US Code Reference Notes: ACI 318-19 One-Way Shear Size Effect Factor and FHWA HEC-22 (4th Edition, 2024) Provisions
These notes list code expressions, the figures the platform's code library returns for them, and their sources. The coefficients are as implemented in the platform's calculation library; confirm them against the current edition of ACI 318 before use.
Summary table
| Topic | Expression or figures | Source |
|---|---|---|
| One-way shear size effect factor | lambda_s = sqrt(2 / (1 + d/10)), not greater than 1.0, with d in inches | ACI 318-19 clause 22.5.5.1.3, as held in the code library |
| Figures returned by the library function | d = 10 in.: 1.000; 12 in.: 0.953; 16 in.: 0.877; 20 in.: 0.816; 24 in.: 0.767; 30 in.: 0.707; 36 in.: 0.659; 48 in.: 0.587 | Library function for clause 22.5.5.1.3 |
| Where the factor applies | Members with less than minimum shear reinforcement; the framework permits neglecting it for one-way shallow foundations, two-way isolated footings, two-way combined footings and mat foundations | Table 22.5.5.1 and clause 13.2.6.2, as held in the code library |
| Rational Method drainage area | HDS-2 recommends application of the Rational Method to drainage areas smaller than 200 ac (80 ha) | FHWA HEC-22 (4th ed., 2024) section 4.2.2 |
| Storm drain velocity | Designers typically develop storm drains to maintain full-flow pipe velocities of 3 ft/s or greater | FHWA HEC-22 (4th ed., 2024) section 9.2.3 |
| HEC-22 edition status | The 3rd edition (FHWA-NHI-10-009, September 2009, revised August 2013) is archived and superseded by the 4th edition (FHWA-HIF-24-006, February 2024) | FHWA publication pages |
Notes and Limits of Applicability
- The retaining wall calculator checks stability to AASHTO LRFD Section 11 using the 9th Edition values published in FHWA GEC 11 and state DOT manuals (other editions are selectable), and reports a reinforced concrete table to ACI 318 with ASTM A615 Grade 60 bars.
- The counterfort wall, pile cap, box culvert and liquid-retaining calculators in this market are Taiwan-code reference calculations in SI units; each tool page states its basis.
Frequently Asked Questions
At what effective depth does lambda_s fall below 1.0?
For d greater than 10 in. in a member with less than minimum shear reinforcement. The library returns 0.877 at d = 16 in. and 0.707 at d = 30 in.
Does this page report rainfall increases between NOAA Atlas 14 and older data?
No. Any change depends on the location and has to be read from the NOAA data for the site, so no general percentage is given. The detention calculator takes rainfall intensity as a user input.
Sources and disclaimer: figures on these charts are drawn from the platform's code-constants library, from steel producers' published section data, or from the U.S. Government publications named beside each entry (FHWA, USDA, OSHA, FEMA, EPA and GSA). Naming a publication does not imply endorsement by any agency. Consensus standards (ACI, ASTM, AASHTO, AISC) are identified by designation only and none of their text is reproduced. The charts are a design aid rather than an official document, so confirm each figure against the current source. Engineering submittals remain the responsibility of the licensed professional engineer who seals them.