Selected HP and W Shape Properties and PZ Sheet Pile Properties per Foot of Wall, with OSHA Subpart P Engineer-Design Provisions
Section properties of four rolled shapes and two hot-rolled Z sheet piles as printed in the producers' published tables (Nucor-Yamato structural shapes catalog, April 2023, and the Nucor Skyline PZ data sheet). These shapes are not part of the platform's code library: the linked temporary works calculator uses CNS 1490 H-shapes and Taiwan specifications in SI units.
Reference chart
| Section | Weight | Area | Moment of inertia Ix | Elastic section modulus Sx | Weak-axis radius of gyration ry | Source |
|---|---|---|---|---|---|---|
| HP12x53 | 53 lb/ft | 15.5 in² | 393 in⁴ | 66.7 in³ | 2.86 in. | Nucor-Yamato catalog |
| HP14x73 | 73 lb/ft | 21.4 in² | 729 in⁴ | 107 in³ | 3.49 in. | Nucor-Yamato catalog |
| HP14x117 | 117 lb/ft | 34.4 in² | 1,220 in⁴ | 172 in³ | 3.59 in. | Nucor-Yamato catalog |
| W14x90 | 90 lb/ft | 26.5 in² | 999 in⁴ | 143 in³ | 3.70 in. | Nucor-Yamato catalog |
| PZ22 sheet pile (per ft of wall) | 22.0 lb/ft² of wall | 6.47 in²/ft | 84.38 in⁴/ft | 18.1 in³/ft | Not applicable | Nucor Skyline data sheet |
| PZ27 sheet pile (per ft of wall) | 27.0 lb/ft² of wall | 7.94 in²/ft | 184.20 in⁴/ft | 30.2 in³/ft | Not applicable | Nucor Skyline data sheet |
Notes and Limits of Applicability
- 29 CFR 1926.652(c)(4)(i): support systems, shield systems and other protective systems not utilizing Option 1, Option 2 or Option 3 of paragraph (c) shall be approved by a registered professional engineer. Paragraph (c)(4)(iii) requires at least one copy of the design to be maintained at the jobsite during construction of the protective system.
- The 20-ft depth figure is found in the appendices to Subpart P rather than in 1926.652 itself. Appendix F states that protective systems for use in excavations more than 20 feet in depth must be designed by a registered professional engineer in accordance with 1926.652(b) and (c); Appendix B, Table B-1, Note 3 says the same of sloping or benching for excavations greater than 20 feet deep.
- Scaffolds: 29 CFR 1926.452(b)(10) for tube and coupler scaffolds and 1926.452(c)(6) for fabricated frame scaffolds require scaffolds over 125 feet in height to be designed by a registered professional engineer; 1926.452(a)(10) sets 60 feet for pole scaffolds.
Frequently Asked Questions
Does the linked calculator check OSHA compliance or AISC member capacity?
No. It is a reference calculation that follows the Taiwan specifications named on its page and uses CNS 1490 H-shape properties in SI units. The US shapes charted here are for reference and cannot be selected in that tool.
Where do the PZ sheet pile figures come from?
From the producer's data: PZ22 at 6.47 in²/ft, 22.0 lb/ft² of wall, 84.38 in⁴/ft and 18.1 in³/ft; PZ27 at 7.94 in²/ft, 27.0 lb/ft² of wall, 184.20 in⁴/ft and 30.2 in³/ft. Confirm against the supplier's current data before ordering or detailing.
Sources and disclaimer: figures on these charts are drawn from the platform's code-constants library, from steel producers' published section data, or from the U.S. Government publications named beside each entry (FHWA, USDA, OSHA, FEMA, EPA and GSA). Naming a publication does not imply endorsement by any agency. Consensus standards (ACI, ASTM, AASHTO, AISC) are identified by designation only and none of their text is reproduced. The charts are a design aid rather than an official document, so confirm each figure against the current source. Engineering submittals remain the responsibility of the licensed professional engineer who seals them.