Metric Ribbed Reinforcement Table (H10 to H40, B500B): Bar Area, Mass per Metre and Area per Metre Width

Nominal diameters, bar areas and masses are the values held in the platform's code-constants library for BS 4449:2005+A3:2016 Grade B500B bars (fyk = 500 MPa), the same constants used by the online tools. Area per metre width is the bar area divided by the bar spacing, rounded to the nearest mm²/m.

Reference table

→ Open the liquid-retaining structure design calculator (Taiwan concrete code; optional EN 1992 direct crack width)

BarNominal diameter (mm)Bar area (mm²)Mass (kg/m)As at 100 mm spacing (mm²/m)As at 150 mm spacing (mm²/m)As at 200 mm spacing (mm²/m)
H101078.540.617785524393
H1212113.100.8881,131754566
H1616201.061.5782,0111,3401,005
H2020314.162.4663,1422,0941,571
H2525490.873.8534,9093,2722,454
H3232804.256.3138,0435,3624,021
H40401,256.649.86512,5668,3786,283

Notes and Conditions of Use

  • The library holds sizes H10 to H40 only; other sizes are not tabulated here.
  • Mass per metre corresponds to the bar area multiplied by a steel density of 7,850 kg/m³.
  • Crack-width limit used by the liquid-retaining tool when the EN option is selected: EN 1992-3 clause 7.3.1 tightness class 1, wk1 = 0.2 mm for hD/h up to 5 and 0.05 mm for hD/h of 35 or more, with linear interpolation between (as shown on slide 15 of the 2008 JRC Eurocodes workshop presentation on EN 1992-3). wk1 is a nationally determined parameter, so check the National Annex; the calculators make no pass/fail judgement on crack control under this option.

Frequently Asked Questions

How does effective depth enter the Eurocode 2 shear resistance of members without shear reinforcement?

EN 1992-1-1 clause 6.2.2(1) gives VRd,c = [CRd,c k (100 ρl fck)^(1/3)] bw d with k = 1 + sqrt(200/d), limited to 2.0, and d in mm, so k falls below 2.0 once d exceeds 200 mm. The expression is quoted here from the JRC Eurocode 2 worked examples (EUR 26566 EN, 2014) for reference only; it is not the shear check used by the liquid-retaining, box culvert, pile cap or counterfort wall calculators, which follow the Taiwan codes stated on their pages.

Which code do the linked calculators use?

The liquid-retaining structure, box culvert, pile cap and counterfort wall calculators design to the Taiwan codes stated on each tool page (the Taiwan concrete code follows the ACI 318-19 framework). The liquid-retaining tool can additionally report a direct crack width to EN 1992-1-1 clause 7.3.4 and EN 1992-3 clause 7.3.1. They are reference calculations and do not replace a design to the code required for your project.