Selected UKC and UKB Section Properties (Blue Book) and Steel Sheet Pile Properties per Metre of Wall

Properties of four universal column and beam sections as printed in the Steel for Life / SCI Blue Book (Eurocode 3 with the UK National Annex, BS EN 10365:2017), and of two ArcelorMittal sheet pile sections per metre of wall from the producer's published tables. These sections are not in the platform's code library: the linked temporary works calculator uses CNS 1490 H-shapes and Taiwan specifications.

Reference table

→ Open the temporary works calculator (reference calculation to Taiwan specifications)

SectionMassAreaSecond moment of areaElastic section modulusMinor-axis radius of gyrationSource
254 x 254 x 89 UKC88.9 kg/m113 cm²Iy = 14,300 cm⁴Wel,y = 1,100 cm³iz = 6.55 cmBlue Book
305 x 305 x 137 UKC136.9 kg/m174 cm²Iy = 32,800 cm⁴Wel,y = 2,050 cm³iz = 7.83 cmBlue Book
356 x 406 x 235 UKC235.1 kg/m299 cm²Iy = 79,100 cm⁴Wel,y = 4,150 cm³iz = 10.2 cmBlue Book
533 x 210 x 92 UKB92.1 kg/m117 cm²Iy = 55,200 cm⁴Wel,y = 2,070 cm³iz = 4.51 cmBlue Book
PU 18 sheet pile (per m of wall)128.2 kg/m²163.3 cm²/m38,650 cm⁴/m1,800 cm³/mNot applicableArcelorMittal
AZ 26 sheet pile (per m of wall)155.2 kg/m²197.8 cm²/m55,510 cm⁴/m2,600 cm³/mNot applicableArcelorMittal

Notes and Conditions of Use

  • Blue Book values are given to the three significant figures printed there.
  • PU 18 and PU 18-1 are different sections: the producer lists PU 18-1 at 35,950 cm⁴/m and 1,670 cm³/m. Check the exact designation before use.
  • The Construction (Design and Management) Regulations 2015, regulation 19(2), require that any buttress, temporary support or temporary structure be of such design and installed and maintained so as to withstand any foreseeable loads which may be imposed on it, and be used only for the purposes for which it was designed, installed and maintained.
  • For ultimate limit state design of embedded walls with normal site control, Eurocode 7 increases the retained height by an unplanned excavation allowance: 10% of the retained height for cantilever walls, or 10% of the height below the lowest support for supported walls, up to a maximum of 0.5 m (as summarised in JRC report EUR 26227 EN, 2013, Table 7.2.4).

Frequently Asked Questions

Does this site check steel props or walings to Eurocode 3?

No. The temporary works calculator performs the checks listed on its page using Taiwan specifications and CNS 1490 H-shape properties. The UK sections above are listed for reference and cannot be selected in that tool.

Where do the sheet pile values come from?

From ArcelorMittal's published section tables, per metre of wall: PU 18 at 163.3 cm²/m, 128.2 kg/m², 38,650 cm⁴/m and 1,800 cm³/m; AZ 26 at 197.8 cm²/m, 155.2 kg/m², 55,510 cm⁴/m and 2,600 cm³/m. Confirm against the producer's current documentation before ordering or detailing.