ASTM A615 Deformed Reinforcing Bar Sizes (#3 to #18): Diameter, Area, Weight, Area per Foot and Tension Development Length
Nominal diameters, bar areas and unit masses are the figures held in the platform's code-constants library for ASTM A615/A615M bars; weight per foot is the library mass converted from kg/m. Area per foot of width is the bar area times 12 in. divided by the spacing. The development length column is returned by the library's ACI 318-19 Table 25.4.2.3 function for the conditions listed in the notes.
Reference chart
| Bar size | Nominal diameter (in.) | Bar area (in²) | Weight (lb/ft) | As at 6 in. spacing (in²/ft) | As at 12 in. spacing (in²/ft) | Tension development length ld (in.) |
|---|---|---|---|---|---|---|
| #3 | 0.375 | 0.11 | 0.376 | 0.22 | 0.11 | 14.2 |
| #4 | 0.500 | 0.20 | 0.668 | 0.40 | 0.20 | 19.0 |
| #5 | 0.625 | 0.31 | 1.043 | 0.62 | 0.31 | 23.7 |
| #6 | 0.750 | 0.44 | 1.502 | 0.88 | 0.44 | 28.5 |
| #7 | 0.875 | 0.60 | 2.044 | 1.20 | 0.60 | 41.5 |
| #8 | 1.000 | 0.79 | 2.670 | 1.58 | 0.79 | 47.4 |
| #9 | 1.128 | 1.00 | 3.400 | 2.00 | 1.00 | 53.5 |
| #10 | 1.270 | 1.27 | 4.303 | 2.54 | 1.27 | 60.2 |
| #11 | 1.410 | 1.56 | 5.313 | 3.12 | 1.56 | 66.9 |
| #14 | 1.693 | 2.25 | 7.650 | 4.50 | 2.25 | 80.3 |
| #18 | 2.257 | 4.00 | 13.600 | 8.00 | 4.00 | 107.1 |
Notes and Limits of Applicability
- Development length conditions: Grade 60 bars (fy = 60,000 psi), normalweight concrete with f'c = 4,000 psi, casting position and epoxy factors of 1.0, and the Table 25.4.2.3 case in which the clear spacing and cover conditions are met (coefficient 25 for No. 6 and smaller bars, 20 for No. 7 and larger); the minimum is 12 in.
- For the other cases of Table 25.4.2.3 the lengths are 1.5 times the charted figures. Where the casting position factor (1.3) or the epoxy coating factor (1.2 or 1.5) applies, the length is multiplied by it; their product need not exceed 1.7.
- The coefficients are as implemented in the platform's calculation library; confirm them against the current edition of ACI 318 before use.
- Under that framework as held in the library, a Class B tension lap splice is 1.3 times the development length, and lap splices are not permitted for bars larger than No. 11 (clause 25.5.1.1).
- The weights per foot agree with the ASTM A615 inch-pound nominal weights printed by a producing mill (0.376 lb/ft for #3 through 13.60 lb/ft for #18).
Frequently Asked Questions
When does the ACI 318-19 one-way shear size effect factor reduce Vc?
Clause 22.5.5.1.3 gives lambda_s = sqrt(2 / (1 + d/10)), not greater than 1.0, with d in inches, for members with less than minimum shear reinforcement. The library function returns 1.000 at d = 10 in., 0.877 at 16 in., 0.791 at 22 in. and 0.659 at 36 in.
Can the charted development lengths be used directly in design?
Only for the stated conditions. A different bar grade, concrete strength, bar position, coating, cover or spacing changes the result, so compute the length for the actual conditions and confirm it against the governing code edition.
Sources and disclaimer: figures on these charts are drawn from the platform's code-constants library, from steel producers' published section data, or from the U.S. Government publications named beside each entry (FHWA, USDA, OSHA, FEMA, EPA and GSA). Naming a publication does not imply endorsement by any agency. Consensus standards (ACI, ASTM, AASHTO, AISC) are identified by designation only and none of their text is reproduced. The charts are a design aid rather than an official document, so confirm each figure against the current source. Engineering submittals remain the responsibility of the licensed professional engineer who seals them.