HyGeoWorks

US Code Reference Notes: ACI 318-19 One-Way Shear Size Effect Factor and FHWA HEC-22 (4th Edition, 2024) Provisions

These notes list code expressions, the figures the platform's code library returns for them, and their sources. The coefficients are as implemented in the platform's calculation library; confirm them against the current edition of ACI 318 before use.

Summary table

→ Open the retaining wall design calculator (AASHTO LRFD Section 11 with 9th Edition values, plus an ACI 318 design table)

TopicExpression or figuresSource
One-way shear size effect factorlambda_s = sqrt(2 / (1 + d/10)), not greater than 1.0, with d in inchesACI 318-19 clause 22.5.5.1.3, as held in the code library
Figures returned by the library functiond = 10 in.: 1.000; 12 in.: 0.953; 16 in.: 0.877; 20 in.: 0.816; 24 in.: 0.767; 30 in.: 0.707; 36 in.: 0.659; 48 in.: 0.587Library function for clause 22.5.5.1.3
Where the factor appliesMembers with less than minimum shear reinforcement; the framework permits neglecting it for one-way shallow foundations, two-way isolated footings, two-way combined footings and mat foundationsTable 22.5.5.1 and clause 13.2.6.2, as held in the code library
Rational Method drainage areaHDS-2 recommends application of the Rational Method to drainage areas smaller than 200 ac (80 ha)FHWA HEC-22 (4th ed., 2024) section 4.2.2
Storm drain velocityDesigners typically develop storm drains to maintain full-flow pipe velocities of 3 ft/s or greaterFHWA HEC-22 (4th ed., 2024) section 9.2.3
HEC-22 edition statusThe 3rd edition (FHWA-NHI-10-009, September 2009, revised August 2013) is archived and superseded by the 4th edition (FHWA-HIF-24-006, February 2024)FHWA publication pages

Notes and Limits of Applicability

  • The retaining wall calculator checks stability to AASHTO LRFD Section 11 using the 9th Edition values published in FHWA GEC 11 and state DOT manuals (other editions are selectable), and reports a reinforced concrete table to ACI 318 with ASTM A615 Grade 60 bars.
  • The counterfort wall, pile cap, box culvert and liquid-retaining calculators in this market are Taiwan-code reference calculations in SI units; each tool page states its basis.

Frequently Asked Questions

At what effective depth does lambda_s fall below 1.0?

For d greater than 10 in. in a member with less than minimum shear reinforcement. The library returns 0.877 at d = 16 in. and 0.707 at d = 30 in.

Does this page report rainfall increases between NOAA Atlas 14 and older data?

No. Any change depends on the location and has to be read from the NOAA data for the site, so no general percentage is given. The detention calculator takes rainfall intensity as a user input.