Selected HP and W Shape Properties and PZ Sheet Pile Properties per Foot of Wall, with OSHA Subpart P Engineer-Design Provisions

Section properties of four rolled shapes and two hot-rolled Z sheet piles as printed in the producers' published tables (Nucor-Yamato structural shapes catalog, April 2023, and the Nucor Skyline PZ data sheet). These shapes are not part of the platform's code library: the linked temporary works calculator uses CNS 1490 H-shapes and Taiwan specifications in SI units.

Reference chart

→ Open the temporary works calculator (Taiwan-specification reference calculation in SI units; not an OSHA compliance check)

SectionWeightAreaMoment of inertia IxElastic section modulus SxWeak-axis radius of gyration rySource
HP12x5353 lb/ft15.5 in²393 in⁴66.7 in³2.86 in.Nucor-Yamato catalog
HP14x7373 lb/ft21.4 in²729 in⁴107 in³3.49 in.Nucor-Yamato catalog
HP14x117117 lb/ft34.4 in²1,220 in⁴172 in³3.59 in.Nucor-Yamato catalog
W14x9090 lb/ft26.5 in²999 in⁴143 in³3.70 in.Nucor-Yamato catalog
PZ22 sheet pile (per ft of wall)22.0 lb/ft² of wall6.47 in²/ft84.38 in⁴/ft18.1 in³/ftNot applicableNucor Skyline data sheet
PZ27 sheet pile (per ft of wall)27.0 lb/ft² of wall7.94 in²/ft184.20 in⁴/ft30.2 in³/ftNot applicableNucor Skyline data sheet

Notes and Limits of Applicability

  • 29 CFR 1926.652(c)(4)(i): support systems, shield systems and other protective systems not utilizing Option 1, Option 2 or Option 3 of paragraph (c) shall be approved by a registered professional engineer. Paragraph (c)(4)(iii) requires at least one copy of the design to be maintained at the jobsite during construction of the protective system.
  • The 20-ft depth figure is found in the appendices to Subpart P rather than in 1926.652 itself. Appendix F states that protective systems for use in excavations more than 20 feet in depth must be designed by a registered professional engineer in accordance with 1926.652(b) and (c); Appendix B, Table B-1, Note 3 says the same of sloping or benching for excavations greater than 20 feet deep.
  • Scaffolds: 29 CFR 1926.452(b)(10) for tube and coupler scaffolds and 1926.452(c)(6) for fabricated frame scaffolds require scaffolds over 125 feet in height to be designed by a registered professional engineer; 1926.452(a)(10) sets 60 feet for pole scaffolds.

Frequently Asked Questions

Does the linked calculator check OSHA compliance or AISC member capacity?

No. It is a reference calculation that follows the Taiwan specifications named on its page and uses CNS 1490 H-shape properties in SI units. The US shapes charted here are for reference and cannot be selected in that tool.

Where do the PZ sheet pile figures come from?

From the producer's data: PZ22 at 6.47 in²/ft, 22.0 lb/ft² of wall, 84.38 in⁴/ft and 18.1 in³/ft; PZ27 at 7.94 in²/ft, 27.0 lb/ft² of wall, 184.20 in⁴/ft and 30.2 in³/ft. Confirm against the supplier's current data before ordering or detailing.