Drainage Reference Notes for England: National SuDS Standards Discharge Limits and Environment Agency Peak Rainfall Allowances
This page quotes two official sources for surface water drainage design in England: Defra's National standards for sustainable drainage systems (first published 19 June 2025) and the Environment Agency guidance on climate change allowances for flood risk assessments (last updated 27 May 2022). The platform's code library holds no Manning roughness table for UK practice, so none is given here; roughness is a user input in the online tools.
Reference table
| Topic | Requirement or rule | Source |
|---|---|---|
| Peak discharge for the 50% AEP event | Limited to the equivalent 50% AEP greenfield runoff rate, or 3 l/s/ha, whichever is the greater | National standards for SuDS (Defra, 2025), paragraph 3.18 |
| Peak discharge for the 1% AEP event where the 6-hour runoff volume is greater than the greenfield volume | Limited to the 50% AEP greenfield runoff rate or 3 l/s/ha, whichever is the greater | National standards for SuDS, paragraph 3.19 |
| Peak discharge for the 1% AEP event where the runoff volume is less than or equivalent to the greenfield volume | Limited to the 1% AEP greenfield runoff rate or 3 l/s/ha, whichever is the greater | National standards for SuDS, paragraph 3.20 |
| Previously developed sites | Any relaxation factor shall be no greater than 5 times the greenfield runoff rate | National standards for SuDS, paragraph 3.21.1 |
| Greenfield rate equivalence | The 50% AEP greenfield runoff rate can be considered equivalent to the calculated QBAR (mean annual flood) or QMED (median annual flood) for the site | National standards for SuDS, paragraph 3.27 |
| Climate change allowance within the SuDS standards | The Upper End Allowance shall be used for the relevant epoch based on the design lifetime of the proposed development | National standards for SuDS, paragraph 3.8 |
| How peak rainfall allowances are published | By management catchment, for 1% and 3.3% annual exceedance probability events, for the 2050s (2022 to 2060) and 2070s (2061 to 2125) epochs, as central and upper end values | Environment Agency, Flood risk assessments: climate change allowances |
Notes and Conditions of Use
- The allowance percentages are published on the Environment Agency map and in its table of peak rainfall allowances by management catchment; look up the value for the site. No single national percentage applies.
- The 2025 national standards replace the non-statutory technical standards published in March 2015.
- The detention calculator takes the design rainfall intensity as an input and contains no UK rainfall data.
Frequently Asked Questions
Is a national rainfall uplift of +20% to +40% still current?
No. Since 10 May 2022 the Environment Agency has provided peak rainfall allowances by management catchment instead of at a national scale, for 1% and 3.3% annual exceedance probability events and for two epochs rather than three.
What minimum discharge rate do the 2025 standards state?
The figure of 3 l/s/ha appears as the alternative limit in paragraphs 3.18 to 3.20: the greenfield runoff rate or 3 l/s/ha, whichever is the greater. Requirements of the approving body for a particular site may differ and should be confirmed.
Sources and disclaimer: values on these pages come from the platform's code-constants library, from producers' published section tables, or from the official publications named in each row. Rows that cite the UK Government GHG Conversion Factors contain public sector information licensed under the Open Government Licence v3.0. Standards (EN, BS) are cited by number only and their text is not reproduced. These pages are a design aid, not an official document; check the current source before use. Calculations must be checked and approved by a suitably qualified engineer.