Metric Ribbed Reinforcement Table (H10 to H40, B500B): Bar Area, Mass per Metre and Area per Metre Width
Nominal diameters, bar areas and masses are the values held in the platform's code-constants library for BS 4449:2005+A3:2016 Grade B500B bars (fyk = 500 MPa), the same constants used by the online tools. Area per metre width is the bar area divided by the bar spacing, rounded to the nearest mm²/m.
Reference table
| Bar | Nominal diameter (mm) | Bar area (mm²) | Mass (kg/m) | As at 100 mm spacing (mm²/m) | As at 150 mm spacing (mm²/m) | As at 200 mm spacing (mm²/m) |
|---|---|---|---|---|---|---|
| H10 | 10 | 78.54 | 0.617 | 785 | 524 | 393 |
| H12 | 12 | 113.10 | 0.888 | 1,131 | 754 | 566 |
| H16 | 16 | 201.06 | 1.578 | 2,011 | 1,340 | 1,005 |
| H20 | 20 | 314.16 | 2.466 | 3,142 | 2,094 | 1,571 |
| H25 | 25 | 490.87 | 3.853 | 4,909 | 3,272 | 2,454 |
| H32 | 32 | 804.25 | 6.313 | 8,043 | 5,362 | 4,021 |
| H40 | 40 | 1,256.64 | 9.865 | 12,566 | 8,378 | 6,283 |
Notes and Conditions of Use
- The library holds sizes H10 to H40 only; other sizes are not tabulated here.
- Mass per metre corresponds to the bar area multiplied by a steel density of 7,850 kg/m³.
- Crack-width limit used by the liquid-retaining tool when the EN option is selected: EN 1992-3 clause 7.3.1 tightness class 1, wk1 = 0.2 mm for hD/h up to 5 and 0.05 mm for hD/h of 35 or more, with linear interpolation between (as shown on slide 15 of the 2008 JRC Eurocodes workshop presentation on EN 1992-3). wk1 is a nationally determined parameter, so check the National Annex; the calculators make no pass/fail judgement on crack control under this option.
Frequently Asked Questions
How does effective depth enter the Eurocode 2 shear resistance of members without shear reinforcement?
EN 1992-1-1 clause 6.2.2(1) gives VRd,c = [CRd,c k (100 ρl fck)^(1/3)] bw d with k = 1 + sqrt(200/d), limited to 2.0, and d in mm, so k falls below 2.0 once d exceeds 200 mm. The expression is quoted here from the JRC Eurocode 2 worked examples (EUR 26566 EN, 2014) for reference only; it is not the shear check used by the liquid-retaining, box culvert, pile cap or counterfort wall calculators, which follow the Taiwan codes stated on their pages.
Which code do the linked calculators use?
The liquid-retaining structure, box culvert, pile cap and counterfort wall calculators design to the Taiwan codes stated on each tool page (the Taiwan concrete code follows the ACI 318-19 framework). The liquid-retaining tool can additionally report a direct crack width to EN 1992-1-1 clause 7.3.4 and EN 1992-3 clause 7.3.1. They are reference calculations and do not replace a design to the code required for your project.
Sources and disclaimer: values on these pages come from the platform's code-constants library, from producers' published section tables, or from the official publications named in each row. Rows that cite the UK Government GHG Conversion Factors contain public sector information licensed under the Open Government Licence v3.0. Standards (EN, BS) are cited by number only and their text is not reproduced. These pages are a design aid, not an official document; check the current source before use. Calculations must be checked and approved by a suitably qualified engineer.