site construction (A5). It is a screening estimate, not a whole-life assessment, and it does not verify EPDs. Its basis line cites PAS 2080:2023 and the UK DESNZ Greenhouse Gas Reporting Conversion Factors, which contain public sector information licensed under the Open Government Licence v3.0; the library's entries for diesel combustion, HGV freight and primary metals do not match the 2026 edition (see the open carbon factors reference chart), so check each factor against the edition your project requires. No commercial or restricted database is redistributed.
How do pricing and invoicing work?
Desktop licences are priced in US dollars: Pro (all modules) is US$990/yr or US$119/month, and a single-discipline annual licence is US$590/yr; 30- and 90-day passes and firm plans are listed in the pricing section. The licence server produces a printable USD commercial quotation (print or save as PDF). Checkout is handled by Stripe, where a tax ID can be entered; for one-time payments Stripe issues an invoice showing the buyer's name and tax ID. Purchasing approval follows your organisation's own rules.
Previews run in your browser; inputs are sent only when you formally export. Online previews are not for formal submission.
From the Online Preview to the HydroStudio Desktop Edition
The free preview has no Word report, DXF drawing or verification code. Licensed users can sign in on the calculator and formally export a single-tool Word report (with a verification code) and DXF drawing, or combine several calculators in the Project List and export a multi-chapter project report online; projects with terrain or GIS files can run in the heavy cloud computation, and interactive 2D models and large simulations use the desktop edition. Export a .toml project file from the calculator and open it in the HydroStudio desktop edition (Windows 10/11, 64-bit); fields that the online tool does not cover are marked as placeholders and must be completed there before calculating. With a licence, the desktop edition writes Word (.docx) calculation reports, Excel (.xlsx) workbooks with live formulas and .dxf drawings without the trial watermark, and also includes 2D shallow-water flood modelling (Godunov finite volume) and 2D finite-element variably saturated seepage.
$990 USD / yr — Pro (all modules), annual
Pro monthly: $119 USD/month · Single discipline: $590 USD/yr · 30-day single-discipline pass: $79 USD · Printable USD quotation · Checkout via Stripe.