Check Summary Preview (Software Format; Auto-Populated)
| Check item | Trial value | Status |
|---|---|---|
| Mild-Reach Flow Velocity | 3.476 m/s ≤ 3.5 m/s | OK |
Summary of the online calculation (software format) for checking by the designer and an independent checker. Final sign-off remains the responsibility of the chartered or registered engineer.
Desktop edition: calculation reports and cross-module quantity reconciliation
1. Calculation reports: with a licence, the desktop edition writes Word (.docx) and Excel (.xlsx) calculation reports and DXF drawings without the trial watermark, listing the inputs, the equations used and the results; in trial mode the step-by-step detail is hidden. For this calculator alone, licensed users can also sign in on the calculator above and formally export a single-tool Word report (with a verification code) and DXF drawing. The Pro plan (all modules) is US$990 per year; see Pricing for monthly, perpetual and team plans.
2. Cross-module reconciliation: desktop project runs carry the design peak flow into downstream channel, culvert and bridge hydraulics; terrain cut/fill into the earthwork balance, cost and carbon tables; structural concrete, formwork and rebar take-off into the cost and carbon tables; slope and excavation safety-factor thresholds into construction monitoring trigger levels.
3. Independent checking engineers, authority reviewers and academics can request a complimentary review or teaching licence (link below).
1. Governing Equations & SI Nomenclature
The equations the calculation core applies are summarised below for independent checking.
The equations below summarise the method that the calculation core applies on this page. The design basis it reports is: Manning Uniform Flow; maximum permissible velocity per Taiwan Soil and Water Conservation Technical Regulations Art. 85; drop layout per Taiwan Soil and Water Conservation Handbook, Engineering Part §2.20. The worked example further down lists the core's own calculation steps for the standard example.
2. Worked Standard Example (Computed by the Calculation Core)
The worked example below was computed by the calculation core when this page was built; entering the same inputs above reproduces it.
Design Scenario — 0.80 m Rectangular Drain on a 20% Slope (Q = 1.00 m³/s, V_max = 3.5 m/s): Lay out drops at 6.0 m spacing over a 36 m reach of a 0.80 m wide rectangular concrete drain (n = 0.015) on a 20% ground slope carrying 1.00 m³/s, where the velocity on the unstepped slope exceeds the user-specified permissible velocity of 3.5 m/s.
The inputs below were passed to the calculation core (WebAssembly) when this page was built; every step, result and check shown here is the core's own output. Basis reported by the core: Manning Uniform Flow; maximum permissible velocity per Taiwan Soil and Water Conservation Technical Regulations Art. 85; drop layout per Taiwan Soil and Water Conservation Handbook, Engineering Part §2.20
Inputs Passed to the Calculation Core
| Parameter | Value | Unit |
|---|---|---|
| Cross-Section Shape | Rectangular | — |
| Bottom Width b | 0.8 | m |
| Manning n | 0.015 | — |
| Existing Ground Slope S0 | 0.2 | m/m |
| Design Discharge Q | 1 | m³/s |
| Channel Lining Material | Custom maximum permissible velocity | — |
| Maximum Permissible Velocity | 3.5 | m/s |
| Perennial Flow | No | — |
| Drop Spacing s | 6 | m |
| Channel Reach Length L | 36 | m |
Calculation Steps (calculation core output)
[HyGeoWorks online preview - not for PE sealing or submittal]
- Section: Rectangular b = 0.800 m; n = 0.015, Q = 1 m³/s; Max. Permissible Velocity Vmax = 3.5 m/s (User-specified)
- Natural slope S0 = 0.2: V = 7.266 m/s > Vmax (drop cascade required)
- Mild-reach slope: solve Sb for V(Sb) = Vmax -> unit drop height H = ceil_cm((S0 - Sb)*s) = 1.05 m
- Sb = S0 − H/s = 0.2 − 1.05/6 = 0.02500; mild-reach yn = 0.3596 m, V = 3.476 m/s
- Drop count = ceil(channel length / spacing) = 6
Computed Results (calculation core output)
| Output Parameter | Calculated Value | SI Unit |
|---|---|---|
| Number of Drops | 6 | units |
| Unchecked Ground-Slope Velocity | 7.266 | m/s |
| Mild-Reach Bed Slope Sb | 0.02500 | m/m |
| Unit Drop Height H | 1.05 | m |
| Mild-Reach Normal Depth yn | 0.3596 | m |
| Mild-Reach Velocity V | 3.476 | m/s |
Verification Checks (calculation core output)
| Verification Check | Computed Value | Criterion | Verdict | Basis |
|---|---|---|---|---|
| Mild-Reach Flow Velocity | 3.476 m/s | ≤ 3.5 m/s | OK | User-specified |
Assumptions and Limits Stated by the Calculation Core
- Size individual stilling basins using the Hydraulic Drop Structure tool (H = 1.05 m)
3. Regional Design Options in This Edition: UK, EU, Singapore, Malaysia, Hong Kong & Australia
Symbols and units are SI unless stated otherwise.
- This calculator: the design basis is the one reported by the calculation core: Manning Uniform Flow; maximum permissible velocity per Taiwan Soil and Water Conservation Technical Regulations Art. 85; drop layout per Taiwan Soil and Water Conservation Handbook, Engineering Part §2.20. The options listed below belong to the calculators named in each item.
- United Kingdom, Ireland & European Union: The retaining wall and slope stability calculators default to EN 1997-1:2004 Design Approach 1 (Combination 1 & Combination 2); the UK National Annex and 2nd-Gen EN 1997-1:2024 / EN 1997-3:2025 (MFA, and RFA for retaining walls) are selectable there, as are DA2 for retaining walls and DA3 for slopes. The retaining wall calculator lets γG, γQ and γφ' be overridden for a National Annex and designs metric H-bars (H10–H32) when concrete and steel strengths are entered.
- Singapore & Malaysia: The retaining wall calculator offers SS EN 1997-1:2010 with the Singapore National Annex, and the detention calculator offers a DID Malaysia MSMA 2nd Edition (2012) Equation 2.2 IDF rainfall mode besides directly entered design intensities.
- Hong Kong SAR: HyGeoWorks does not claim Hong Kong Buildings Department pre-accepted program status; the retaining wall calculator's HK GEO Geoguide 1 option shows the calculation core's steps and checks so that the result can be checked independently. With that option the calculation core applies the Geoguide 1 Table 6 and Table 7 partial factors at ULS and the §9.2.4 middle-third eccentricity check at SLS.
- Australia & New Zealand: No ARR 2019 IFD data is built in; design rainfall intensities for any AEP can be entered directly in the detention calculator. The HydroStudio desktop edition supports GDA2020 / MGA2020 zones 46–59 as well as WGS 84 / UTM zones.
4. Frequently Asked Questions
Common questions about this calculator are answered below. Final sign-off remains the responsibility of the chartered or registered engineer.
What happens if a steep drain is built without drops?
On a steep slope the flow accelerates well beyond the permissible velocity for the lining, which abrades the lining, can make the flow overtop the channel walls and scours the toe. The calculation core reports the velocity on the unstepped slope beside the mild-reach velocity so the effect of the drops is visible.
Which permissible velocity is used?
If a lining material is selected, the maximum permissible velocity is taken from Taiwan Soil and Water Conservation Technical Regulations Art. 85; with the custom option, as in the example on this page, the value you enter is used and the check basis reads "User-specified".
Does the calculator add freeboard for air entrainment?
No. It computes the normal depth and velocity of the mild reaches between drops. Freeboard and splash protection at the drops are set by the designer according to the applicable rules.
How do I size the basin at each drop?
Enter the drop height reported on this page and the design discharge into the Drop Structure calculator (/en/tools/drop-structure/), as the calculation core's note suggests, to size the stilling basin, sills and wingwalls of each drop.
5. Explore All 30 Calculators (SI Edition; Design Basis Stated on Each Page)
Each calculator below states its own design basis on its page; several apply Taiwan regulations and say so.